background image

Important Safety Instructions

2

2009 Electrolux Home Products, Inc.

All rights reserved.

 

 

NOTE:

This USE & CARE MANUAL provides specific operating instructions for your model. Use the portable air conditioner only as 

instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that 

may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance. 

WARNING

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any

other appliance. Read product labels for flammability and other warnings. 

WARNING

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,

follow basic precautions, including the following: 

Be sure the electrical service is adequate for the model you have chosen. This information

can be found on the serial plate, which is located on the side of the cabinet.
If the air conditioner is to be installed in a window, you will probably want to clean both

sides of the glass first.
Be sure the air conditioner has been securely and correctly installed according to the

installation instructions in this manual. Save this manual for possible future use in 

removing or reinstalling this unit. 

The complete electrical rating of your new protable air conditioner is stated on the serial 

plate. Refer to the rating when checking the electrical requirements. 

Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,

proper grounding is important. The power cord is equipped with a three-prong grounding

plug for protection against shock hazards.  
Your air conditioner must be used in a properly grounded wall receptacle. If the wall

receptacle you intend to use is not adequately grounded or protected by a time delay fuse

or circuit breaker, have a qualified electrician install the proper receptacle.  

Do not run air conditioner without outside protective cover in place. This could result in

mechanical damage within the air conditioner.  

Do not use an extension cord or an adapter plug.

WARNING

Electrical Information

WARNING

Avoid fire hazard or electric shock. Do not

use an extension cord or an adaptor plug. Do

not remove any prong from the power cord.

NOTE:

The power supply cord with
this air conditioner contains a current

detection device designed to reduce the risk

of fire.
Please refer to the section ‘Operation of

Current Device’ for details.

In the event that the power supply cord is

damaged, it cannot be repaired. It must be

replaced with a cord from the product

manufacturer.

Grounding type wall

receptacle

Do  not,  under  any

circumstances, cut,

remove, or bypass the

grounding prong.

Power supply cord

with 3-prong grounding

plug and current

detection device

SAFETY PRECAUTIONS

This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs.

Do not insert or place fingers or objects into the air discharge area on the front of the unit.

Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box.

Do not cut or damage the power cord.

If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.

In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized 

Electrolux servicer.

Do not operate the air conditioner with wet hands.

Do not pull on the power cord.

Do not drink any water that is drained from the air conditioner.

DANGER!  Avoid Serious Injury or Death 

Summary of Contents for FFPA0822R11

Page 1: ...00A03113 June 2009 Product Registration 4 Unit Description 5 Accessories Included 5 Installation Instructions 6 7 Important Safety Instructions 2 3 Air Conditioner Features 8 of your Portable Air Conditioner Operating Instructions 9 11 Care and Cleaning 11 Before You Call 12 Major Appliance Limited Warranty 13 Normal Sounds 4 ...

Page 2: ... be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an ad...

Page 3: ... READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER Unit must be upright for one hour prior to operating Plug in press RESET The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the following Plug in the Air Conditioner The power supply cord will have TWO buttons on the plug head Press the TEST button You will notice a c...

Page 4: ...mpany Normal Sounds Product Registration 4 Product Registration Normal Sounds 2009 Electrolux Home Products Inc All rights reserved 7RGD ಬV KLJK HIILFLHQF FRPSUHVVRUV PD KDYH D KLJK SLWFKHG FKDWWHU GXULQJ WKH FRROLQJ F FOH LJK SLWFKHG KDWWHU 8QLW PD YLEUDWH DQG PDNH QRLVH EHFDXVH RI XQHYHQ IORRU 9LEUDWLRQ 6RXQG RI 5XVKLQJ LU W WKH IURQW RI WKH XQLW RX PD KHDU WKH VRXQG RI UXVKLQJ DLU EHLQJ PRYHG E...

Page 5: ...e refer to the installation instructions for their usage PARTS PARTS NAME QUANTITY Exhaust hose Exhaust Adaptor A Exhaust Adaptor B Window Sliding Kit Foam Seal Remote Control Battery For remote control 1 pc 1 set 1 pc 1 pc 3 pcs 1 pc 1 pc 2 pcs 1 2 Screw 4 pcs 2 pcs 2 pcs 3 4 Screw 1 2 Hex Head Cap Screw Safety Lock Fig 1 CONTROL PANEL REMOTE CONTROL ROOM AIR DISCHARGE CASTOR CARRYING HANDLE BOTH...

Page 6: ...opening so that the warm exhaust air can be ducted outside First position unit on a flat floor and make sure there s a minimum of 12 clearance around the unit and is within the vicinity of a single circuit outlet power source The hose can be extended from its original length of 13 6 up to 59 but it is the best to keep the length to minimum required Also make sure that the hose does not have any sh...

Page 7: ...ider kit See Fig 17 Cut the adjustable window slider kit if the height of window is less than 26 6 inches Fig 12 6 Cut the foam seal to an appropriate length and seal the open gap between the sliding sash and outer window sash as shown in Fig 19 Fig 10 Foam seal A adhesive type Fig 16 Foam seal adhesive type Installation Instructions Installation Instructions Fig 19 Foam seal Fig 11 Window slider ...

Page 8: ...ith Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The RESET button is depressed when you want to return to the initial factory settings The LOCK button is depressed to lock the keypad so the settings canno...

Page 9: ...perating Instructions Operating Instructions You can set both delay stop and delay start by using the remote control while unit is in ON position or OFF position To set the delay stop timing first press TIMER OFF button on the Note This feature is unavailabe under FAN or DRY modes s feature can only be activated by using the remote control In this mode the selected temperature will increase by 2 F...

Page 10: ... drain location remove the bottom drain plug and let the water drain away Restart the machine until the P1 symbol disappears If error repeats call for service Operating Instructions During the dehumidifying mode you will need a garden hose sold separately to drain the condensate from the unit Remove the rubber stopper from the hose connector then screw on a garden hose to the connector as shown on...

Page 11: ...which behind the grill of the back panel Fig 26 Air Filter Cleaning Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry before replacing Or instead of washing you may vacuum the filter clean Replace the filter after the filter is dry If you plan to store the appliance during the winter ...

Page 12: ...et FAN speed to a faster setting to bring air through cooling coils more frequently Before You Call Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 60 F 16 C To defrost the coil set FAN ONLY mode O O Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Temperature is set to...

Page 13: ...IS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Servi...

Page 14: ......