Prepare Electrical Wiring
Electrical Requirements
1. This appliance must be supplied with 120V, 60 Hz.
and connected to an individual properly grounded
branch circuit, protected by a 15 or 20 ampere
circuit breaker or time delay fuse.
2. Wiring must be 2 wire with ground. (See Figure 2-5)
3. If the electrical supply does not meet the above
requirements, consult a licensed electrician before
proceeding.
Grounding Instructions - Cable Direct
This appliance must be connected to a grounded metal,
permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and
be connected to the equipment grounding terminal or
lead on the appliance.
Grounding Instructions - Power Cord
Models
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the
risk of electrical shock by providing a path of least
resistance for electric current. The plug must be
plugged into an appropriate outlet that is installed and
grounded in accordance with local codes and ordinances.
Power cords with plug must pass through a separate
hole.
NOTE
FOR PERSONAL SAFETY:
Remove house fuse or open circuit
breaker before beginning installation.
Do not use an extension cord or adapter
plug with this appliance.
WARNING
The improper connection of the
equipment grounding conductor can
result in a risk of electric shock. Check
with a qualified electrician or service
representative if you are in doubt that
the appliance is properly grounded.
WARNING
Cabinet Preparation & Wire Routing
1. The wiring may enter the opening from either side,
rear or floor within the shaded area.
2. Cut a 1-1/2” maximum diameter hole to admit the
electrical cable. The hole must be free of sharp
edges. If the cabinet wall is metal, the hole edge
must be covered with a bushing or grommet.
3. Cable direct connections may pass through the same
hole as drain hose and hot water line, if convenient.
If cabinet wall is metal, the hole edge must be
covered with a bushing or grommet.
Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher.
1. For cable direct connections the cable must be
routed as shown in Figure 2-5. Cable must extend a
minimum of 24” from the rear wall.
2. For power cord connections, install a 3-prong
grounding type receptacle. The power-supply
receptacle for the appliance must be installed in a
cabinet or on a wall adjacent to the undercounter
space in which the appliance is to be installed.