background image

9

Cleaning the air conditioner

Clean the surface of the unit with a damp cloth, then dry using 
a duster or similar.

!

CAUTION

Do not use chemical solvent (like benzene or alcohol) to clean the 
surface of the unit.  If you do so, the surface may be scratched, 
damaged or even cause the case to become deformed.

Prior to operating seasons

1.  Check to ensure that the air inlets and outlets of the unit 

are not blocked.

2.  Make sure that air 

fi

 lter is properly in place before operat-

ing the machine.  If the machine is operated with air 

fi

 lter 

removed, dust and foreign objects will result in faulty per-
formance of the air conditioner.

Preparation for storage

1.   Turn off the air conditioner, disconnect the power.

2.   Perform proper maintenance to the air 

fi

 lter and other parts.

3.  Open the base stopper to drain out all of the water from the 

base.  Operating the unit in fan only mode for 12 hours will 
help ensure there is no moisture within the unit.

4.   Cover the unit to prevent dust or 

fi

 lth from entering the unit.  

Safety Precautions

•  Make sure the unit is installed in an accessible location.

•   Do not locate the unit in direct sunlight so as to avoid discol-

oration of the plastic.

•  Do not use the unit in water or near water to avoid electrical 

shock.

•  Do not use near gas appliances, 

fi

 res or in the vicinity of 

fl

 ammable liquids.

•   Only operate the unit in the appropriate upright position.

!

CAUTION

!

WARNING

Power Sources

•  Do not use a damaged or improper AC socket.
•  When unplugging the unit, hold the power plug securely 

and pull it out carefully.

•   Never use an extension cord with this air conditioner.

Other Warnings

•   Keep the unit one meter away from TV sets or radios to 

avoid the risk of electromagnetic interference.

•   Ensure that the discharge air outlet is free from obstruc-

tions and not impeded by walls or other structures.

Maintenance /Service

•  Disconnect the power before cleaning.

•  Make sure there is no power to the unit before 

beginning to maintain or repair the unit in order 
to prevent accidents caused by electrical shock.

Cleaning the air filter

If the air 

fi

 lter is blocked with a lot of dust, the air 

fl

 ow volume 

will be reduced.  Clean the 

fi

 lter once every two weeks.

Open and clean the air 

fi

 lter:

1. Pull the 

fi

 lter out as shown in the drawing.

2.  Take out the air 

fi

 lter from the 

fi

 lter cover.

3.  Wash the air 

fi

 lter by immersing it gently into warm (about 

40°C or 104°F) water with a neutral detergent or vacuum 

the 

fi

 lter clean.

4. Rinse the 

fi

 lter and dry it thoroughly in a shaded place.

5.  Install the air 

fi

 lter back to its original place.

!

WARNING

Drain valve

Summary of Contents for ZoneAire P09A

Page 1: ...Portable Air Conditioner Models P09A and P12A Installation Operation Manual PAC IO 10 07...

Page 2: ...r unsafe prac tice which can result in severe personal injury or death This symbol refers to a hazard or unsafe prac tice which can result in personal injury or prod uct or property damage Table of Co...

Page 3: ...3 Unit Identification and Function 1 Control panel 2 Air outlet 3 Signal receptor 4 Handle 5 Caster 6 Air outlet hose 7 Air filter 8 Air intake hose 9 1 2 water outlet drain 10 Power supply cord...

Page 4: ...TO OPERATE AN AIR CONDITIONER TEST RESET Test Button Reset Button Control Panel Operation Mode control The mode control has three settings Cool Dehumidify and Fan The settings are adjusted with the M...

Page 5: ...revert back to room temperature Timer setting is available from 1 24 hours by pressing the button on Mode Control Press this button to change the operation mode in the order of Cool Dry Fan Farenheit...

Page 6: ...arts kit is packed with your unit in a separate carton Before you discard the packaging that your unit came in please locate the carton that contains these parts and ensure that all parts are present...

Page 7: ...window panel extensions 4 Close window 5 The window adapter kit should now fit securely within the window frame and you can now attach the air ex change tubes If you are having trouble attaching the...

Page 8: ...rnally the tank may become full If the tank becomes full the unit will turn off and the Water Full light will illuminate Draining Water The water can be drained from the unit by removing the base stop...

Page 9: ...se the unit in water or near water to avoid electrical shock Do not use near gas appliances fires or in the vicinity of flammable liquids Only operate the unit in the appropriate upright position CAUT...

Page 10: ...air filter Is SET TEMP suitable Set to a suitable temperature Is indoor fan speed set at low Set to a suitable fan speed Too much noise and vibration Is the sound part of the refrigeration cycle The...

Page 11: ...fuses 2 Products on which the model and serial numbers have been removed 3 Products which have defects or damage which results from improper installation wiring electrical current characteristics or m...

Page 12: ...PAC IO 10 07 Friedrich Air Conditioning Co Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4480 www friedrich com...