Dehumidifying and cooling operation

The operating range for cooling operation is 60°F - 90°F, 
and the operating range for dehumidifying is 68°F-88°F.

Power source

•  The AC socket must be 

fi

 rm and reliable.

•  Don’t connect the portable air conditioner to a multiple socket 

outlet which is also being used for other electrical appliances.

•  Insert the AC power plug securely into the AC socket before 

using the unit, when it beeps after two seconds, press ON/
OFF button, the unit begins to run.

LCDI power cord information

All Friedrich portable air conditioners are shipped from the 
factory with a Leakage Current Detection Interrupter (LCDI) 
equipped power cord. The LCDI device meets the UL and 
NEC requirements for cord connected air conditioners effec-
tive August 2004.
To test your power supply cord:
1.   Plug power supply cord into a grounded 3 prong outlet.
2.  Press RESET (See drawing below).
3.   Press TEST (listen for click; Reset button trips and pops out).
4.  Press and release RESET (listen for click; Reset button 

latches and remains on). The power supply cord is ready 
for operation.

NOTE: LCDI device is not intended to be used as a switch.
Once plugged in the unit will operate normally without the 
need to reset the LCDI device.
If the device fails to trip when tested or if the power supply 
cord is damaged it must be replaced with a new supply cord 
from the manufacturer. We recommend you contact our Tech-
nical Assistance Line at (800) 541-6645. To expedite service, 
please have your model and serial number available.

WARNING: NEVER 
CUT OR REMOVE 

THE GROUNDING 

PRONG FROM 
PLUG. NEVER USE 
EXTENSION CORDS 

TO OPERATE AN 
AIR CONDITIONER.

TEST

RESET

Test Button

Reset Button

Control Panel Operation

Mode control

The mode control has three settings– Cool, Dehumidify and 
Fan. The settings are adjusted with the Mode Control button. 
A light will indicate which setting is currently being used.

Cooling operation

1.  Press MODE button to choose the cooling mode, LCD 

window will show “cool”.

 

During the cooling operation, always place the air exhaust 
hose through an open window.    

2.  Repeatedly press TEMP+ or TEMP- button to set a proper 

room TEMP. between 60°F - 90°F. 

3.  Press FAN SPEED button to choose between low and high 

speeds.

NOTE:

In order to improve the cooling ef

fi

 ciency:

a)  If your room is directly exposed to the sun, draw the curtains.
b)  Do not place near other heat source.

Dehumidifying Operation

1.   Keep the windows and the doors closed to aid in effectively 

dehumidifying the room.

2.   Press MODE button to choose the dehumidifying mode, LCD 

window will show  “DRY”, the fan speed cannot be adjusted.

When used as dehumidi

fi

 er only it is not necessary to install 

the exhaust hose.

Time Set Function

To set the time to start the machine, with the unit off (but power 
supplied), press TIMER button, the LCD window will show “

”, continually press the TIMER button, set the preferred 

start time.  The setting range is 1-24 hours.
To set the time to stop the machine, with the unit running, 
press TIMER button, the LCD window will show “

”, con-

tinually press the TIMER button ,set the preferred time to stop 
the machine.  The setting range is 1-24 hours
NOTE: During timer mode if the TIMER button is pressed 
again it will cancel the timer operation.

Warning Light

Condensed water may accumulate in the unit. If the internal 
tank becomes full, the Warning Light will come on and the unit 
will not operate until the unit has been drained.

Summary of Contents for ZoneAire P09A

Page 1: ...Portable Air Conditioner Models P09A and P12A Installation Operation Manual PAC IO 10 07...

Page 2: ...r unsafe prac tice which can result in severe personal injury or death This symbol refers to a hazard or unsafe prac tice which can result in personal injury or prod uct or property damage Table of Co...

Page 3: ...3 Unit Identification and Function 1 Control panel 2 Air outlet 3 Signal receptor 4 Handle 5 Caster 6 Air outlet hose 7 Air filter 8 Air intake hose 9 1 2 water outlet drain 10 Power supply cord...

Page 4: ...TO OPERATE AN AIR CONDITIONER TEST RESET Test Button Reset Button Control Panel Operation Mode control The mode control has three settings Cool Dehumidify and Fan The settings are adjusted with the M...

Page 5: ...revert back to room temperature Timer setting is available from 1 24 hours by pressing the button on Mode Control Press this button to change the operation mode in the order of Cool Dry Fan Farenheit...

Page 6: ...arts kit is packed with your unit in a separate carton Before you discard the packaging that your unit came in please locate the carton that contains these parts and ensure that all parts are present...

Page 7: ...window panel extensions 4 Close window 5 The window adapter kit should now fit securely within the window frame and you can now attach the air ex change tubes If you are having trouble attaching the...

Page 8: ...rnally the tank may become full If the tank becomes full the unit will turn off and the Water Full light will illuminate Draining Water The water can be drained from the unit by removing the base stop...

Page 9: ...se the unit in water or near water to avoid electrical shock Do not use near gas appliances fires or in the vicinity of flammable liquids Only operate the unit in the appropriate upright position CAUT...

Page 10: ...air filter Is SET TEMP suitable Set to a suitable temperature Is indoor fan speed set at low Set to a suitable fan speed Too much noise and vibration Is the sound part of the refrigeration cycle The...

Page 11: ...fuses 2 Products on which the model and serial numbers have been removed 3 Products which have defects or damage which results from improper installation wiring electrical current characteristics or m...

Page 12: ...PAC IO 10 07 Friedrich Air Conditioning Co Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4480 www friedrich com...

Reviews: