background image

7

Installing the window adapter kit

Note: The window adapter kit must be installed and con-
nected for the air conditioner to work properly in Cool mode. 
The window adapter kit is not required when using the unit 
in Dehumidify or Fan modes.
Your window adapter kit has been designed to 

fi

 t most stan-

dard vertical and horizontal window applications. However, 
it may be necessary for you to modify some aspects of the 
installation procedures for certain types of windows.
1. Open window.
2.  Place window panel with extensions into windowframe 

and adjust to width of window. 

  Window adapter kit may be installed vertically aswell as 

horizontally. This installaton may also be used for crank 
style windows.

3.  Tighten the four screws on the window panel to secure 

the window panel extensions. 

4. Close window.
5. The window adapter kit should now 

fi

 t securely within 

the window frame and you can now attach the air ex-
change tubes. If you are having trouble attaching the air 
exchange tubes, you may attachthe tubes prior to install-
ing the window adapter kit.

Attaching the air exchange tubes to the air 
conditioner

1.  Attach the tubes to the window adapter kit.

2.  Attach the other end to the air conditioner. 

To attach air exchange tubes: push tube onto tube adapter 
and twist until the tab is in place in the hole on the tube.

To remove air exchange tubes: twist the end until the tab is 
clear of the hole in the tube and pull off.

Do not attach the tubes if using the unit in dehumidify 
mode.

Maintain a clear distance (from walls, furniture, etc.) 
of at least 10 inches around the unit to allow proper 
air circulation and prevent damage to the unit.

Important: Do not over-stretch the exhaust tube or-
make any unnecessary bends in it.

Summary of Contents for ZoneAire P09A

Page 1: ...Portable Air Conditioner Models P09A and P12A Installation Operation Manual PAC IO 10 07...

Page 2: ...r unsafe prac tice which can result in severe personal injury or death This symbol refers to a hazard or unsafe prac tice which can result in personal injury or prod uct or property damage Table of Co...

Page 3: ...3 Unit Identification and Function 1 Control panel 2 Air outlet 3 Signal receptor 4 Handle 5 Caster 6 Air outlet hose 7 Air filter 8 Air intake hose 9 1 2 water outlet drain 10 Power supply cord...

Page 4: ...TO OPERATE AN AIR CONDITIONER TEST RESET Test Button Reset Button Control Panel Operation Mode control The mode control has three settings Cool Dehumidify and Fan The settings are adjusted with the M...

Page 5: ...revert back to room temperature Timer setting is available from 1 24 hours by pressing the button on Mode Control Press this button to change the operation mode in the order of Cool Dry Fan Farenheit...

Page 6: ...arts kit is packed with your unit in a separate carton Before you discard the packaging that your unit came in please locate the carton that contains these parts and ensure that all parts are present...

Page 7: ...window panel extensions 4 Close window 5 The window adapter kit should now fit securely within the window frame and you can now attach the air ex change tubes If you are having trouble attaching the...

Page 8: ...rnally the tank may become full If the tank becomes full the unit will turn off and the Water Full light will illuminate Draining Water The water can be drained from the unit by removing the base stop...

Page 9: ...se the unit in water or near water to avoid electrical shock Do not use near gas appliances fires or in the vicinity of flammable liquids Only operate the unit in the appropriate upright position CAUT...

Page 10: ...air filter Is SET TEMP suitable Set to a suitable temperature Is indoor fan speed set at low Set to a suitable fan speed Too much noise and vibration Is the sound part of the refrigeration cycle The...

Page 11: ...fuses 2 Products on which the model and serial numbers have been removed 3 Products which have defects or damage which results from improper installation wiring electrical current characteristics or m...

Page 12: ...PAC IO 10 07 Friedrich Air Conditioning Co Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4480 www friedrich com...