TTJ-0197 (1/97)
(Page 17 of 64)
The overload is wired in series with the common motor
terminal. The overload senses both major amperage
and compressor temperature. High motor temperature
or amperage heats the disc causing it to open and break
the circuit to the common motor terminal.
Figure 3: External Overload
Heat generated within the compressor shell is usually
due to:
1.
High amperage.
2.
Low refrigerant charge.
3.
Frequent recycling.
4.
Dirty condenser.
TERMINAL OVERLOAD - TEST
(Compressor - External Type)
1.
Remove overload.
2.
Allow time for overload to reset before attempt-
ing to test.
3.
Apply ohmmeter probes to terminals on overload
wires. There should be continuity through the
overload.
TERMINAL OVERLOAD (Internal)
Some model compressors are equipped with an inter-
nal overload. The overload is embedded in the motor
windings to sense the winding temperature and/or cur-
rent draw. The overload is connected in series with the
common motor terminal.
Should the internal temperature and/or current draw be-
come excessive, the contacts in the overload will open,
turning off the compressor. The overload will automati-
cally reset, but may require several hours before the heat
is dissipated.
CHECKING THE INTERNAL OVERLOAD
(see Figure 4.)
Figure 4
INTERNAL OVERLOAD
1.
With no power to unit, remove the leads from the
compressor terminals.
2.
Using an ohmmeter, test continuity between ter-
minals C-S and C-R. If not continuous, the com-
pressor overload is open and the compressor must
be replaced.
FAN MOTOR
A single phase permanent split capacitor motor is
used to drive the evaporator blower and condenser
fan. A self-resetting overload is located inside the
motor to protect against high temperature and high
amperage conditions.
FAN MOTOR - TEST
1.
Determine that capacitor is serviceable.
2.
Disconnect fan motor wires from fan speed switch
or system switch.
3.
Apply “live” test cord probes on black wire and
common terminal of capacitor. Motor should run
at high speed.
Summary of Contents for YL24J35
Page 7: ...TTJ 0197 1 97 Page 7 of 64 COOLING LOAD ESTIMATE FORM...
Page 9: ...TTJ 0197 1 97 Page 9 of 64...
Page 14: ...Page 14 of 64 TTJ 0197 1 97...
Page 26: ...Page 26 of 64 TTJ 0197 1 97...
Page 27: ...TTJ 0197 1 97 Page 27 of 64...
Page 28: ...Page 28 of 64 TTJ 0197 1 97...
Page 29: ...TTJ 0197 1 97 Page 29 of 64...
Page 30: ...Page 30 of 64 TTJ 0197 1 97...
Page 31: ...TTJ 0197 1 97 Page 31 of 64...
Page 32: ...Page 32 of 64 TTJ 0197 1 97...
Page 33: ...TTJ 0197 1 97 Page 33 of 64...
Page 34: ...Page 34 of 64 TTJ 0197 1 97...
Page 35: ...TTJ 0197 1 97 Page 35 of 64...
Page 36: ...Page 36 of 64 TTJ 0197 1 97...
Page 37: ...TTJ 0197 1 97 Page 37 of 64 WIRING DIAGRAM FOR MODELS YS13J33 YM18J34A YL24J35...
Page 39: ...TTJ 0197 1 97 Page 39 of 64...
Page 40: ...Page 40 of 64 TTJ 0197 1 97...
Page 46: ...Page 46 of 64 TTJ 0197 1 97...
Page 47: ...TTJ 0197 1 97 Page 47 of 64...
Page 52: ...Page 52 of 64 TTJ 0197 1 97...
Page 53: ...TTJ 0197 1 97 Page 53 of 64...
Page 57: ...TTJ 0197 1 97 Page 57 of 64...
Page 58: ...Page 58 of 64 TTJ 0197 1 97...