61
PB
TROUBLESHOOTING
Electrical Troubleshooting Chart - Heat Pump
FIGURE 718 (TROUBLESHOOTING)
HEAT
PUMP
MODE
System
cools
when
heating
is
desired
Is
line
voltage
present
at
solenoid
valve?
Is
selector
switch
set
for
heat?
NO
Is
room
TSTAT
configured
for
B
signal?
YES
Configure
TSTAT
for
B
signal
NO
Is
the
solenoid
coil
good?
YES
YES
Replace
Solenoid
Coil
Is
the
reversing
valve
stuck?
Replace
Solenoid
Coil
NO
YES
YES