Low-energy ventilation unit 

with heat recovery

© Vallox
1.09.413E
14.5.2013

1  Extract air fan
2  Supply air fan
3  Post-heating radiator 

 

(electric 900 W) 

4  Heat recovery cell
5  Outdoor air fi lter F7
6  Outdoor air fi lter G4
7  Extract air fi lter G4
8  Automatic summer/winter damper
9  Safety switch
10  Measurement outlets 

 

(behind an opening door)

13  Control panel Digit SED
14  Carbon dioxide sensor (option)
15  Humidity sensor (option)

•   Can replace MUH-Ilmava 

100/120 from 1983–2004 

without ductwork alteration

Code 

A3560

Models

VALLOX 121 SE R

VALLOX 121 SE L

Electrical connection 

 

230 V, 50 Hz, 

 5.7 A

Degree of protection provided by enclosures 

IP 34

Fans direct current  Extract air  0.117 kW 0,9 A 

106 dm

3

/s 100 Pa

(DC) 

Supply air  0.117 kW 0,9 A 

104 dm

3

/s 100 Pa

Heat recovery 

 

 

Cross-counter fl ow cell, 

η

 >80 %

Heat recovery bypass 

 

Automatic

Electric post-heating unit (standard) 

900 W 3.9 A

Fans 

Supply air   

G4 and F7

 

Extract air   

G4

Weight 

 

 

60 kg

Ventilation power adjustment   

– Digit SED controller

 

 

 

– CO

2

 and %RH control

 

 

 

– remote monitoring control (voltage signal)

Options 

 

 

– CO

2

 sensor

 

 

 

– % RH sensor

TECHNICAL DATA

Operating, maintenance and technical instructions

10

13

14

15

1

2

3

4

5

6

8

7

9

The fi gure shows 

the R model

Vallox

121

SE

Summary of Contents for VALLOX 121 SE Series

Page 1: ...de A3560 Models VALLOX 121 SE R VALLOX 121 SE L Electrical connection 230 V 50 Hz 5 7 A Degree of protection provided by enclosures IP 34 Fans direct current Extract air 0 117 kW 0 9 A 106 dm3 s 100 Pa DC Supply air 0 117 kW 0 9 A 104 dm3 s 100 Pa Heat recovery Cross counter flow cell η 80 Heat recovery bypass Automatic Electric post heating unit standard 900 W 3 9 A Fans Supply air G4 and F7 Extr...

Page 2: ...ding to the highest measuring result 1 5 carbon dioxide sensors can be connected as options to the VALLOX 121 SE unit The adjustment is switched on off and if needed the setpoint 500 2000 ppm is set at the control panel The factory set ting is 900 ppm The recommended maximum carbon dioxide content in good indoor air is circa 1 000 ppm During control the control panel can be used to raise fan speed...

Page 3: ...amples of such situations are high humidity loads such as a swimming pool or a situation where the exhaust air duct has frozen through Remember Switch post heating off when it starts to get too warm in the dwelling because of warm weather Switch post heating on again when it gets cooler in autumn Post heating indicator light Maintenance reminder symbol Maintenance reminder The maintenance reminder...

Page 4: ...nu To settings menu see manual In order to move to the Settings menu press the and buttons simultaneous ly In the Settings menu you can chan ge setpoints for the ventilation unit 2 3 Week clock control Week program on Week clock control can be switched on with the button and off with the button Week clock control is on when the week clock control symbol is in the main display In week clock control...

Page 5: ...ctory settings can be restored by pressing the and buttons simultaneously Remember to ensure that the setpoints are in accordance with the factory settings for this unit 3 16 Choosing cascade adjustment for supply air temperature Cascade adjust off Cascade adjustment is chosen to be on or off with the and buttons 3 17 Choosing post heating for the unit Radiator type Electric rad A water or electri...

Page 6: ...fan speed 2 Sp 2 supply air temperature 17 C Temp 17 Move the cursor to the following hour Monday D 1 16 00 H 16 fan speed 4 Sp 4 supply air temperature 20 C Temp 20 Move the cursor to the following hour Monday D 1 19 00 H 19 fan speed 6 Sp 6 supply air temperature no change Temp N Move the cursor to the following hour Monday D 1 21 00 H 21 fan speed 4 Sp 4 supply air temperature no change Temp N ...

Page 7: ... by pulling carefully Place a thin sheet board or paper under the fan in order to prevent the bottom tank from being scratched when removing the fan Unfasten the fixing screw of the fan H hex socket head cap screw AV 4 mm and place the fan on the bottom tank Rotate the fan R model anticlockwise L model clockwise and slide the fan along the bottom tank Unfasten the quick couplings of the fan wires ...

Page 8: ...tes at speed 1 check the fan speed Wiring fault in the carbon dioxide sensor in the control panel or in the humidity sensor or the cable is of the wrong type Contact a maintenance company The connections have to be checked and corrected if necessary 9 Freezing alert message is displayed and the unit is stopped Antifreeze of the water circulating radiator is active NOTE If there is no non freezing ...

Page 9: ...ded operating range Volume flow rate Sound power level in supply air duct one duct by octave band LW dB Sound power level in extract air duct one duct by octave band LW dB ADJUSTMENT POSITION AIR FLOW dm3 s ADJUSTMENT POSITION AIR FLOW dm3 s Adjustment position 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Air flow dm3 s 25 7 41 5 51 0 53 9 58 8 75 6 78 8 101 0 29 5 41 3 43 8 51 9 60 8 70 7 75 3 96 0 Medium fre...

Page 10: ...t R2 Post heating radiator M Damper motor 24 VAC Wire colours s blue m black r brown va white vi green p red h grey kv yellow green 16 V 0 V 0 V 230 V 7023500 2011 11 17 JK M1 GND A B PWM1 PWM2 S RH2 S RH1 L N NO NC 90 C 130 C R2 L N L r N N L L1 L2 L3 N1 L4 NC GND PWM 1 s s r r s s kv kv p p k k HK 0 10V DC A B M S S 1 2 S S RH1 RH2 12x0 25mm 3184600 PWM 2 r s s kv kv r r h h 5 10 3 1 NOL R r s T...

Page 11: ...ake sure that its address is 1 If control panels have the same address they go to bus fault state In this case remove one of the control panels and change the address of the other panel The above mentioned situation can arise in connection with the later installation of an additional control panel External electrical connection Vallox 121 SE code A3560 METAL M WHITE 2 B ORANGE 2 A WHITE 1 ORANGE 1...

Page 12: ...g water connections The delivery includes a Silent Kick water seal By connecting a pipe to the water seal the water condensing from extract air can be led to a floor drain not directly to the drain Silent Klick water seal prevents the sound caused by water as the water seal dries up The pipe must not rise after the water seal The condensation water discharge outlet is located at the rear edge in t...

Reviews: