73
PB
INSTALLATION
How To Connect
19
How To Connect
IMPORTANT: Please read following electrical safety data carefully.
1. Remove front panel. See Figure 22.
2.
Remove junction box.
•
Remove junction box cover by removing three screws from
front. Remove junction box by taking out top, rear and side
screws. See Figure 25.
WARNING
Electrical Shock and/or Unit
Operation and Damage Hazard
Failure to follow this warning could result in
personal injury or death and/or unit damage.
●
●
●
●
●
●
●
Follow the National Electrical Code (NEC)
or local codes and ordinances.
For personal safety, this unit
MUST BE
properly grounded.
Protective devices (fuses or circuit breakers)
acceptable for unit installations are specified
on the nameplate of each unit.
Do not
use an extension cord with this unit.
Aluminum wiring in the building may present
special problems - consult a qualified
electrician.
When unit is in STOP position, there is
still voltage to the electrical controls.
Disconnect power to unit before servicing by:
1. Removing power cord (if it has one) from
wall receptacle.
2. Removing branch circuit fuses or turning
circuit breakers off at panel.
FRP017
UNIT
CONNECTOR
JUNCTION BOX
JUNCTION BOX COVER
High
Med
Low
Fan
Cool
Heat
Fan Speed
Mode
Temperature
Power
Figure 25
Junction Box Location
Figure 26
Power Connection
FRP018
ACCESSORY
POWER SUPPLY CORD
OR HARD WIRE
High
Med
Low
Fan
Cool
Heat
Fan Speed
Mode
Temperature
Power
3. Connect accessory power supply cord or hard wire connector to
unit connector. See Figure 26.
•
Units must be installed using the appropriate power supply
kit. See Table 2 --POWER CONNECTION CHART. These
connections must be followed.
See Table 2 on page 14 for power cord accessory options and ratings.
4.
Reinstall junction box and cover.
•
Use wire clamp to attach power cord to basepan. Secure
with screws (included) See Figure 27.
•
Replace junction box and cover with screws removed from
Step 2. Tighten securely.
5. Replace front panel. See Figure 24.
6. Connect power to unit.
Figure 27
Wire Clamp
FRP019
WIRE CLAMP
High
Med
Low
Fan
Cool
Heat
Fan Speed
Mode
Temperature
Power