General Instructions 

Read these instructions carefully before 
installation and use. Keep this manual for 
future reference.

The product may only be used as set out in 
the assembly and operating instructions. The 
guarantee is only valid if the product is used 
in the manner intended and in accordance 
with the instructions. 

 

Application area 

AGI is a robust air curtain intended for 
vertical or horizontal installation in large 
doorways such as logistic centres, loading 
bays and warehouses. Recommended 
installation height  AGI4500: 4,5 m and 
AGI6000: 6 m. The air curtain is available 
without heat and with water heating.  
Protection class: IP54.  

Operation 

Air is drawn in at the top/rear of the unit and 
blown out downwards/outwards so that it 
shields the door opening and minimizes heat 
loss. To achieve the optimum air curtain effect 
the unit must extend the full height/width of 
the door opening.

The grille nearest the door is adjustable and 

is normally angled outwards to achieve the 
best protection against incoming cold air. 

The efficiency of the air curtain depends 

on the air temperature, pressure differences 
across the doorway and any wind pressure.

 

NOTE! Negative pressure in the building 

considerably reduces the efficiency of the air 
curtain. The ventilation should therefore be 
balanced. 

 

Mounting

The air curtain range includes variants for 
horizontal and vertical installation. See 
dimension drawings.  
 

Horizontal mounting

The air curtain is installed horizontally with 
the supply air grille facing downwards as close 
to the door as possible. The unit is suspended 
from the ceiling by threaded rods. For the 
protection of wider doorways, several units 
can be mounted next to each other.  

Electrical installation  

The installation, which should be preceded by 
an omnipolar switch with a contact separation 
of at least 3 mm, should only be wired by a 
competent electrician and in accordance with 
the latest edition of IEE wiring regulations.  
    Control (400V3~) is connected to the 
terminal block in the junction box. The cable 
glands used must meet the protection class 
requirements. See wiring diagrams. 
  

Connecting the water coil (W)

The installation must be carried out by an 
authorised installer. 

The water coil has copper tubes with 

aluminium fins and is suitable for connection 
to a closed water heating system. The heating 
coil must not be connected to a mains 
pressure water system or an open water 
system. 

Note that the unit shall be preceded by a 

regulating valve, see Frico valve kit.  
The water coil is connected via connections 
with dimensions as given in the table 
(see diagram) on the side of the unit. The 
connections to the heating coil must be 
equipped with shut off valves to allow problem 
free removal.  

Adjustment of the air curtain and air flow 

The direction and speed of the air flow should 
be adjusted considering the load on the 
opening. Pressure forces affect the air stream 
and make it bend inwards into the premises 

Vertical mounting

The air curtain is mounted vertically as close 
as possible to the door. For the best effect air 
curtains should be placed on both sides of the 
opening.  
The unit can be turned and positioned on 
either side of the door. The air curtain is 
mounted on a floor frame which is included. 
The edging is attached horizontal to the floor 
using fasteners appropriate for the surface. 
See Fig.2. 

Two units can be mounted directly on top 

of each other, they are fastened together with 
supplied fastening plates. The air curtain 
must be secured to wall or ceiling.

All manuals and user guides at all-guides.com

Summary of Contents for AGI4500

Page 1: ...AGI4500 6000 Original instructions 18 SE 21 GB 24 NO 27 FR 31 DE 35 ES 39 NL 43 IT 47 PL 51 RU All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...bersetzung der verwendetenTexte in englischer Sprache siehe die entsprechenden Sprachseiten DE Las p ginas introductorias contienen b sicamente im genes Consulte la traducci n de los textos en ingl s...

Page 3: ...4515 1500 AGI4520 2000 AGI4525 2500 AGI4530 3000 L 300 135 135 255 195 430 80 640 486 185 245 80 10 25 465 1 5 m 4 x M10 2 2 5 3 m 6 x M10 640 430 640 486 25 10 625 50 465 L Vertical mounting Horizont...

Page 4: ...0 4 L mm AGI6012 1200 AGI6018 1800 AGI6024 2400 AGI6030 3000 L 2 25 25 25 25 AGI6012 AGI6018 AGI6024 737 5 25 25 25 25 737 5 737 5 737 5 AGI6030 L 2 25 25 25 25 AGI6012 AGI6018 AGI6024 737 5 25 25 25...

Page 5: ...75 75 575 25 300 300 485 185 730 160 50 75 75 575 25 300 AGI6000 Fig 1c AGI4500 6000 5 L mm AGI6012 1200 AGI6018 1800 AGI6024 2400 AGI6030 3000 2 Inside thread AGI6012 6018 6024 DN25 1 AGI6030 DN32 1...

Page 6: ...me Fig 3 Minimum distance A mm B mm C mm D mm AGI4500 251 625 215 432 AGI6000 296 717 260 524 AGI4500 6000 6 min 300 mm A C D 18 96 5 B 50 13 2X4 All manuals and user guides at all guides com a l l g...

Page 7: ...14 RTRDU7 T10S RTI2 AGB304 MDC MDCDC Controls VRS20 DN20 VRS25 DN25 TVVS20 DN20 TVVS25 DN25 SD20 GP1010 RTI2 T10S AGI W RTRD3 5 2 7 RTRD14 AGB304 MDC RTRDU Level 1 1 2 Level 2 2 SD20 AV20 25 TRVS20 25...

Page 8: ...PE U V TK W TK PE Fan 2 Fan 3 Fan 4 Fan 5 M 3 PE L1 L2 L3 5 6 6 5 6 5 6 5 6 5 AGI 13 14 AGB To terminals L1 L2 and L3 in slave units Bridge RT RT if no door contact is used To terminals 5 6 in slave u...

Page 9: ...W TK PE Fan 2 Fan 3 Fan 4 Fan 5 M 3 PE L1 L2 L3 5 6 6 5 6 5 6 5 6 5 230V A B 2 4 4 t C 6 2 7 T10S 13 14 AGB 1 2 3 KRT1900 To terminals L1 L2 and L3 in slave units Bridge RT RT if no door contact is us...

Page 10: ...TRDU 230V 230V 400V3N Number of fans AGI4515 AGI6012 2 AGI4520 AGI6018 3 AGI4525 AGI6024 4 AGI4530 AGI6030 5 To terminals L1 L2 and L3 in slave units To terminals 5 6 in slave units AGI AGI4500 6000 1...

Page 11: ...AGI4500 6000 230V3 connected only for 230V3 AGI AGI4500 6000 11 Convertible 400V3 230V3 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 12: ...62 41 0 52 4 5 74 38 0 9 13 Supply water temperature 60 C Room temperature 18 C Outlet air temperature 35 C 1 Water temperature 60 40 C Room temperature 18 C Type Fan position Airflow m3 h Output kW...

Page 13: ...Max 7300 42 49 5 0 26 1 12 58 41 8 0 72 7 9 AGI4525WH Max 9100 52 46 0 29 1 58 74 42 0 9 10 4 AGI4530WH Max 10900 63 47 0 36 1 85 90 42 5 1 1 16 1 Supply water temperature 80 C Room temperature 18 C O...

Page 14: ...1 26 9 5 Supply water temperature 60 C Room temperature 18 C Outlet air temperature 35 C 1 Water temperature 60 40 C Room temperature 18 C Type Fan position Airflow m3 h Output kW Return water temp C...

Page 15: ...0 39 3 5 70 9 39 6 0 87 16 AGI6024WH Max 12600 72 7 52 0 0 47 3 4 94 39 9 1 15 18 4 AGI6030WH Max 15600 90 9 52 0 0 58 2 1 118 2 40 2 1 45 11 8 Supply water temperature 80 C Room temperature 18 C Outl...

Page 16: ...oil for high water temperature 580 C Horizontal mounting IP54 2 Water heat AGIV4500 WH coil for high water temperature 580 C Vertical mounting IP54 Horizontal mounting Vertical mounting Type Output 5...

Page 17: ...e motor A Length mm Weight kg AGIH6012A 0 6600 85 69 400V3 2 0 1200 51 AGIH6018A 0 9600 87 71 400V3 2 8 1800 75 AGIH6024A 0 12600 88 72 400V3 3 7 2400 97 AGIH6030A 0 15600 89 73 400V3 4 7 3000 120 Typ...

Page 18: ...several units can be mounted next to each other Electrical installation The installation which should be preceded by an omnipolar switch with a contact separation of at least 3 mm should only be wired...

Page 19: ...er unnecessary Service repairs and maintenance For all service repair and maintenance disconnect the power supply for all connections Maintenance Since fan motors and other components are maintenance...

Page 20: ...be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction...

Page 21: ...co AB Tel 46 31 336 86 00 Box 102 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se All manuals and user guid...

Reviews: