![Frico AGI4500 Original Instructions Manual Download Page 15](http://html1.mh-extra.com/html/frico/agi4500/agi4500_original-instructions-manual_2332182015.webp)
AGI4500/6000
15
Output charts water AGI6000WH
*
1
) Recommended outlet air temperature for good comfort and optimized output.
*
2
) Nominal output at given supply and return water temperature.
Supply water temperature:110 °C
Room temperature: +18 °C
Outlet air temperature: +35 °C*
1
Water temperature: 110/80 °C
Room temperature: +18 °C
Type
Fan
position
Airflow
[m
3
/h]
Output
[kW]
Return
water
temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
Output *
2
[kW]
Outlet
air temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
AGI6012WH Max
6600
37,3
47,0
0,15
0,9
57,9
43,7
0,48
7,9
AGI6018WH Max
9600
56,5
47,0
0,22
1,2
87,4
44,7
0,72
10,9
AGI6024WH Max
12600
71,2
44,0
0,27
1,2
115,9
45
0,95
12,5
AGI6030WH Max
15600
88,6
44,0
0,33
0,7
145,7
45,4
1,20
8
Supply water temperature:90 °C
Room temperature: +18 °C
Outlet air temperature: +35 °C*
1
Water temperature: 90/70 °C
Room temperature: +18 °C
Type
Fan
position
Airflow
[m
3
/h]
Output
[kW]
Return
water
temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
Output *
2
[kW]
Outlet
air temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
AGI6012WH Max
6600
37,5
54,0
0,26
2,5
47
38,9
0,58
11,6
AGI6018WH Max
9600
56,7
54,0
0,39
3,5
70,9
39,6
0,87
16
AGI6024WH Max
12600
72,7
52,0
0,47
3,4
94
39,9
1,15
18,4
AGI6030WH Max
15600
90,9
52,0
0,58
2,1
118,2
40,2
1,45
11,8
Supply water temperature:80 °C
Room temperature: +18 °C
Outlet air temperature: +35 °C*
1
Water temperature: 80/60 °C
Room temperature: +18 °C
Type
Fan
position
Airflow
[m
3
/h]
Output
[kW]
Return
water
temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
Output *
2
[kW]
Outlet
air temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
AGI6012WH Max
6600
37,2
58,0
0,40
6,0
38,7
35,2
0,47
8,1
AGI6018WH Max
9600
56,2
58,0
0,61
8,4
58,4
35,8
0,71
11,2
AGI6024WH Max
12600
74,7
58,0
0,81
9,7
77,5
36
0,95
12,9
AGI6030WH Max
15600
88,1
54,0
0,82
4,1
97,4
36,3
1,19
8,2
Supply water temperature:82°C
Room temperature: +18 °C
Outlet air temperature: +35 °C*
1
Water temperature: 82/71 °C
Room temperature: +18 °C
Type
Fan
position
Airflow
[m
3
/h]
Output
[kW]
Return
water
temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
Output *
2
[kW]
Outlet
air temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
AGI6012WH Max
6600
38,0
58,0
0,39
5,5
45,4
38,2
1,01
34,6
AGI6018WH Max
9600
55,7
56,0
0,52
6,2
68,5
38,9
1,53
47,5
AGI6024WH Max
12600
71,6
54,0
0,62
5,9
90,8
39,1
2,02
54,2
AGI6030WH Max
15600
89,7
54,0
0,78
3,7
114,3
39,5
2,55
34,9
See www.frico.se for additional calculations.
All manuals and user guides at all-guides.com