![Frico AGI4500 Original Instructions Manual Download Page 14](http://html1.mh-extra.com/html/frico/agi4500/agi4500_original-instructions-manual_2332182014.webp)
AGI4500/6000
14
Output charts water AGI6000WL
Supply water temperature: 80 °C
Room temperature: +18 °C
Outlet air temperature: +35 °C*
1
Water temperature: 80/60 °C
Room temperature: +18 °C
Type
Fan
position
Airflow
[m
3
/h]
Output
[kW]
Return
water
temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
Output *
2
[kW]
Outlet
air temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
AGI6012WL Max
6600
38,8
38,0
0,23
6,3
55,1
42,5
0,67
47,8
AGI6018WL Max
9600
56,4
40,0
0,35
2,4
77,5
41,7
0,95
15,7
AGI6024WL Max
12600
71,6
38,0
0,42
2,8
103,6
42,1
1,26
21,2
AGI6030WL Max
15600
90,7
38,0
0,53
1,9
130,1
42,4
1,59
14,6
Supply water temperature: 70 °C
Room temperature: +18 °C
Outlet air temperature: +35 °C*
1
Water temperature: 70/50 °C
Room temperature: +18 °C
Type
Fan
position
Airflow
[m
3
/h]
Output
[kW]
Return
water
temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
Output *
2
[kW]
Outlet
air temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
AGI6012WL Max
6600
37,2
41,0
0,31
11,4
43,9
37,5
0,53
31,3
AGI6018WL Max
9600
55,4
44,0
0,52
5,1
61,6
36,8
0,75
10,2
AGI6024WL Max
12600
73,8
44,0
0,69
7,0
82,3
37,1
1,00
13,9
AGI6030WL Max
15600
93,0
44,0
0,87
4,7
103,4
37,4
1,26
9,5
Supply water temperature: 60 °C
Room temperature: +18 °C
Outlet air temperature: +35 °C*
1
Water temperature: 60/40 °C
Room temperature: +18 °C
Type
Fan
position
Airflow
[m
3
/h]
Output
[kW]
Return
water
temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
Output *
2
[kW]
Outlet
air temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
AGI6012WL Max
6600
39,4
50,0
0,96
96,0
32,5
32,5
0,39
18,1
AGI6018WL Max
9600
55,4
50,0
1,35
31,7
45,5
31,9
0,55
5,9
AGI6024WL Max
12600
74,1
50,0
1,80
42,7
60,7
32,1
0,74
8
AGI6030WL Max
15600
93,0
50,0
2,26
29,5
76,5
32,4
0,93
5,4
Supply water temperature: 55 °C
Room temperature: +18 °C
Outlet air temperature: +35 °C*
1
Water temperature: 55/35 °C
Room temperature: +18 °C
Type
Fan
position
Airflow
[m
3
/h]
Output
[kW]
Return
water
temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
Output *
2
[kW]
Outlet
air temp.
[°C]
Water
flow
[l/s]
Pressure
drop
[kPa]
AGI6012WL Max
6600
37,3
50,0
2,01
404,9
26,8
29,9
0,32
12,7
AGI6018WL Max
9600
54,7
53,0
5,89
565,0
37,3
29,4
0,45
4,1
AGI6024WL Max
12600
73,2
53,0
7,89
728,4
49,6
29,6
0,60
5,6
AGI6030WL Max
15600
88,3
50,0
4,76
126,1
62,7
29,8
0,76
3,8
*
1
) Recommended outlet air temperature for good comfort and optimized output.
*
2
) Nominal output at given supply and return water temperature.
See www.frico.se for additional calculations.