background image

Page 42

Service Manual TDRac

PKII

 USA   form 9120931  rev. 09/2022

Level 1

Level 2

Level 3

Drain time

Option to set the drain time when demo mode is activated

Supply time 1 Option to set the (water) Supply time when demo mode is activated

demo clean start

Option to start a demo clean cycle

auto off time

Option to swith off the rotisserie automaticly after the set time when not operated. When set 

to "no" the rotisserie will not be switched off automatically. 

change pin

Option to change the manager pin code

Drain duration

Sets the open time for the drain valve and backflush valve

Fat drain

Option to controll the fat drain by the recipe or default open

Clean Cycles

Sets the number of repeated clean cycles during  cleaning

Clean temperature temp 1

Set clean temperature during cycle 1

temp 2

Set clean temperature during cycle 2

temp 3

Set clean temperature during cycle 3

Soap safe 

temp

Sets the "safe" temperature to cool down to before soap can be added to the oven at the 

beginning of the cleaning cycle.

Cooling temp Set temperature to cool down to before the cleaning starts

Clean Times

Hot rinse time Set time for hot rinse step in cleaning cycle
Rinse time

Set time for rinse step in cleaning cycle

Drain time

Set time for drain open step in cleaning cycle

Flush time

Set time for flush step in cleaning cycle

Drain back-

flush time

Set time for drain backflush step in cleaning cycle

Final time

Set time for final step in cleaning cycle

Shine rinse 

time

Set time for shine rinse step in cleaning cycle

Clean water 

supply

supply time 1

Set time 1 for filling the oven with clean water

supply time 2

Set time 2 for filling the oven with clean water

add water 

interv. 

Interval time for adding water during cleaning

add water 

time

set time for water adding during cleaning

Clean sanitation

sanitation 

step

Option to able or enable a sanitation step

sanitation 

time

Set time for sanitation step in cleaning cycle

sanitation 

temp

Set temperature during the sanitation step

Deep clean warn-

ing

Number of cook cycles after which you receive a deep clean warning

Daily clean warn-

ing

Number of cook cycles after which you receive a daily warning

Force cleaning

Option to enable a forced cleaning

Quick clean

Option to enable a Quick clean cycle

Daily clean

Option to enable a Daily clean cycle

Descale setting

Option to set the Descale cycle in a full / short cycle or to disable the descale cycle

Delete all pro-

grams

Option to delete all recipes from the controller

Summary of Contents for TDR auto-clean Series

Page 1: ...assing If you have not attended a training for this product you should read in its entirety the repair procedure you wish to perform to determine if you have the necessary tools instruments and skills...

Page 2: ...Page 2 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY PAGE EMPTY PAGE...

Page 3: ...4 Creating a cooking program 25 Editing a cooking program 25 Example of error message 26 Audio volume and sound setting 26 Page 3 Service Manual TDRacPKII USA form 9120931 rev 09 2022 Versions Version...

Page 4: ...58 Measuring the Rotor drive motor 59 Measuring the PT1000 sensor 59 Measuring the motor valve 60 Measuring the Pump 60 Service procedures 61 Access to service parts TDR ac 61 Access to service parts...

Page 5: ...ntill 100104166 114 TDR7 ac Parts list sheet metal untill 100104166 115 TDR7 ac Underframe untill 100104166 116 TDR7 ac Parts list Underframe untill 100104166 117 TDR7 7 ac extra parts untill 10010416...

Page 6: ...0 84 Weight Gross lbs 662 1059 Net lbs 552 948 Maximum ambient temperature F 95 95 Sound pressure dB A 70 70 Electrical installation Voltage V 3 208 3 208 Frequency Hz 50 60 50 60 Required power kW 12...

Page 7: ...TDR ac Installation Page 7 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY PAGE EMPTY PAGE...

Page 8: ...hering of the unit Connect the water Connect drain Grease collection Make a test run on 220 C 425 F Give instructions to the operator UNPACKING THE UNIT Immediately after unpacking the oven check for...

Page 9: ...k 4x Place the ramps in front of the pallet and fasten them Tilt the unit slightly and remove the front beam Tilt the unit the other way and remove the beam at the back Carefully roll the unit onto th...

Page 10: ...unit in a clear visible manner ELECTRICAL SUPPLY IMPORTANT Make sure you lea ve sufficient space around the ro tisserie to easily remove or insert the rotor If the base has rotating wheels the floor...

Page 11: ...cture typically either wall or floor to limit the movement of the appliance and thus helping to prevent damage to the conduit during cleaning maintenance and service operations A tether bracket as sho...

Page 12: ...DRAIN CONNECTIONS TDR7 8 AC The Power water and drain connections can be found on the back of the unit POWER WATER AND DRAIN CONNECTIONS TDR7 7 AC TDR8 8AC The Power water and drain connections can b...

Page 13: ...e reduction of silica and other non dissolved sedi ments Water hardness and descaling filters 7 A descaling filter is advised when the hardness of the water is 4 dH 4 Grains Gal 8 A descaling filter i...

Page 14: ...mples An extraction hood is prescribed when the unit is NOT delivered with the special Fri Jado Exhaust Hood mounted on it The TDR8 produces about 10 m 350 cf vapour during a cooking cycle When placin...

Page 15: ...on or service calls INSTRUCTIONS FOR OPERATORS The oven must be burned in to release any odours that might result from heating the new oven surfaces Operate the oven at maximum temperature setting of...

Page 16: ...8 100 4 50 2 6 1 2 3 6 6 50 2 1270 50 1420 56 935 36 7 8 TDR ac Installation Page 16 Service Manual TDRacPKII USA form 9120931 rev 09 2022 Location of mains connection Location of water connectionG 3...

Page 17: ...81 1 4 1865 73 3 8 1690 66 1 2 820 32 1 4 710 27 15 16 121 1 2 3 149 5 5 7 8 25 1 557 22 123 4 13 16 TDR ac Installation Page 17 Service Manual TDRacPKII USA form 9120931 rev 09 2022 Location of mains...

Page 18: ...300 12 6 50 2 110 4 1 4 1230 48 1 2 1470 58 895 35 1 4 TDR ac Installation Page 18 Service Manual TDRacPKII USA form 9120931 rev 09 2022 TDR 7 8 AC ON STAND Location of mains connection Location of w...

Page 19: ...470 58 1830 72 895 35 1 4 1930 76 1755 69 1 8 149 5 5 7 8 123 4 13 16 650 25 5 8 25 1 TDR ac Installation Page 19 Service Manual TDRacPKII USA form 9120931 rev 09 2022 TDR 7 8AC WITH HOOD Location of...

Page 20: ...12 6 80 3 1 8 1490 59 1570 62 1720 68 600 23 1 2 1235 48 5 16 1000 39 3 8 8 9 TDR ac Installation Page 20 Service Manual TDRacPKII USA form 9120931 rev 09 2022 Location of mains connection Location of...

Page 21: ...B C D B TDR ac Installation Page 21 Service Manual TDRacPKII USA form 9120931 rev 09 2022 A Power connection B Water connection 3 4 C Grease drain D Waste water drain hose pillar 3 4 EMPTY PAGE EMPTY...

Page 22: ...anual TDRacPKII USA form 9120931 rev 09 2022 Footprint dimensions seen from above Driptray Driptray Support Space for intake cooling air TDR 7 8 AC ON COUNTER A Power connection B Water connection 3 4...

Page 23: ...enu Help menu under construction Clean screen Locks the touch screen for 60 seconds About Gives information about soft and hard ware Screenshot Only available with a wifi connec tion The manager pin c...

Page 24: ...he door Push The below 4 steps are only applicable in case the cooking program has a pre heat step Program running Push to see actual tem perature Pause button A short sound comes when going into the...

Page 25: ...name Chose or change step name if applicable Drag up for an extra cooking step Chicken Other name if applicable Grilling Chicken Edit Recipe Grilling Chicken Chicken Cooking Create Recipe EDITING A C...

Page 26: ...e heard in combination with Test audio AUDIO VOLUME AND SOUND SETTING EXAMPLE OF ERROR MESSAGE Example motor failure during cooking In the log menu the er ror can be found Select the error Meta data i...

Page 27: ...ool down first Place the detergent Push to pause if appli cable Push to continue Cleaning program has finished Now it is asked to place the detergent Follow the instructions that can be found in the c...

Page 28: ...ling Soapcooling Sanitationtime 20 min Clean start Addcleaner Wait Start delay Quick Clean Soapsafe temp 75 C Cooling temp 75 C Clean temp 1 40 C Clean temp 2 60 C Flush time 10 sec Drainbackflushtime...

Page 29: ...e position during cooking The pictures below show each stage in the cleaning pro gram Tubes in red are flowing Pump or valves in yellow are active open Soap has to be added after stage 1 The first cyc...

Page 30: ...Q4 P2 P2 Page 30 Service Manual TDRacPKII USA form 9120931 rev 09 2022 Rinse B right 10 sec Drain B 10 sec Drain B 120 sec Pause 60 sec Drain 180 sec Rinse B left 10 sec The stage 3 and 4 are rehears...

Page 31: ...pictures below show each stage in the cleaning pro gram Tubes in red are flowing Pump or valves in yellow are active open Soap has to be added after stage 1 The first cycle is following stage 1 untill...

Page 32: ...acPKII USA form 9120931 rev 09 2022 Rinse B right 10 sec Drain B 10 sec Drain B 120 sec Pause 60 sec Drain 180 sec Rinse B left 10 sec The stage 3 and 4 are rehearsing alternately during 1 minute each...

Page 33: ...available inputs and also which contacts are closed J13 shows that the door is closed J14 shows an open ther mistor in the blower cau sing a blower error Digital outputs is showing the available outp...

Page 34: ...the con troller The existing recipes will be overwritten Copies i control recipes from the USB drive to the controller The current recipes will be overwritten Copies recipes from the USB drive to the...

Page 35: ...e screencomes back 4 The following messages appear The software comes in a zip file The name cor responds with the version of the software For example V1_00_3 zip 1 Extract the zip file 2 Copy or move...

Page 36: ...Time will be deducted in case of A smaller load A warmer load defrosted Higher mains voltage Note that In case the time or temperature will be changed in the cooking program the heat number will be ad...

Page 37: ...Eco function no no yes Audio Audio setting 1 1 11 Audio factor 100 1 100 Test audio Sound set Marimba Marimba Bell Beeper key board beep on on off Filter capacity 50 30000 or for infinite Lime filter...

Page 38: ...5 min Shine rinse time 10 min 1 30 min Clean water supply supply time 1 45 sec 1 120 supply time 2 45 sec 1 120 add water interv 15 min 1 60 add water time 2 sec 1 30 Clean sanitation sanitation step...

Page 39: ...et the outputs Test program no yes Ignore errors no no yes save HACCP save haccp log on usb HACCP days 10 1 99 save params on USB save parameters on usb save params from USB load parameters from usb I...

Page 40: ...no yes Pump Reset Pump time no yes Start End Counters started recipes ended recipes started quick clear ended quick clean started daily clean ended daily clean started full descale ended full descale...

Page 41: ...e key board Filter capacity Option to set the actual filter capacity of the used water filter system in relation to the water quality on site Set if no filter is installed Lime filter Shows the remain...

Page 42: ...in cleaning cycle Rinse time Set time for rinse step in cleaning cycle Drain time Set time for drain open step in cleaning cycle Flush time Set time for flush step in cleaning cycle Drain back flush t...

Page 43: ...eatup is activated it will cool down first Heat up time reset Resets the recorded heatup times Lights out Option to disable or enable the interiour lights during the cook Wifi Smartphone Optin to allo...

Page 44: ...the cook corrections total Output Coun ters Shows hours of heater activation Resets the heater counter Shows hours of blower activation Resets the blower counter Shows hours of rotor activation Resets...

Page 45: ...3 options operate program settings Select the program by pushing the corresponding key Within the program menu the user can edit or add additional cooking pro grams The cooking programs can be pin co...

Page 46: ...l TDRacPKII USA form 9120931 rev 09 2022 CLEANING PROGRAM TDRAC An overview of the various steps of the cleaning program Go to Settings service The amount of time of the various steps can be adjusted...

Page 47: ...01 00 Last error Firmware version of the I O board MFMB v1 00 Manager The manager settings are used to change local settings like tem perature date time or to load recipes A complete overview can be f...

Page 48: ...with a pin code The system will not ask for a pin code if the default 0000 value is being used You can view the program pin code via settings service pin code Error history Read out Save on USB stick...

Page 49: ...ed Go to settings service I O test All switched electrical parts can be tested via TEMB outputs Go to settings service I O test TEMB outputs See next page for an overview of connectors and relays Note...

Page 50: ...8 R9 R10 R11 R12 R13 J2 R1 J2 4 R3 J2 3 R2 J2 1 R4 J2 6 R6 J31 R12 J61 R7 J33 R9 J42 R8 J41 R11 J52 R10 J51 P1 P2 W1 K2 M2 K1 M1 W2 102 103 W2 WATER VALVE R5 J32 102 103 96 98 94 95 W2 2 pumps system...

Page 51: ...o be set to the right de vice type TDRac 2 Connect the USB drive 1 Disconnect the mains supply 3 Connect the mains supply 5 Disconnect the USB drive 4 The following messages appear After extracting Th...

Page 52: ...Page 52 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY PAGE EMPTY PAGE...

Page 53: ...eheat delta 0 50 C to 50 C or 90 F to 90 F Auto recipe start yes no yes Buzzer set 0 0 4 key beep yes no yes water capacity filter 50 30000 or for infinite Lime filter Remaining capacity of lime filte...

Page 54: ...time 3 min 1 15 Final time 2 min 1 15 min Clean rinse time 10 min 1 30 min Clean water supply supply time 1 45 sec 1 120 supply time 2 45 sec 1 120 add water interv 15 min 1 60 add water time 2 sec 1...

Page 55: ...1 120 sec Rinse heat 40 min Rinse heat time 5 40 min Temperature 140 F Clean temp 2 77 140 Rinse cold 10 min Rinse time 5 40 min Draining Drain time 3 min Drain time 2 10 min Rinsing Rinse cold drain...

Page 56: ...Page 56 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY PAGE EMPTY PAGE...

Page 57: ...Moist can go in and the insulation resistance can go down Therefore it is good to measure this insulation resistance before mounting it In case this Insulation resistance is too low it could be consid...

Page 58: ...t the highest position The capacitor is now charged with 500VDC Leave it for a few seconds and then put the wires together A loud spark must arise If not the ca pacitor is leaking loosing its charge I...

Page 59: ...the resistance overview for the PT1000 sensors F PT1000 4 921 6 14 960 9 32 1000 50 1039 68 1077 9 77 1097 4 86 1116 7 F PT1000 104 1155 4 122 1194 140 1232 4 158 1270 176 1308 9 194 1347 212 1385 230...

Page 60: ...Electrical tests Page 60 Service Manual TDRacPKII USA form 9120931 rev 09 2022 Valve position closed in this view Pull to open manual Ccw open Cw close MEASURING THE PUMP Pressure switch 2 Amp at free...

Page 61: ...panel and the blower panel on the inside to reach the blower motor and the heating element 1 CPU LCD board and key board 2 Power I O board 3 Speaker 4 Lamp connection 5 Cooling fans 6 PT 1000 tempera...

Page 62: ...USA form 9120931 rev 09 2022 Top view Inside view with removed blower panel Close up view of water inlet valves and drain valves TDR5ac TDR7ac 23 Blower motor 24 5 pole socket plug connection of blow...

Page 63: ...RVICE PARTS STACKED UNITS 32 Waste water pump upper unit 33 Waste water pump lower unit 34 Double soleno d valve water inlet 35 Heated grease drain hose 36 Thermostat for heated drain hose 36 Drain he...

Page 64: ...SERVICE PROCEDURES Page 64 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY PAGE EMPTY PAGE...

Page 65: ...ine from the shaft A puller is delivered with the new blower kit 5 Unscrew 3 screws 6 Pull off the shaft seal with pressure plate 7 Disconnect the blower wiring 8 Unscrew 4 nuts 9 Take out the motor M...

Page 66: ...e seal is sticking Loosen the mounting disc from the ceiling 3 Turn the assembly a little to the right hold it steady and let it come down 4 Disconnect the 5 pole plug Mounting the blower assembly Thi...

Page 67: ...r nut with an open end spanner 4 Unscrew 6 nuts M6 5 Take out the pressure plate 6 Remove the blower panel 7 Unscrew the M4 nuts that secure the hea ting element to the ceiling This is 3 pcs in a TDR7...

Page 68: ...s from the mounting plate 4 Hold the heating element or pull it down when the gasket sticks 5 Note the wiring number and write down if necessary 6 Disconnect the wiring Note Hold the rear nut with an...

Page 69: ...erial number 100075954 1 Remove the side panel at the operator panel side 2 Mark the position of the motor on the bracket 3 Take the rotor shaft out of the cooking cavity 4 Unscrew the 5 bolts from th...

Page 70: ...receptacles mounted then these have to be cut off and the wires stripped Note that the white wire marked A is longer 4 Hook in the rotor and check the axial play This should be 2 5 3mm 3 32 4 32 5 Pu...

Page 71: ...lime filter needs to be replaced and in the manager menu the parameter lime filter replaced needs to be put on yes The maximum amount of water has been used and a new filter cartridge needs to be pla...

Page 72: ...parameters Wrong cooking program Hi Limit thermostat triggered Hi limit thermostat triggered due to transport hi vibrations Defective hi limit thermostat Defective temperature sensor temp too high Bad...

Page 73: ...transport operator Hinge loose Leakage of steam at the door Door not right adjusted Light does not switch off Power stays on the lamps Contactor malfunction contacts sticking Oven cavity fills up with...

Page 74: ...on the right place Wrong amount detergent Drain issue Sewer drain malfunction Q5 Drain hose not installed properly Grease drain malfunction Q4 cleaning proces started while unit is still loaded with o...

Page 75: ...il ling time is too long Wiring Check the wiring Element malfunction Check the current with AC current tester Safety ther mostat Contactor does not switch on after starting of program Wiring Check the...

Page 76: ...g process Broken capacitor Check repace capacitor Seal of drive motor shaft Grease leaking Seal deteriorated Replace seal Be sure that the motor shaft comes through the center of the hole properly all...

Page 77: ...more keys don t function Check flat cable connection between CPU board and keypad touch screen Do a hard reset Replace key pad or CPU board Keypad touch screen has bad reaction Difficult to ope rate...

Page 78: ...Check wiring and plugs sockets on the I O board Valve does not open durng rinsing Motor valves left and right rinse See below over view Q2 Q3 No water comes out of the spray ers Both valves stay close...

Page 79: ...TROUBLE SHOOTING Page 79 Service Manual TDRacPKII USA form 9120931 rev 09 2022 HYDRAULIC OVERVIEW Suction filter Descaling filter By pass on zero Suction filter 2 pumps system 1 pump system Descaling...

Page 80: ...8 26 25 23 23 88 866 832 45 5 6 7 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 51 21 12 6 F 9310099 48 48 92 i control s control 35 17 16 TDR5 ac TDR7 8 ac A2 A1 4 11 2 12 3 14 42 43 49 A2 A1 4 11 2 12 3...

Page 81: ...tch 2 2 24 9312081s Heating element 10 8kW 208V 2 2 25 9291012 USB cable 0 26 9191222 End Clamp Clipfix 35 5 PHX 10 27 9310156s Mains terminal block PT10 1 31 9191218 Fuse holder Euro ABB 2 32 9172425...

Page 82: ...4 35 36 37 38 39 1 5 4 6 1 1 1 5 6 7 8 1 3 2 2 1 46 58 57 60 59 63 62 65 66 64 67 70 73 72 71 68 79 81 80 2x 1x 69 450 mm 17 3 4 51 74 75 76 77 1 0 9 0 m m 55 56 9291172 78 82 Page 82 Service Manual T...

Page 83: ...9 Plug 3p outputs 64 9291170 Plug 5p power 65 9291174 Plug 2p output 66 9291173 Plug 6p outputs 67 9310851s Wire repair set 24V outputs 2 68 9310852s Wire repair set 208V outputs 2 69 9310816s Connect...

Page 84: ...TDR 5 TDR 8 TDR 8 8s ac s control TDR 5 TDR 8 TDR 8i ac i control 85 TDR 5 TDR 8 99 98 99 97 97 99 97 Page 84 Service Manual TDRacPKII USA form 9120931 rev 09 2022 TDRAC CONTROL PANELS TDR 7i ac i con...

Page 85: ...e L R ass TDR8 1 0 0 control panels 3 92 9318534s Operator panel ass TDR8 s Right contr 1 2 93 9318535s Operator panel ass TDR8 s Left contr 1 2 94 9318536s Operator panel ass 8 8 s Right contr 1 2 95...

Page 86: ...912 137 137 123 135 136 151 155 107 912 138 128 128 139 125 897 124 956 140 140 154 150 106 128 101 5 100 5 105 5 104 5 103sb 5 102 5 109 108 118 5 118 5 153 152 103 5 110 111 110 111 Page 86 Service...

Page 87: ...152 9318517s Ass Inner door Left turning TDR8ac from 100095332 untill 100104166 1 2 153 9318519s Ass Inner door Right turning TDR8ac from 100095332 untill 100104166 1 2 Inner doors TDR8 8 ac untill 1...

Page 88: ...13 14 14 163 48 166 167 896 822 834 822 834 162 163 164 165 161 160 13 14 14 163 48 166 167 896 822 834 822 834 168 169 13 163 164 163 170 176 171 5 185 185 185 185 Page 88 Service Manual TDRacPKII US...

Page 89: ...1110 Connector 2 pole ceramic 2 160 9314113 Cover lamp 2 161 9314114 Mounting bracket lamp fixture 2 162 9312054 Seal top 2 163 9312055 Seal light for lamp 500W 2 1 164 9312020 Glass oven illumination...

Page 90: ...920 832 209 208 207 834 Untill serial number 100089663 213 220 TDR5 ac TDR8 ac 202 TDR5 TDR8 230 234 231 232 237 235 236 233 238 206 216 205 216 Page 90 Service Manual TDRacPKII USA form 9120931 rev...

Page 91: ...or TDR7ac 1 2 207 9294649 Pressure ring 6 holes 1 untill ser nr 100089663 208 9292244 Shaft seal 6 holes 1 untill ser nr 100089663 209 9294650 Reinforcement ring 6 holes 1 untill ser nr 100089663 210...

Page 92: ...al TDRacPKII USA form 9120931 rev 09 2022 TDR7AC BLOWER HEATING FROM SERIAL NR 100105707 257 256 255 262 30 265 261 260 266 263 822 894 267 268 979 837 273 805 12 6 F 29 30 12 6 F 894 804 254 253 976...

Page 93: ...le 253 9312082 Gasket heating element 5 holes 1 2 254 9314528 Pressure plate heating element 1 255 9312018 Seal Fan suspension 1 1 256 3702325 Shaft seal 1 1 257 9294007 Pressure ring 1 260 9314139 Re...

Page 94: ...79 979 269 837 837 273 252 805 805 271 12 6 F 12 6 F 40 41 12 6 F 894 264 273 804 254 253 976 24 275 275 17 1 24 1 251 251 TDR8ac 100104166 TDR8ac TDR8 8ac 255 279 959 280 289 959 280 Page 94 Service...

Page 95: ...t 6 holes 1 2 253 9312082 Gasket heating element 5 holes 1 2 254 9314528 Pressure plate heating element 1 255 9312018 Seal Fan suspension 1 1 256 3702325 Shaft seal 1 1 257 9294007 Pressure ring 1 258...

Page 96: ...2 309 310 376 373 364 363 362 361 365 360 318 315 309 21 316 308 327 328 47 319 324 317 317 345 348 346 49 371 314 350 349 314 325 316 318 22 20 20 399 303 310 303 304 312 351 50 378 374 373 374 373 3...

Page 97: ...lding nipple 3 4 1 325 9310401s Suction filter 1 2 326 9313026 Plug 1 2 327 9191203 Water supply hose 1 328 9191227 Gasket 24x 16x2 1 1 329 9301031 Elbow threaded 3 4 F M BSP 1 331 9314435 Deep clean...

Page 98: ...1 311 311 312 341 379 370 314 327 328 47 319 324 317 317 345 348 349 314 350 346 216 353 354 847 1700 mm 300 mm 180 mm 364 363 362 361 365 360 329 TDR5ac Location of parts in TDR5 ac may differ 359 37...

Page 99: ...Bend 90 threaded 1 2 M M SS 1 324 9301006 Welding nipple 3 4 1 325 9310401s Suction filter 1 2 326 9313026 Plug 1 2 327 9191203 Water supply hose 1 328 9191227 Gasket 24x 16x2 1 1 329 9301031 Elbow th...

Page 100: ...407 409 412 414 411 413 416 402 415 417 420 418 419 421 422 423 401 409 408 412 210 410 864 804 812 877 430 23 871 23 890 890 890 890 805 805 805 805 826 834 Page 100 Service Manual TDRacPKII USA for...

Page 101: ...Page 101 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY PAGE EMPTY PAGE...

Page 102: ...438 439 442 441 443 446 432 447 450 449 451 452 453 439 438 442 448 440 445 432 864 804 812 877 424 354 460 23 871 23 890 890 890 890 805 805 805 805 826 834 424 Page 102 Service Manual TDRacPKII USA...

Page 103: ...9314455 Top panel TDR7ac 1 438 9314402 Mounting strip TDR7ac 2 439 9314403 Front back panel TDR7ac 2 440 9314060s Cooling air guide ass TDR7ac 1 441 9314482 Reinforcement beam R top TDR7ac 1 442 93104...

Page 104: ...1 480 482 479 475 478 486 481 493 491 490 492 488 484 487 476 477 493 480 478 489 492 483 498 471 497 495 496 494 471 472 472 497 Page 104 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY P...

Page 105: ...Page 105 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY PAGE EMPTY PAGE...

Page 106: ...77 483 480 482 486 492 477 480 492 483 471 472 498 495 494 471 472 489 501 503 500 502 501 502 504 504 508 510 512 505 507 509 511 511 513 513 Page 106 Service Manual TDRacPKII USA form 9120931 rev 09...

Page 107: ...ruction beam 2 502 9314300 Drawer support 2 503 9314008 Back panel 1 504 9314327 Panel small 2 505 9314004 Side panel R 1 507 9314301 Drawer 1 508 9314011 Locking profile 1 509 9314420s Door 1 510 931...

Page 108: ...11 424 542 536 534 533 532 531 530 541 540 535 539 538 537 893 532 539 531 982 981 531 542 Page 108 Service Manual TDRacPKII USA form 9120931 rev 09 2022 TDR7 AC OPEN UNDERFRAME AND CLADDING FROM 1001...

Page 109: ...9070840 Grommet 23 mm 511 9314320 Drip tray 530 9310488s Welded frame 531 9190177 Castor ass 532 9314603s Side panel L R ass 533 9314610s Rear Panel ass 534 9344117 Center panel 535 9314611 Bottom 536...

Page 110: ...560 558 556 561 559 557 554 552 550 555 553 551 550 471 472 471 472 50 74 75 76 77 Page 110 Service Manual TDRacPKII USA form 9120931 rev 09 2022 TDR7 7 AC EXTRA PARTS...

Page 111: ...065 Swivel castor 2 472 9172066 Swivel castor with brake 2 550 9314465 Construction beam 2 551 9314456 Top plate stacked lower unit 1 552 9314459 Top cover stacked lower unit 1 553 9314562 Heating pla...

Page 112: ...611 413 612 613 604 606 607 602 603 610 263 603 354 46 23 615 23 871 618 406 617 430 440 890 890 890 890 805 805 805 805 826 834 Page 112 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY P...

Page 113: ...Page 113 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY PAGE EMPTY PAGE...

Page 114: ...2 633 624 626 627 622 623 630 263 623 354 46 23 635 23 871 638 406 637 460 440 352 356 890 890 890 890 805 805 805 805 826 834 Page 114 Service Manual TDRacPKII USA form 9120931 rev 09 2022 TDR7 AC SH...

Page 115: ...ide panel TDR7ac 2 624 9314133 Reinforcement bracket top left TDR7ac 1 625 9314132 Reinforcement bracket left TDR7ac 1 626 9314135 Reinforcement bracket top right TDR7ac 1 627 9314134 Reinforcement br...

Page 116: ...51 650 502 483 652 652 662 507 655 665 657 502 654 665 666 424 668 669 513 513 660 939 939 495 496 445 483 498 471 472 Page 116 Service Manual TDRacPKII USA form 9120931 rev 09 2022 TDR7 AC UNDERFRAME...

Page 117: ...9314300 Drawer support 2 507 9314301 Drawer 1 651 9314305 Side panel left underframe 1 652 9314315 Bracket underframe 2 653 9314308 Back panel underframe 1 654 9314311 Gutter drip water 2 655 9314310...

Page 118: ...03 707 710 9310204 714 560 713 717 711 716 704 703 703 703 702 9310203 9310206 671 672 721 720 525 723 724 722 672 671 715 Page 118 Service Manual TDRacPKII USA form 9120931 rev 09 2022 TDR7 7 AC EXTR...

Page 119: ...back frame 1 706 9314507 Lower front frame 1 707 9314538 Position plate hose 1 710 9310462 Rear beam underframe 1 711 9310463 Front beam underframe 1 713 9314522 Tray guide left 1 714 9314519 Tray gui...

Page 120: ...751 757 753 445 486 488 750 762 476 490 489 424 492 494 497 471 497 472 495 496 483 498 471 472 476 963 832 963 963 832 487 481 481 482 Page 120 Service Manual TDRacPKII USA form 9120931 rev 09 2022 E...

Page 121: ...Page 121 Service Manual TDRacPKII USA form 9120931 rev 09 2022 EMPTY PAGE EMPTY PAGE...

Page 122: ...7 302 303 315 309 316 318 315 21 21 21 21 308 308 318 316 316 316 323 323 316 325 321 320 313 313 20 336 2x 337 2x 332 330 130 316 309 308 311 311 311 312 312 805 896 896 341 375 4x 379 2x 340 372 327...

Page 123: ...SS 4 311 9311018 Hose clamp 19 21 mm 6 312 6000032 Hose clamp 26 38 mm 2 313 9301108 Hose 13x23 2 2 m 314 9311028 Reducing bushing 3 4 x1 2 SS 315 9311009 Union conicle 1 2 M F SS 3 316 3721047 Hexago...

Page 124: ...ecess pan head 858 0141075 Screw M3x16 SS Cross recess pan head 859 4312810 Socket set screw M3x6 SS 861 4285151 starlock washer 6mm Pos Part nr Description 862 9191041 Circlips E type for 6mm shaft 8...

Page 125: ...0197807 Screw M4x30 slotted ZP 954 4285084 Screw 4 8x19 ZP Self drilling and tapping 955 9008217 Blind rivet 4x8 6 956 9174680 Washer 5 2x 20x2mm 957 4285047 nut M8 hexagon thin DIN 439B 958 0195783 S...

Page 126: ...1000 J8 1 J8 2 Option Hood Hi limit A1 A2 36 200 61 201 W2 102 103 88 89 K3 A2 94 95 A1 3 P3 K3 97 SEWER PUMP 96 98 SEWER PUMP option Not in bottom unit of stacked device 99 11 10 92 93 DRAIN HEATER o...

Page 127: ...alve 10 ltr min R4 J2 6 K2 illumination R3 J2 3 M2 blower R2 J2 1 K1 heating R1 J2 4 M1 rotor J62 J61 J52 J51 J42 J41 J33 J32 J31 Bu Ye Rd Q3 Q4 Q1 Q2 Q5 82 90 88 89 76 P1 W1 K2 M2 K1 M1 FANcontrol J1...

Page 128: ...1 1 1 1 Signal Signal 5 Vdc Gnd Gnd J16 J17 J3 J4 J5 J6 J33 J31 J41 J51 J61 J32 J42 J52 J62 J7 J11 PWR R7 R6 R8 R10 R12 R5 R9 R11 R13 R4 R2 R1 R3 J13 J15 analog digital red white 203 202 flow detecti...

Page 129: ...Signal Signal 5 Vdc Gnd Gnd J16 J17 J3 J4 J5 J6 J33 J31 J41 J51 J61 J32 J42 J52 J62 J7 J11 PWR R7 R6 R8 R10 R12 R5 R9 R11 R13 R4 R2 R1 R3 J13 J15 analog digital red white 203 202 flow detection 205 2...

Page 130: ...ow 204 205 PT 1000 J8 1 J8 2 Option Hood Hi limit A1 A2 36 200 61 201 W2 102 103 88 89 K3 A2 94 95 A1 3 P2 K3 97 96 98 SEWER PUMP option Not in bottom unit of stacked device 99 11 10 92 93 DRAIN HEATE...

Page 131: ...2 spray right R7 J33 Q5 drain sewer and or P2 sewer pump R6 J31 W2 Water solenoid valve R5 J32 W1 water solenoid valve 10 ltr min R4 J2 6 K2 illumination R3 J2 3 M2 blower R2 J2 1 K1 heating R1 J2 4 M...

Page 132: ...5 34 S3 ROTOR option S3 2 1 21 22 WATER VALVE SEWER DRAIN J31 1 2 3 J32 1 2 J33 1 2 3 J41 1 2 3 J42 1 2 3 J51 1 2 3 J52 1 2 3 J61 1 2 3 J62 1 2 3 YE RD BU YE RD BU YE RD BU YE RD BU YE RD BU PWR IN J2...

Page 133: ...49 K1 Heating 21 10 12 11 60 61 19 20 79 71 69 45 L N 3 X5 37 63 56 58 70 21 22 W1 P1 Q1 Q4 Q5 Q3 Q2 WATER VALVE R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 J2 R13 J62 NC R12 J61 P1 pump R11 J52 Q3 sp...

Page 134: ...TDRacPKII USA form 9120931 rev 09 2022 Fri Jado Inc 1401 Davey Road Suite 100 Woodridge IL 60517 USA fax 1 630 689 1424 us info frijado com www frijado com USA toll free 877 FRI JADO For technical sup...

Reviews: