PROGRAMMING INSTRUCTIONS
Page 15
Page 15
Service Manual Bake Star intelligent
PKII
form 9123665 rev. 06/2013
Level 1
Level 2
Level 3
Default
Possibilities
Pulse timing
t1
5 sec.
0,1 - 120
T2
3 sec.
1 - 10
T3
0,1 sec.
(Japan 0,2
sec)
0,1 - 1
fan values
Fan speed right
T9
45 sec.
10 - 90
Fan speed left
T10
45 sec.
10 - 90
Fan Pause
T11
3 sec.
1 - 90
Fan cool speed
3
1 - 5
fan S times
Fan S speed right
T12
10
10 - 90
Fan S speed left
T13
10
10 - 90
Fan S pause
T14
15
10 - 90
Fan S speed
3
1 - 5
manual ope-
ration
no
yes - no
correct-factor
3x
1x - 10x
debug rs232
no
no - yes
demo mode
no
no - yes
auto off
60
no or 10 - 240
pin code
****
read out of the manager pin code
Sensor offset
0 °C
-5°C - 5°C
complete
cleaning
yes
no - yes
delete all
programs
no - yes
edit clean
prog
special
see table below
PID factors
P
100
0 - 100
I
5
0 - 100
D
100
0 - 500
iMax
100
10 - 300
Relay actions:
80
16 - 160
Energy
Volts
230
1 - 260
Model
BS-I5
BS-I3 - BS-I5 - BS-I8 - BS-I10
Pressure
no
no - yes
I/O test
read the inputs and set the outputs
Ignore errors
no
no - yes
Cleaning program
step time temp blower steam exhaust
1
5
50
1
1 10
closed
2
30
70
1
1 30
closed
3
5
40
5
3 |
closed
4
5
60
5
0 -
closed
5
-
0
-
0 -
closed
6
-
0
-
0 -
closed
7
-
0
-
0 -
closed
8
-
0
-
0 -
closed
9
-
0
-
0 -
closed
CLEANING PROGRAM BS-I
The cleaning program is adjustable
in the service menu!
Enter parameter “edit clean prog”
Summary of Contents for BS10i