SERVICE PROCEDURES
Page 20
Service Manual Bake Star intelligent
PKII
form 9123665 rev. 06/2013
• The door opens and closes normally, but the blowers keep on turning when the door is
opened.
The microswitch came loose or is defect. The CPU does not “see” then, that the door
has opened. In case of a BSp or a BSi (2006 model) it is even so that at the end of the
baking program it is not possible anymore to control the keyboard because the CPU
is waiting for the “door open” signal. Then the customer’s only possibility is to pull the
plug after which he can bake another session.
-->Replace the door lock.
• The door does not open.
`
The gasket is not pushing hard enough against the door.
-->Adjust the door lock and/or exchange the gasket. (See below)
The door lock misses. Do the following test: Firmly pull the door and activate the
“door open” key. When the lock misses, than it is broken.
Replace the door lock and adjust it properly.
Loose wiring or a defect printed circuit board.
-->Check the wiring and/or exchange the printed circuit board.
• The door does not close.
The adjustment of the door is too hard. The gasket pushes too firm.
Adjust the door.
The doorlock is defect.
Replace the doorlock and adjust properly.
The manual opening feature is adjusted too taut.
-->Proper adjust the manual opening feature.
• The door opens automatically (during baking).
The manual opening feature is adjusted too taut.
-->Proper adjust the manual opening feature.
TROUBLE SHOOTING DOOR AND LOCK.