MCC
–
Cold / Ambient
EU
24/40
5.4
Cleaning Glass Panes
Cleaning the top glass pane
•
For all MCC variants, lift and hold
the top glass while cleaning the top
glass pane.
Cleaning the top air guide
WARNING
Do not use detergents and other cleaning products that may damage polycarbonate.
Using inappropriate products to clean may tarnish, scratch or even crack any
polycarbonate surfaces.
For all the MCC Models, the transparent air guide pane can be removed for cleaning.
•
Lift and hold up the top glass pane
throughout the process.
•
The air guide pane is laid up freely
and somewhat flexible and can as
such easily be removed from its
support on the rear by applying a
light amount of torsion.
•
After cleaning, place the air guide
pane back by applying some light
torsion.
•
Close the top glass pane.
For the MCC Cold SS model only: It is imperative to maintain both hygiene and transparency on
the in and outside of the top air box.
•
Lift and hold up the top glass pane
throughout the process.
•
Remove the air box cover by
sliding it out and clean it.
•
Clean each of the air box’s
compartments.
•
Slide the air box cover back in
place.
•
Close the top glass pane.