![Fri-Jado 120-2-C FS User Manual Download Page 21](http://html1.mh-extra.com/html/fri-jado/120-2-c-fs/120-2-c-fs_user-manual_2331958021.webp)
MCC
–
Cold / Ambient
EU
21/40
Loading the unit
•
Only load products of which the temperature is maximum 4ºC.
•
The maximum loading height is 50 mm below the bottom of the shelf/air guide above.
•
The maximum carrying-capacity per shelf is 30 kg/m, by equal load.
Load the cold unit only with pre-cooled products.
The unit will only maintain the product temperature.
Checking the product temperature
•
Once every hour, the product temperature should be checked using a digital thermometer.
Write down the measured values in a log.
•
Always use a disinfected thermometer sensor.
Switching off
•
Remove all products from the unit. In order to avoid temperature rise of the products, store
them in another cooling unit.
•
Switch the cooling and lighting off using the corresponding switches.
4.1.2.1 Danfoss Temperature Controller
1
Display
2
Up (
) and Down (
) keys
3
Escape/Back key
4
Enter key
Checking the temperature
•
During operation the display of the thermostat shows the temperature in the unit. The
maximum reading must not exceed 5ºC with the factory settings.
•
The indication
will light when the cooling is active.
Adjusting the SET Temperature
1. Press and release
SET
to view the current setpoint.
2. Change the setpoint value using
and
within 15 seconds.
3. To confirm the value press
SET
, or let a timeout occur (15 seconds).
For more information please refer to the Danfoss user guide for the specific controller model.
1
2
1
3
4