OPERATION AND USE
The display and/or set value is not the product/unit temperature.
Cold units are factory programmed to maintain
a product temperature ≤ 5
º
C.
The temperature can be changed from -1
º
C to +5
º
C.
4.1
Control Panel Cold Units
4.1.1 Control Panel - Self-contained units
Temperature controller
1
Display
2
Up (
) and Down (
) keys
3
Escape/Stand-by key (power on)*
4
Enter key
* Switch on/off: hold for approx. 3 sec.
Switching-on the unit
•
Switch the cooling on by means of the temperature controller.
•
Let the unit cool for approx. 30 minutes.
Loading the unit
•
Only load products of which the temperature is maximum 4ºC.
•
The maximum loading height is 50 mm below the bottom of the shelf/air guide above.
•
The maximum carrying-capacity per shelf is 30 kg/m, by equal load.
Load the cold unit only with pre-cooled products.
The unit will only maintain the product temperature.
Checking the temperature
•
During operation the display of the thermostat shows the temperature in the unit. The
maximum reading must not exceed 5ºC.
•
The indication
will light when the cooling is active.