MCC
–
Cold / Ambient
EU
12/40
3.1.1 Unpacking the front doors (optional)
The front door(s) (1-3) and fixings are placed in a crate during transport.
3.2
Installation and positioning
WARNING
Self-contained Cold units:
Propane refrigerant is highly flammable
. All safety
precautions must be followed.
WARNING
Electric chock
hazard
. Grounding instructions: only connect the appliance to an
alternating current provided by a grounded wall socket, with a mains voltage in
accordance with the information indicated on the data plate of the appliance.
It is the consumer's responsibility to make sure the electrical installation conforms
with current national and local codes and wiring regulations.
Do not use a multi plug or extension cord. Such can result in fire, electrical shock, or
other personal injury.
Failure to follow these instructions can result in death or serious injury.
WARNING
Position the unit on a flat and horizontal surface. A temporally inclined plane of
maximum 5º is allowed.
•
Place the unit level on a sufficiently sturdy floor. Keep the weight of the unit in mind. Use a
levelling instrument to level the unit
by adjusting the unit’s legs.
•
Be sure that the personnel have sufficient room to work with the unit.
•
Keep a distance of at least 150 mm between the back wall and the unit.
•
While positioning, keep the unit out of children’s reach.
•
The unit has a mains plug, and must be connected to a wall socket with the proper mains
voltage. The wall socket must be mounted by a certified electrician.
Cold Units:
•
Do not position a unit near a doorway, a ventilation device or a refrigerator in order to avoid
any negative effects on the unit’s operation by a cold airflow. The unit is designed for a
maximum draft of 0,2 m/s.
•
Do not place into direct sunlight.
•
Be sure that the ambient temperature remains between 15ºC
– 25ºC and that the relative air
humidity remains below 60%. The units have been designed to operate at climate class 3
according to ISO 23953.
•
Keep the plinth free from any obstacles to ensure ventilation.
•
Remote units: The system must be installed by qualified persons only. Refer to section 1.4.3.
•
Remote units: Fixate the unit to the floor.