Fresco Pro FFC1A-03H Manual Download Page 16

Wiring Diagram 

FCAC-KTSM-2008-12 

14 

Four-way Cassette Type 

FFC4A-06HA

Ƚ

Ƚ

FFC4A-07HA

Ƚ

FFC4A-08HA

Ƚ

FFC4A-09HA

Ƚ

FFC4A-1200HA

Ƚ

FFC4A-1500HA 

 

 
 

Summary of Contents for Pro FFC1A-03H

Page 1: ...FCAC KTSM 2008 12 Content Content i...

Page 2: ...Introduction 1 Part 1 General Information 2 Part 2 Indoor Units 5 Part 3 Installation 56 Part 4 Control 75...

Page 3: ...dvanced technology and utilize qualified galvanized iron as material Due to its supper thin design it has such advantages beautiful outlook space saving easy installation etc And the most obvious adva...

Page 4: ...General Information FCAC KTSM 2008 12 2 General Information Part 1 General Information 1 Model Names of Fan Coil 3 2 External Appearance 3 3 Nomenclature 4 4 Features 4...

Page 5: ...B 400R 3 FFC4B 045H 4 FFC4B 05H 5 With FFC4B 03H 6 FFC4B 04H 7 Four way Cassette Type Without FFC4A 06H 8 FFC4A 07H 9 FFC4A 08H 10 FFC4A 09H 11 FFC4A 1200H 12 With FFC4A 06HA 13 FFC4A 07HA 14 FFC4A 08...

Page 6: ...Hot water 2 pipes Low height for easy installation Low noise fan direct driven by single phase 3 speed permanent split capacitor motor Copper tube aluminum fin coils Hydrophilic aluminum fin coils co...

Page 7: ...FCAC KTSM 2008 12 Indoor Units Indoor Units 5 Part 2 Indoor Units Four way Cassette Type 6 Compact Four way Cassette Type 27 One way Cassette Type 40...

Page 8: ...KTSM 2008 12 6 Four way Cassette Type Four way Cassette Type 1 Features 7 2 Specification 9 3 Dimensions 11 4 Service Spaces 12 5 Wiring Diagram 13 6 Capacity Tables 15 7 Sound Levels 21 8 Exploded V...

Page 9: ...00 750CFM 230mm 850 1500CFM 300mm 2 Different color panels for choose White Gray Blue Black 3 Adding digital tube displaying on the display board LED can display the Error Code to make the malfunction...

Page 10: ...and outlet are in the same line making the installation easier 8 Electrical heater is optional 9 A full series of controller give you the most suitable solution according to the different requirement...

Page 11: ...165 143 116 100 Capacitor uF 3uF 450V 3 5uF 450V 2 5uF 450V Auxiliary Electrical Heater kW 2 1 2 1 2 7 Indoor Unit Dimension W H D mm 840 230 840 840 300 840 Packing W H D mm 955 247 955 955 317 955 N...

Page 12: ...Capacitor uF 3uF 450V 3 5uF 450V 3 5uF 450V Auxiliary Electrical Heater kW 2 7 Indoor Unit Dimension W H D mm 840 300 840 Packing W H D mm 955 317 955 Net Gross Weight kg 35 42 Panel Dimension W H D...

Page 13: ...FCAC KTSM 2008 12 Dimensions Four way Cassette Type 11 3 Dimensions Model A B C 600CFM 750CFM 230 170 260 850CFM 950CFM 1200CFM 1500CFM 300 190 330...

Page 14: ...Service Spaces FCAC KTSM 2008 12 12 Four way Cassette Type 4 Service Spaces Model A B C 600CFM 750CFM 230 170 260 850CFM 950CFM 1200CFM 1500CFM 300 190 330...

Page 15: ...FCAC KTSM 2008 12 Wiring Diagram Four way Cassette Type 13 5 Wiring Diagram FFC4A 06H FFC4A 07H FFC4A 08H FFC4A 09H FFC4A 1200H FFC4A 1500H...

Page 16: ...Wiring Diagram FCAC KTSM 2008 12 14 Four way Cassette Type FFC4A 06HA FFC4A 07HA FFC4A 08HA FFC4A 09HA FFC4A 1200HA FFC4A 1500HA...

Page 17: ...19 88 29 110 1 5 5 14 5 9 670 772 16 9 16 2 42 2 16 0 38 9 94 29 110 1 29 21 7 12 5 670 772 14 2 13 3 5 91 4 34 1 02 26 68 29 110 1 5 5 14 5 9 670 772 18 17 1 3 25 2 39 0 51 13 34 29 110 1 Low 26 7 1...

Page 18: ...3 72 3 39 0 58 13 50 35 165 1 29 21 7 12 5 840 1445 15 14 9 13 6 81 1 57 36 54 35 165 1 5 5 14 5 9 840 1445 18 4 17 4 5 02 3 75 0 79 18 27 35 165 1 Mid 26 7 19 4 7 12 5 770 1218 14 2 13 2 6 35 5 20 1...

Page 19: ...7 5 99 1 40 31 82 35 116 1 5 5 14 5 9 640 1153 17 6 16 7 4 49 3 29 0 70 15 91 35 116 1 FFC4A 1200H High 26 7 19 4 7 12 5 840 2040 14 6 13 9 10 18 8 75 1 75 46 67 35 165 1 5 5 14 5 9 840 2040 17 6 16 6...

Page 20: ...94 43 53 35 143 1 5 5 14 5 9 770 2150 17 16 2 6 20 5 36 0 97 21 77 35 143 1 27 19 7 12 5 770 2150 14 13 1 11 51 9 98 1 98 41 06 35 143 1 5 5 14 5 9 770 2150 16 9 16 5 87 5 59 0 92 20 53 35 143 1 29 21...

Page 21: ......

Page 22: ...8 27 01 12 95 1 59 31 12 14 68 1 80 35 23 6 2 90 0 42 8 22 4 64 0 66 12 92 6 36 0 91 17 81 8 09 1 16 22 70 9 82 1 41 27 59 11 55 1 65 32 29 13 28 1 90 37 18 15 01 2 15 42 08 5 3 23 0 55 10 76 4 96 0 8...

Page 23: ...12 Sound Levels Four way Cassette Type 21 7 Sound Levels TYPE FFC4A 600 R A FFC4A 750 R A FFC4A 850 R A FFC4A 950 R A FFC4A 1200 R A FFC4A 1500 R A Noise dB A 45 46 47 48 49 49 FOUR WAY CASSETTE TYPE...

Page 24: ...Exploded View FCAC KTSM 2008 12 22 Four way Cassette Type 8 Exploded View FFC4A 06H FFC4A 07H FFC4A 08H FFC4A 09H FFC4A 1200H FFC4A 1500H...

Page 25: ...y 1 24 Fan fixer 1 5 Foam subassembly drain tray 1 25 Water finder cover subassembly 1 6 Fan assembly 1 26 Front barrier III subassembly 1 7 Evaporator fixing board 1 26 1 Install lifting lug 4 8 Evap...

Page 26: ...Exploded View FCAC KTSM 2008 12 24 Four way Cassette Type FFC4A 06HA FFC4A 07HA FFC4A 08HA FFC4A 09HA FFC4A 1200HA FFC4A 1500HA...

Page 27: ...inducting coils subassembly 1 25 Fan fixer 1 5 Foam subassembly drain tray 1 26 Water finder cover subassembly 1 6 Fan assembly 1 27 Front barrier III subassembly 1 7 Evaporator fixing board 1 27 1 I...

Page 28: ...g No Malfunction Operation lamp Timer lamp Defrosting lamp Alarm lamp Error code 1 Room temp sensor checking channel is abnormal X X X E2 2 Evaporator pipe temp sensor checking channel is abnormal X X...

Page 29: ...tte Type Compact Four way Cassette Type 27 Compact Four way Cassette Type 1 Features 28 2 Specification 29 3 Dimensions 30 4 Service Space 31 5 Wiring Diagram 32 6 Capacity Tables 33 7 Sound Levels 37...

Page 30: ...intenance only available for small four way cassette Little space is required for installation into a shallow ceiling Because of the compactness and weight reduction of the main unit and panel all mod...

Page 31: ...put W 65 59 55 50 89 83 77 71 89 83 77 71 Capacitor uF 1uF 450V 1 5uF 450V 2uF 450V 2 5uF 450V Indoor unit Dimension W H D mm 580 254 580 Packing W H D mm 750 340 745 Net Gross weight kg 23 29 23 29 P...

Page 32: ...Dimensions FCAC KTSM 2008 12 30 Compact Four way Cassette Type 3 Dimensions FFC4B 03H FFC4B 04H FFC4B 045H FFC4B 05H...

Page 33: ...FCAC KTSM 2008 12 Service Space Compact Four way Cassette Type 31 4 Service Space...

Page 34: ...Wiring Diagram FCAC KTSM 2008 12 32 Compact Four way Cassette Type 5 Wiring Diagram FFC4B 03H FFC4B 04H FFC4B 045H FFC4B 05H...

Page 35: ...6 0 76 0 17 7 10 23 55 1 27 19 7 12 5 770 300 13 8 12 9 1 84 1 45 0 32 11 50 23 55 1 5 5 14 5 9 770 300 16 7 15 7 1 01 0 80 0 16 7 00 23 55 1 29 21 7 12 5 770 300 13 5 12 6 2 41 1 58 0 41 17 00 23 55...

Page 36: ...6 77 1 5 5 14 5 9 930 597 17 6 16 7 2 74 1 82 0 43 10 50 26 77 1 FFC4B 05H High 26 7 19 4 7 12 5 1070 850 14 6 13 9 5 39 3 95 0 93 29 10 26 89 1 5 5 14 5 9 1070 850 17 6 16 6 2 96 2 17 0 47 11 00 26 8...

Page 37: ......

Page 38: ...0 41 9 14 4 27 0 52 11 60 5 16 0 63 14 05 6 06 0 74 16 50 6 95 0 85 18 96 7 85 0 96 21 41 6 1 70 0 24 5 35 2 61 0 37 8 25 3 51 0 50 11 15 4 40 0 63 14 05 5 30 0 76 16 95 6 19 0 89 19 85 7 08 1 01 22 5...

Page 39: ...FCAC KTSM 2008 12 Sound Levels Compact Four way Cassette Type 37 7 Sound Levels Model FFC4B 03H FFC4B 04H FFC4B 045H FFC4B 05H Noise dB A 39 41 42 43 FOUR WAY CASSETTE TYPE Microphone P...

Page 40: ...er 1 17 1 E Part box 1 4 Evaporator fixing board ass y 1 17 2 Motor capacitor 1 5 Connecting pipe 1 17 3 Transformer 1 6 Drain pump 1 17 4 Main controller ass y 1 7 Remote controller 1 17 5 Control bo...

Page 41: ...6 7 hole terminal 1 7 Remote controller 1 16 7 Terminal 1 8 Water level sensor 1 17 Protection net of fan wheel 1 9 Tube temperature sensor 1 18 Motor 1 10 Right plate 1 19 Centrifugal fan wheel 1 11...

Page 42: ...KTSM 2008 12 40 One way Cassette Type One way Cassette Type 1 Feature 41 2 Specification 42 3 Dimensions 43 4 Service Space 44 5 Wiring Diagrams 45 6 Capacity Tables 47 7 Sound Levels 51 8 Explored Vi...

Page 43: ...harmonious with any interior decoration and creates an elegant environment 4 Ultra thin body Space saving 5 Convenient installation Able to be flexibly installed in various corners Standardized sectio...

Page 44: ...Fan motor Type Low Noise 4 speed AC motor Quantity 1 1 1 Indoor unit Net dimension W H D mm 1054x169x425 1200x198x655 Packing W H D mm 1155x245x490 1380x265x720 Net Gross weight kg 12 8 16 6 32 6 36...

Page 45: ...FCAC KTSM 2008 12 Dimensions One way Cassette Type 43 3 Dimensions FFC1A 03H FFC1A 04H FFC1A 06H...

Page 46: ...Service Space FCAC KTSM 2008 12 44 One way Cassette Type 4 Service Space FFC1A 03H FFC1A 04H...

Page 47: ...FCAC KTSM 2008 12 Wiring Diagrams One way Cassette Type 45 5 Wiring Diagrams FFC1A 03H FFC1A 03HA...

Page 48: ...Wiring Diagrams FCAC KTSM 2008 12 46 One way Cassette Type FFC1A 04H FFC1A 04HA...

Page 49: ...0 24 3 80 23 42 1 29 21 7 12 5 900 459 14 2 13 3 3 37 2 22 0 58 13 20 23 42 1 5 5 14 5 9 900 459 18 17 1 1 85 1 22 0 29 5 80 23 42 1 Low 26 7 19 4 7 12 5 820 408 13 6 12 7 2 52 1 78 0 43 10 90 23 40...

Page 50: ...60 31 82 1 29 21 7 12 5 1180 1020 15 14 6 27 4 62 1 08 25 34 31 82 1 5 5 14 5 9 1180 1020 18 4 17 4 3 45 2 54 0 54 11 40 31 82 1 Mid 26 7 19 4 7 12 5 1120 978 14 2 13 2 4 82 3 92 0 83 20 63 31 80 1 5...

Page 51: ......

Page 52: ...96 17 00 6 38 1 10 19 48 7 16 1 23 21 78 FFC1A 04H 680 10 1 13 0 10 2 04 2 24 0 19 3 88 3 29 0 28 5 72 4 32 0 37 7 56 5 34 0 46 9 39 6 36 0 55 11 23 7 37 0 63 12 86 8 37 0 72 14 70 8 1 53 0 16 3 27 2...

Page 53: ...FCAC KTSM 2008 12 Sound Levels One way Cassette Type 51 7 Sound Levels TYPE FFC1A 03H FFC1A 04H Noise dB A 38 40 ONE WAY CASSETTE TYPE Microphone P...

Page 54: ...Explored View FCAC KTSM 2008 12 52 One way Cassette Type 8 Explored View FFC1A 03H FFC1A 04H...

Page 55: ...cover of evaporator 1 4 3 Evaporator 1 18 Supporter of water level switch 1 5 Air leading foam 1 18 1 Water level sensor 1 6 Heat insulation of drain pipe 1 19 cover 1 7 Water leading plate 1 20 Supp...

Page 56: ...Explored View FCAC KTSM 2008 12 54 One way Cassette Type FFC1A 03HA FFC1A 04HA...

Page 57: ...nsulation of drain pipe 1 19 Cover 1 7 Water leading plate 1 20 Supporter of motor 1 8 Small cover 1 21 Lower volute 2 9 Drain pump 1 22 Upper volute 2 10 Middle cover 1 23 Air louver 1 11 Fan motor 1...

Page 58: ...Installation FCAC KTSM 2008 12 56 Installation Part 3 Installation The Installation of FFC1A 57 The Installation of FFC4A FFC4B 65...

Page 59: ...TSM 2008 12 The Installation of FFC1A The Installation of FFC1A 57 The Installation of FFC1A 1 Installation Attention 58 2 Install the Main Body 59 3 Install the Panel 61 4 Install Drain Pipe 62 5 Wri...

Page 60: ...air is the least The air flow can reach throughout the room The connecting pipe and drainpipe could be extracted out easily There is no direct radiation from heaters Service space FFC1A 03H FFC1A 04H...

Page 61: ...ion 1 The size of the ceiling to be handled Do keep the ceiling flat Consolidate the roof beam for possible vibration 2 Cut off the roof beam 3 Strengthen the place that has been cut off and consolida...

Page 62: ...Install the Main Body FCAC KTSM 2008 12 60 The Installation of FFC1A z Install the hanging bolt into U groove of the hanging tool Overhang the indoor unit and ensure it is level using a level gauge...

Page 63: ...The panel and the ceiling the panel and the unit body should be connected closely or air leakage water leakage and condensate dew will be caused z Please refer to the panel installation manual to inst...

Page 64: ...xceed 20m When the pipe is over long a bracket must be installed to prevent winding z Refer to the following figures to install the pipes Note 1 Injury means causing from the harm burn and electrical...

Page 65: ...the power and operate the air conditioner under the COOLING mode The drainage test is doing during checking the drain pump motor running sound 3 Turn off the power drain the water away Pipe connection...

Page 66: ...nce and their contact with connecting pipe or stop valve body 5 The wiring 5 core shield cable attached between the signal receiving board and the wire controller is not more than 2m Be sure to prolon...

Page 67: ...ation of FFC4A FFC4B 65 The Installation of FFC4A FFC4B 1 Before Installation 66 2 Installation space 66 3 Installation procedures for fresh air intake duct connection 66 4 Install the Main Body 67 5...

Page 68: ...There is no direct radiation from heaters Caution Keep indoor unit outdoor unit power supply wiring and transmission wiring at least 1 meter away from televisions and radios This is to prevent image...

Page 69: ...e the balance of the body z If the drainpipe is awry leakage will be caused by the malfunction of the water level switch z Adjust the position to ensure the gaps between the body and the four sides of...

Page 70: ...Install the Main Body FCAC KTSM 2008 12 68 The Installation of FFC4A FFC4B...

Page 71: ...FCAC KTSM 2008 12 Install the Main Body The Installation of FFC4A FFC4B 69...

Page 72: ...n of the arrow in Chart12 slightly to fit the panel s center to the center of the ceiling s opening Guarantee that hooks of four corners are fixed well e Keep fastening the screws under the panel hook...

Page 73: ...FCAC KTSM 2008 12 Install the Panel The Installation of FFC4A FFC4B 71...

Page 74: ...pe with the connecting pipe to fix it Refer to Chart c In the case of prolonged drainpipe you had better tighten its indoor part with a protection tube to prevent it from loosing If the outlet of the...

Page 75: ...Cautions If there is any malfunction please resolve it immediately 3 Stop the air conditioner for there minutes check if everything is ok If the drain hose is located unreasonable water overflow will...

Page 76: ...e done at the main power distribution The distribution has to be of a low impedance normally the required impedance reaches at a 32 A fusing point 2 No other equipment has to be connected with this po...

Page 77: ...FCAC KTSM 2008 12 Control Control 75 Part 4 Control Wireless remote controller R51 E 76 Wireless remote controller R05 BGE 78...

Page 78: ...ting Signal 2 0V Reaching Distance 8m when using 3 0 voltage it can get 11m Environment Temperature Range 5 60 Introduction of Function Buttons on the Remote Controller 1 TEMP DOWN Button Push the TEM...

Page 79: ...tton Push this button to cancel the TIMER settings 8 TIMER Button This button is used to preset the time ON start to operate and the time OFF turn off the operation 9 ON OFF Button Push this button to...

Page 80: ...ditioners Precautions Curtain door or the similar objects will prevent the remote signal from being received by air conditioner Do not get the interior of remote controller wet It is forbidden to expo...

Page 81: ...wing Activate or turn off wind horizontal swing function Only available when remote controller is used with corresponding unit 8 Wind Vert Swing Activate or turn off wind vertical swing function Only...

Page 82: ...This icon will be lightened or off when pressing ECO button NOTE All the above icons will be displayed only when the remote controller is electrified for the first time or reset OPERATION INSTRUCTION...

Page 83: ...e by 1 hour 4 0 5s after setting remote controller will send TIME OFF command to the unit Set TIME ON and TIME OFF simultaneously 1 Set TIME ON according to procedures 1 and 2 specified in TIME ON ope...