background image

© Fresair, LLC. 

Fresair.com

10 of 21

Warranty Information

The warranty period begins on the purchase date and ends 12 months from the purchase

date with exceptions to certain replacement parts as outlined in the manual. 

If the product is defective, please contact the dealer you purchased from or contact Fresair

directly by emailing [email protected]. For repair and warranty processing, please

include a copy of the receipt with purchase date and a reason for the claim and/or

description of the fault.

In no case will Fresair exchange the product for a replacement solely due to a defective

component. 

NOTICE!

If kept in off mode for an extended period of time, there may be an odor when

turning it on again as a result of the absence of water cycling through the

straw filter. You may remedy this by running a few cycles and the odor will

naturally subside.

NOTICE!

This model has exclusive application for on road uses. We do not recommend

extreme off road uses at this time.

A. Damages caused by accidents; 

B. Plastic items: superior cover in ABS plastic, main panel, finishing frame and base; 

C. Electric harness or hoses cut or damaged; 

D. Control panel with any sign of modification or use with other brand; 

E. Fan with broken or damaged airscrew or with normal brush wear and tear; 

F. Air filter obstructed by dirt or dust; 

G. Any component in which the label with the date of manufacture is removed or not

legible; 

H. Use of unauthorized parts, unauthorized modifications, or unauthorized repairs made by

technicians or individuals who are not licensed or not qualified to modify or repair Fresair

units; 

I. Off road application; 

J. Unsatisfactory product performance due to improper installation; 

K. Damage caused by unexpected circumstances (ex: accident, fall, wear and tear, violent

weather conditions, use of chemical abrasive products inside and outside the product,

etc.); 

L. If the product is switched on at a different voltage than it was intended for; 

M. Removal of and/or modification of the serial number or the product identification label. 

NOTICE!

Never add anti-freeze, softener, perfume, fragrance or any other substance

than pure water in the reservoir. Adding substances could create foam or

potentially cause leaks. 

Summary of Contents for S7i

Page 1: ...S7i MANUAL Fresair LLC All Rights Reserved...

Page 2: ...you re about to enjoy the fruits of an innovative high quality product designed exclusively to provide you with extreme comfort in hot climates We take pride in our products and want you to feel confi...

Page 3: ...er levels 5 fan speeds Fan Speed Low Water Interior Light Press button to turn water circulation on and off When the water tank level is low the LOW WATER LED starts blinking The light will remain sol...

Page 4: ...not make any alterations or structural changes to the device Do not use the Fresair Air Cooling Unit if it is visibly damaged Installation and repairs to the Fresair Air Cooling Unit may only be carr...

Page 5: ...the water reservoir The pine straw filter is never oversaturated and water usage is conserved by this regular flow of water between the reservoir and the unit The resultant air flowing into the vehicl...

Page 6: ...er Consumption 100 to 1000 ml h depending on the external moisture and temperature Capacity 12L water tank Fan Double fan with ohmic resistance Voltage 12V Maximum Nominal Current 12V 10A Fan Speed 40...

Page 7: ...gregated data Fresair is not responsible for exact achievable temperatures or comfort zones as installations differ Comfort Cool with air flow ceiling fan or window Use directional air from vents on t...

Page 8: ...tive care maintenance or general questions please contact an authorized dealer or reach out to us directly at support fresair com Additionally we have outlined some of our go to resources for question...

Page 9: ...the any or all of the 4 directional vents to point the airflow to the desired areas Ensure water reservoir is full The water pump automatically turns on when the unit is turned on provided there is wa...

Page 10: ...nts B Plastic items superior cover in ABS plastic main panel finishing frame and base C Electric harness or hoses cut or damaged D Control panel with any sign of modification or use with other brand E...

Page 11: ...ible for a second filtering process avoiding the entry of dirt into the pump protecting the pump from clogging and breaking down Tray Pre Filter INJECTION The injection pump is located on the outside...

Page 12: ...l and the low water warning light remains on check that the sensor is inserted correctly in the reservoir with the green dot facing up If the sensor is inserted correctly and the light remains on it s...

Page 13: ...resair Owner s Manual 2 Fresair Decals 1 Remote Control Fresair Unit Self Sticking Sealing Foam Inner Edge Use Self Sticking Sealing Foam Outer Edge Use Cardboard Mounting Template Fresair LLC Fresair...

Page 14: ...oard Mounting Template Masking Tape Permanent Marker Place the Cardboard Mounting Template over the exact roof area where you plan to mount your Fresair Unit Ensure the larger notch side A is position...

Page 15: ...as safety glasses gloves long sleeves etc Cut the opening of 14 5 wide side to side of roof by 13 tall front to back of roof along the outline as closely as possible File any newly cut edges and ensu...

Page 16: ...t length ensuring there are no gaps where the sealing foam tape ends meet Apply a single bead of silicone along the middle of both the foam on the unit and the foam on the roof Carefully lower the uni...

Page 17: ...es Self leveling lap sealant Silicone Inspect how well the foam has compressed over roof ridge lines If there are any gaps you need to run self leveling lap sealant around the outside of the base and...

Page 18: ...ted for safety purposes Run the electrical wiring from the unit to the 12V DC fuse block ensuring it is completely concealed so that the wire is not exposed to elements or incidental damage Connect th...

Page 19: ...water emerge from the out hose on the water fill connector the reservoir is full Finally power on your Fresair and ensure there are no leaks Additionally test all functions to ensure your Fresair is...

Page 20: ...and tighten when necessary Be careful not to over tighten as you could warp or crack the base Check regularly that the connection lines are undamaged and secure Check the filter every 6 months and rep...

Page 21: ...Your Local Dealer Your Local Support fresair com dealer fresair com contact Fresair LLC All Rights Reserved...