Chapter 3. Using the Monitor/Debug Firmware
3-5
Command Line Usage
3.3
Command Line Usage
The user interface to dBUG is the command line. A number of features have been
implemented to achieve an easy and intuitive command line interface.
dBUG assumes that an 80x24 ASCII character dumb terminal is used to connect to the
debugger. For serial communications, dBUG requires eight data bits, no parity, and one stop
bit (8-N-1) with no flow control. The baud rate default is 19200 bps—a speed commonly
available from workstations, personal computers and dedicated terminals.
The command line prompt is: dBUG>
Any dBUG command may be entered from this prompt. dBUG does not allow command
lines to exceed 80 characters. Wherever possible, dBUG displays data in 80 columns or
less. dBUG echoes each character as it is typed, eliminating the need for any local echo on
the terminal side.
The <Backspace> and <Delete> keys are recognized as rub-out keys for correcting
typographical mistakes.
Command lines may be recalled using the <Control> U, <Control> D and <Control> R key
sequences. <Control> U and <Control> D cycle up and down through previous command
lines. <Control> R recalls and executes the last command line.
In general, dBUG is not case-sensitive. Commands may be entered either in uppercase or
lowercase, depending upon the user’s equipment and preference. Only symbol names
require that the exact case be used.
Most commands can be recognized by using an abbreviated name. For instance, entering h
is the same as entering help. Thus it is not necessary to type the entire command name.
The commands DI, GO, MD, STEP and TRACE are used repeatedly when debugging.
dBUG recognizes this and allows for repeated execution of these commands with minimal
typing. After a command is entered, press the <Return> or <Enter> key to invoke the
command again. The command is executed as if no command line parameters were
provided.
3.4
Commands
This section lists the commands that are available with all versions of dBUG. Some board
or CPU combinations may use additional commands not listed below.
Summary of Contents for ColdFire MCF5274
Page 8: ...4 M5275EVB User s Manual Freescale CONTENTS Paragraph Number Title Page Number...
Page 37: ...Chapter 2 Initialization and Setup 2 7 Installation and Setup Figure 2 5 Jumper Locations...
Page 84: ...Troubleshooting Network Problems A 4 M5275EVB User s Manual...
Page 85: ...Appendix B Schematics B 1 Appendix B Schematics B 1 M5275EVB Schematics...
Page 86: ...M5275EVB Schematics B 2 M5275EVB User s Manual...
Page 87: ...MOTOROLA Appendix B Schematics B 3 M5275EVB Schematics...
Page 88: ...M5275EVB Schematics B 4 M5275EVB User s Manual...
Page 89: ...MOTOROLA Appendix B Schematics B 5 M5275EVB Schematics...
Page 90: ...M5275EVB Schematics B 6 M5275EVB User s Manual...
Page 91: ...MOTOROLA Appendix B Schematics B 7 M5275EVB Schematics...
Page 92: ...M5275EVB Schematics B 8 M5275EVB User s Manual...
Page 93: ...MOTOROLA Appendix B Schematics B 9 M5275EVB Schematics...
Page 94: ...M5275EVB Schematics B 10 M5275EVB User s Manual...
Page 95: ...MOTOROLA Appendix B Schematics B 11 M5275EVB Schematics...
Page 96: ...M5275EVB Schematics B 12 M5275EVB User s Manual...
Page 97: ...MOTOROLA Appendix B Schematics B 13 M5275EVB Schematics...
Page 98: ...M5275EVB Schematics B 14 M5275EVB User s Manual...
Page 99: ...MOTOROLA Appendix B Schematics B 15 M5275EVB Schematics...
Page 100: ...M5275EVB Schematics B 16 M5275EVB User s Manual...
Page 101: ...Appendix C M5275EVB BOM C 1 Appendix C M5275EVB BOM C 1 M5275EVB BOM...