Freeman PST9032Q Manual Download Page 6

11

10

MAINTENANCE

Any  time  inspection,  maintenance,  and 

cleaning are done:

Disconnect the tool from the air source.
Empty the magazine completely.

WARNING:

!

It is advisable to test the depth on a scrap

workpiece  to  determine  the  required 
depth for the application.
To determine depth of drive, first adjust 

the air pressure and drive a test fastener. 
Never exceed 120psi.

CAUTION:

Each  tool is packed with an anti-dust cap on the air 
connector, 

   

 

Keep  the  anti-dust  cap  cover  the  air  connector 
when the tool is not in use.

check it after unpacking.

ANTI DUST CAP

-

Always know the operational mode of the 

tool  before  using.  Failure  to  know  the 
operational mode could result in death or 
serious personal injury.

WARNING:

!

FIRING THE TOOL 

The tool is specially designed for single sequential 
mode. This mode requires the trigger to be pulled 
each  time  a  fastener  is  driven.  The  tool  can  be 
actuated by depressing the WCE against the work 
surface followed pulling the trigger.
The trigger must be released to reset the tool before 
another fastener can be driven.

An  improperly  functioning  tool  must  not 

be used. Do not actuate the tool unless the 
tool  is  placed  firmly  against  the  work 
place.

WARNING:

!

WORK CONTACT ELEMENT (WCE) 

Disconnect the air supply from the tool.
Remove all fasteners from the magazine.
Make sure the trigger and work contact element 
move  freely  up  and  down  without  sticking  or 
binding.
Reconnect air supply to the tool.
Depress  the  work  contact  element  against  the 
work surface without pulling the trigger. The tool 
must  not  operate.  Do  not  use  the  tool  if  it 
operates  without  pulling  the  trigger.  Personal 
injury may result.
Remove  the  tool  from  the  work  surface.  The 
work contact element (WCE) must return to its 
original  down  position.  The  tool  must  not 
operate. Do not use the tool if it operates while 
lifted from the work surface. Personal injury may 
result.
Pull  the  trigger  and  depress  the  work  contact 
element(WCE)  against  the  work  surface.  The 
tool must not operate.
Depress  the  work  contact  element(WCE) 
against  the  surface.  Pull  the  trigger.  The  tool 
must operate. 


Check the operation of the work contact 

element trip mechanism before each use. 

The  WCE  must  move  freely  without 

binding through its entire travel distance. 

The WCE spring must return the WCE to 

its  fully  extended  position  after  being 

depressed. Do not operate the tool if the 

WCE  trip  mechanism  is  not  operating 

properly. Personal injury may occur.

CAUTION:

The  tool  is  uniquely  designed  not  to  need  daily 

lubrication.  But  lubrication  is  required  for  best 
performance  after  long  periods  of  use.  Oil  for 
pneumatic fastening tools is added through the air 

line connection and will lubricate internal parts. Do 
not use detergent oil or additives. These lubricants 
will  cause  accelerated  wear  to  the  seals  and 

bumpers  in  the  tool,  resulting  in  poor  tool 
performance  and  frequent  tool  maintenance.

LUBRICATION

Do  not  at  any  time  let  brake  fluids, 

gasoline,  petroleum-based  products, 

penetration  oils,  ect.,  come  in  contact 

with plastic parts. Chemicals can damage, 

weaken  or  destroy  plastic  which  may 

result in serious personal injury.

WARNING:

!

Do  not  store  tools  in  a  cold  weather 

environment  to  prevent  frost  or  ice 
formation on the tool's operating valves 
and  mechanisms  that  could  cause  tool 

failure.

CAUTION:

COLD WEATHER OPERATION

For cold weather operation, near and below freezing, 

the moisture in the air line may freeze and prevent 
tool operation. We recommend  the use of air tool 
lubricant or permanent antifreeze (ethylene glycol) 

as a cold weather lubricant.

Lubricate  tool  only  with  specified 

lubricants.

CAUTION:

Avoid  using  solvents  when  cleaning  plastic  parts. 

Most  plastics  are  susceptible  to  damage  from 
various  types  of  commercial  solvents  and  maybe 
damaged by their use. Use clean cloths to remove 

dirt, dust, oil, grease, etc.

CLEANING

RECOMMENDED HOOKUP

The  air  compressor  must  be  able  to 

maintain  a  minimum  of  60psi  when  the 
tool  is  being  used.  An  inadequate  air 
supply  can  cause  a  loss  of  power  and 

inconsistent driving.

CAUTION:

Do  not  connect  with  an  air  compressor 

which  can potentially exceed  200psi. As 
tool may burst, possibly causing injury. 

WARNING:

!

The air compressor must be able to maintain a 

minimum of 60psi when the tool is being used. 
An  inadequate  air  supply  can  cause  a  loss  of 
power and inconsistent driving.

An  oiler  can  be  used  to  provide  oil  circulation 
through the tool. A filter can be used to remove 
liquid and solid impurities which can rust or gum 

up internal parts of the tool.
Always  use  air  supply  hoses  with  a  minimum 

working pressure rating equal to or greater than 
the pressure from the power source if a regulator 
fails, or 150psi, whichever is greater. Use 3/8" air 

hose for runs up to 50'. Use 1/2" air hoses for 50' 
run  or  longer.  For  better performance,  install a 
3/8" quick plug(1/4" NPT thread) with an inside 

diameter  of  0.315" (8mm) on the tool and  3/8" 
quick coupler on the air hose.

Use  a  pressure  regulator  on  the  compressor, 
with  an  operating  pressure  of  0-125psi.  A 
pressure  regulator  is  required  to  control  the 

operating pressure of the tool between 60psi and 
100psi.

3.

2.

1.

Quick 

connector

Quick 

Coupler

Air hose

Quick 

connector

Oiler

Regulator

Filter

Compressor

Quick 

Coupler

MODEL: PST9032Q

MODEL: PST9032Q

HTTP://WWW FREEMANTOOLS COM        1-888-669-5672

.

.

HTTP://WWW FREEMANTOOLS COM        1-888-669-5672

.

.

Summary of Contents for PST9032Q

Page 1: ...ARNING KEEP YOUR DATED PROOF OF PURCHASE FOR WARRANTY PURPOSES IMF300603AV 04 12 SAVE THIS MANUAL FOR FUTURE REFERENCE Failure to follow warnings could result in DEATH OR SERIOUS INJURY MODEL PST9032Q...

Page 2: ...il to be deflected and hit someone or cause the tool to react and result in a risk of injury to persons A dust mask non skid safety shoes and a hard hat must be used for the applicable conditions Wear...

Page 3: ...use this tool in a manner that could cause a fastener to be directed toward anything other than the workpiece Never use gasoline or other flammable liquids to clean the tool Do not remove tamper with...

Page 4: ...inspected and satisfactorily operated the tool If any parts are damaged or missing please call 1 888 669 5672 If any parts are missing do not operate this tool until the missing parts are replaced Fai...

Page 5: ...with consistent results It may be possible to achieve the desired depth with air pressure adjustments alone NON MARRING PAD The no marring pad attached the nose of the tool helps prevent marring and d...

Page 6: ...g periods of use Oil for pneumatic fastening tools is added through the air line connection and will lubricate internal parts Do not use detergent oil or additives These lubricants will cause accelera...

Page 7: ...rs Other than the postage and insurance requirement no charge will be made for repairs covered by this warranty These warranties do not apply to defects in materials or workmanship or damages resultin...

Page 8: ...COMPRA CON FECHAPARA FINES DELA GARAT A No seguir las advertencias correctamente puede causar LA MUERTE O LESIONES GRAVES MODEL PST9032Q MODEL PST9032Q HTTP WWW FREEMANTOOLS COM 1 888 669 5672 MODELO...

Page 9: ...as partes m viles La ropa y las joyas sueltas o el cabello largo pueden quedar atrapados en las partes m viles n el gatillo ya que la herramienta puede disparar un sujetador SEGURIDAD PERSONAL Evite l...

Page 10: ...nt n la herramienta y el mango secos limpios y libres de aceite o grasa No utilices la herramienta como martillo No utilices esta herramienta de tal manera que los fijadores se dirijan hacia cualquier...

Page 11: ...ienta no est en uso Al desplazarse a otra rea de trabajo Dichas medidas de precauci n reducir n el riesgo de lesiones a personas Respeta la herramienta como implemento de trabajo Nunca la uses en brom...

Page 12: ...CIA Bot n del pestillo B CARACTER STICAS ESCAPE AJUSTABLE EN 360 GRADOS DISE O SIN ACEITE Permite al usuario controlar el aire lejos de los cara Para un menor mantenimiento CARGADOR Y CILINDRO DE ALUM...

Page 13: ...completo ADVERTENCIA Todas las herramientas vienen con un tap n antipolvo en el conector de aire verif calo si lo tienes despu s de desempacar la herramienta Mant n el tap n antipolvo para cubrir el...

Page 14: ...dejes que l quidos para freno gasolina productos a base de petr leo aceites penetrantes etc entren en contacto con las piezas pl sticas Estos qu micos pueden da ar debilitar o destruir el pl stico lo...

Page 15: ...las garant as nicas y exclusivas expresas o impl citas para el Producto Freeman Ning n empleado agente distribuidor u otra persona tiene la autorizaci n para modificar aumentar o reducir los t rminos...

Page 16: ...AVERTISSEMENT GARDEZ VOTRE PREUVE D ACHAT DAT E DES FINS DE GARANTIE CONSERVEZ CE MANUEL POUR R F RENCE ULT RIEURE HTTP WWW FREEMANTOOLS COM 1 888 669 5672 PRIME GLOBAL PRODUCTS INC Tout manquement au...

Page 17: ...et si vous produisez de la limaille ou des copeaux de bois vitez de porter des v tements amples ou des bijoux Attachez les cheveux longs Gardez les cheveux les v tements et les gants l cart des pi ces...

Page 18: ...Maintenir l outil avec votre main ou contre votre corps est instable et risque de causer la perte de contr le de l outil Utilisez toujours un chiffon propre pour le nettoyage N utilisez pas de liquid...

Page 19: ...utilis Lors d un d placement vers une autre zone de travail afin d viter une activation accidentelle pouvant causer des blessures CHARGEMENT DE L OUTIL Ne chargez pas d attaches dans l outil lorsque l...

Page 20: ...sez des pinces ou un tournevis pour d gager l attache coinc e Fermez le m canisme de d blocage et le verrou Reconnectez l outil la source d alimentation en air Remettez les attaches dans l outil Tirez...

Page 21: ...contact doit se d placer librement sans se coincer Le ressort de l l ment de contact doit le ramener sa position allong e N utilisez pas l outil si le m canisme de d clenchement de l l ment de contact...

Page 22: ...sin 4 Remplacez le ressort 5 V rifiez le raccord le tuyau ou le compresseur 6 Remplacez et lubrifiez les joints toriques 7 Remplacez les joints toriques 8 Resserrez les vis et les raccords 9 Remplacez...

Page 23: ...u en r duire la port e ni offrir toute autre garantie au nom de PGP Inc Ces garanties limit es expresses contiennent AUCUNE GARANTIE AUTRE QUE LA GARANTIE CI DESSUS QU ELLE SOIT VERBALE OU CRITE EXPRE...

Reviews: