TCA200 Rev171031
19
Preset Settings (Pressure or RPM)
The preset button allows the operator to go to a pre-programmed pressure or
RPM setting during operations. The setting will be shown in the message display. This
procedure is to change the setting in the program.
Note:
The engine must be running and the pump engaged interlock circuit
must be closed (the THROTTLE READY LED
must be on
).
1. Press
IDLE
button.
Result: Engine goes to idle RPM
2. Press
MODE
button to select which setting to change.
Result: LED indicator goes on for mode selected.
Note:
The message display must show
IDLE
before changing the preset.
3. Press and hold
PRESET
button. (Continue to hold through step 4.)
Result: Message display flashes then shows
preset...
after 5 seconds the current
setting shows.
4. Press the
INC DEC
buttons to change preset setting.
5. Release
PRESET
button.
Result: The new preset is programmed. Message display shows
IDLE
.
High Idle
The governor programming includes a high idle function. To activate the high idle
set interlocks as called for by SOP (normally this would include the transmission in
neutral and the parking brake on ). Set the High Idle switch to ON.
Note:
The pump must NOT be engaged when using the high idle function
and the THROTTLE READY LED will be off.
Change High Idle Setting
Note:
The high idle is set at about 1000 RPM at the factory.
1. With the engine running, set the high idle switch to ON.
2. Press and hold
PRESET
button for 3 seconds.
Result: Message display will flash the high idle setting.
3. Keep pressing the
PRESET
button and press the
INC/DEC
buttons to set
desired RPM.
4. Release
PRESET
button to store the new high idle setting.