INSTALLATION AND SETUP
Installation Process
15
Typical Surface Pressure Boosting Application
The above drawing illustrates how a typical surface mounted pump system should be arranged for
a pressure boosting application.
1.
Water Supply
2.
Check Valve
3.
Ball Valve
4.
Pressure Relief Valve:
Pressure relief valve must be able to pass full pump flow at 100 PSI.
5.
Pressure Tank
. Refer to
“Minimum Pressure Tank and Supply Pipe Sizing” on page
6.
Pressure Gauge
7.
Pressure Transducer or Sensor.
Locate within 5 feet (1.5 m) of pump discharge. Install in a ver-
tical position.
8.
SubDrive Connect VFD
9.
Power Supply from Circuit Breaker
. Single phase, 208/230 VAC +/- 10%.
10.
Power to Motor
. Three-Phase.
11.
Optional Bypass.
For system maintenance.
IMPORTANT:
If the pump is equipped with a built-in pressure switch, the power wires from the
VFD must bypass the pressure switch and connect directly to the motor.
Risk of bodily injury or property damage.
•
Pumps can develop very high pressure in some situations. Always install a pressure relief
valve able to pass full pump flow at 100 psi.
•
Install the pressure relief valve near the pressure tank and route to a drain capable of full sys-
tem flow.
Summary of Contents for MonoDrive
Page 1: ......
Page 56: ...SPECIFICATIONS Notes 56 Notes ...
Page 57: ...SPECIFICATIONS Notes 57 Notes ...
Page 58: ...SPECIFICATIONS Notes 58 Notes ...
Page 61: ...SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R Manuel d utilisation ...
Page 120: ...SPÉCIFICATIONS Normes en vigueur 60 Remarques ...
Page 123: ...SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R Manual del propietario ...