![Franklin Electric MonoDrive Owner'S Manual Download Page 11](http://html.mh-extra.com/html/franklin-electric/monodrive/monodrive_owners-manual_2328786011.webp)
PRODUCT INFORMATION
Generator Sizing
11
Generator Sizing
Basic generator sizing for the Franklin Electric SubDrive/MonoDrive system is 1.5 times the maxi-
mum input watts consumed by the drive, rounded up to the next normal-sized generator.
Recommended minimum generator sizes:
IMPORTANT:
Do not use with a Ground Fault Circuit Interrupter (GFCI). If using an externally regu-
lated generator, verify that the voltage, hertz, and idle speed are appropriate to supply the drive.
Model
Generator
Model
Generator
MonoDrive
SubDrive 15
3500 Watts
•
1/2 hp
2000 Watts
SubDrive 20
5700 Watts
•
3/4 hp
3000 Watts
SubDrive 30
7000 Watts
•
1.0 hp
3500 Watts
SubDrive 50
11000 Watts
MonoDrive XT
•
1.5 hp
4000 Watts
•
2.0 hp
5000 Watts