background image

1

INTRODUCTION

EN

This instruction sheet provides you with the information required 
to safely own and operate your Little Giant pump. Retain these 
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality 
workmanship and material, and has been engineered to give you 
long and reliable service. Little Giant pumps are carefully tested, 
inspected, and packaged to ensure safe delivery and operation. 
Please examine your pump carefully to ensure that no damage 
occurred during shipment. If damage has occurred, please 
contact the place of purchase. They will assist you in replacement 
or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE 
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR 
LITTLE GIANT PUMP. KNOW THE PUMP’S APPLICATION, 
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 
INFORMATION. FAILURE TO COMPLY WITH THESE 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!

DESCRIPTION

This pump has been designed to operate in applications such 
as waterfalls, streams, and fountainheads. It can also be used to 
circulate the water in your pond. Unique features of this pump 
line include a non-clogging vortex impeller, auto-resetting thermal 
overload protection, stainless steel motor housing, and the ability 
to pass solids with diameters up to 1.18”/30mm (WGFP-50) or 
1.38”/35mm (WGFP-75 and WGFP-100).

CAUTION:

 To prevent damaging the pump, do not pump 

abrasives such as sand or mud.

SAFETY GUIDELINES

Read all instructions and Safety Guidelines thoroughly. Failure 
to follow the guidelines and instructions could result in serious 
bodily injury and/or property damage.

RISK OF ELECTRICAL SHOCK:

 This pump is supplied with a 

grounding conductor and grounding-type attachment plug. To 
reduce the risk of electric shock, be certain that it is connected 
only to a properly grounded, grounding-type receptacle. A 
separate branch circuit is recommended. Do not remove the third 
prong from the plug. 

RISK OF ELECTRICAL SHOCK:

 This pump has not been certified 

for use in swimming pool areas where people are present in the 
water. Therefore, pump must not be used for this purpose.

WARNING:

 Do not use to pump flammable or explosive fluids 

such as gasoline, fuel oil, kerosene, etc. Pump should only be 
used with liquids compatible with pump component materials. 
Failure to follow this warning can result in property damage, 
personal injury, or death.
The pump motor is equipped with an automatic resetting thermal 
protector and may restart unexpectedly.
Do not handle a pump or pump motor with wet hands or when 
standing on a wet or damp surface, or in water. Do not stand 
in water while changing fuses or insert your finger into the fuse 
socket.
Make certain the unit is disconnected from the power source, all 
liquids are drained, and all pressure released within the system 
before attempting to service the pump.
This appliance has no user-serviceable parts. The motor housing 
of the pump is completely sealed and requires no service. 
Disassembly of the motor housing or alteration of the power cord 
will void all warranties. The power cord on these units cannot be 
replaced.
Conformity with local and state electric codes is mandatory. 
The National Electric Code requires that a ground fault circuit 
interrupter (GFCI) be used in the branch circuit supplying sump, 
utility, effluent and all fountain pumps, pool pumps and other pond 
equipment.
All wiring and electrical work should be done by a qualified 
electrician.
Secure the discharge line before starting the pump. An unsecured 
discharge line will whip, possibly causing personal injury and/or 
property damage.
Do not run the pump dry. It is designed to be cooled by the fluid it 
moves. If the pump is run dry it will become dangerously hot, and 
could cause personal injury and/or damage to the pump.
The pump’s motor housing contains a dielectric oil to aid in 
bearing lubrication and motor heat dissipation. This oil is non-toxic 
to aquatic life. However, suffocation can occur if oil is left on the 
water surface. If oil escapes the motor housing it can be removed 
from the surface quickly by placing newspapers on the water 
surface to soak up the oil.
Do not lift or carry the pump by the power cord. Use the handle 
on top of the pump.

ELECTRICAL CONNECTIONS

 1. Check the pump label for proper voltage required. Do not 

connect the pump to any voltage other than that shown.

 2.  Plug the power cord directly into an electrical outlet.

MODELS • MODÈLES • 

MODELOS

 WGFP-50 • WGFP-75 • 

WGFP-100

115V/60HZ

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]

MODEL

NO.

CATALOG 

NO.

SAFETY 

LISTING

DISCH.

SIZE

HP PH VOLTS HZ AMPS WATTS MOTOR 

TYPE

GPH @ HEAD

SHUT 

OFF

POWER 

CORD

WEIGHT 

(lbs.)

5’

10’

15’

20’

25’

WGFP-50

566068

cCSAus

2” 

FNPT

1/2

1

115

60

7

590

PSC

4280 3520 2780 1830 800

30’

19’

24.8

WGFP-75

566069

cCSAus

2” 

FNPT

3/4

1

115

60

8

847

PSC

4890 4345 3750 3070 2260

36’

19’

26.4

WGFP-100

566070

cCSAus

2” 

FNPT

1

1

115

60

12

1210

PSC

6400 5500 4700 3700 2500

35’

19’

38.2

Table 1 • Tableau 1 • Tabla 1

Summary of Contents for Little Giant WGFP-50

Page 1: ...uipped with an automatic resetting thermal protector and may restart unexpectedly Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface or in water Do not stand i...

Page 2: ...DE CES DIRECTIVES PEUT ENTRA NER DES BLESSURES ET OU DES DOMMAGES MAT RIELS DESCRIPTION Cette pompe a t con ue pour fonctionner dans des applications comme des chutes d eau des ruisseaux et des t tes...

Page 3: ...10 Si la pompe ne fonctionne pas bien consulter la section de d pannage Si le probl me ne peut tre identifi l aide des tapes indiqu es consulter le concessionnaire qui vous a vendu la pompe ou apporte...

Page 4: ...amente en una toma de corriente el ctrica FUNCIONAMIENTO PRECAUCI N esta bomba est dise ada para bombear agua nicamente con una temperatura m xima de 40 C 105 F No bombee l quidos calientes El uso ide...

Page 5: ...5 A Table 2 C Table 2 B Table 2 Figure 1 Figure 1 Figura 1...

Page 6: ...ique et en la secouant avec le refoulement ouvert Desconecte el cord n el ctrico Saque el aire sumergiendo la bomba en una posici n inclinada y sacudi ndola con el descarga abierto Suction screen clog...

Page 7: ...y gives you specific legal rights and you may also have other rights which vary from state to state and country to country The National Electric Code in the USA and similar codes in other countries re...

Page 8: ...istribuidor o vendedor autorizado con una breve explicaci n por escrito del problema Si no existen se as aparentes de abuso por parte del cliente la unidad ser reemplazada o reparada Si se produce una...