27
Problem
Possible Cause
Probable Correction
Check if the water supply pressure is
below 15 psig.
Check water supply; filter may be
restricted.
Cubes are partially
formed or are white
at the bottom.
Not enough water in the
water trough.
Check for a water leak at the water
trough.
The legs are not leveled and
locked
Level and lock the feet. See
“Leveling the Ice Maker”.
Noise during
operation
Certain sounds are normal.
See “Normal Sounds”.
The electricity is off.
Reconnect the power supply line.
The room temperature is out
of the stated range.
Cut off the electricity; let the ice
maker stop working until the
temperature returns to within the
stated range.
The ice storage bin is full of
ice.
Remove some ice; be sure ice-full
probe is free of ice.
The ice maker stops
suddenly while
making ice.
The drainage tray on top of
the compressor is full.
Drain off water by screwing off the
lower drainage nut.
The body of the ice
maker is electrified.
The ground line isn't in the
socket.
Use a socket meeting the required
electrical standard.
Scaling occurs
frequently inside
the machine.
The water is too hard.
Using a water-softening device
installed in front of the water inlet.
The ice maker
makes an alarm
sound regularly.
The drainage tray on top of
the compressor is full.
Drain off water by removing lower
drainage nut or back drainage plug.