16
11-03-2014 / LSC 044 / Rev. 00
5.2 EK MODEL ALARMS OPERATION
LED CORRESPONDING TO THE COFFEE DOSE BUTTON DISPENSING, FLASHING AFTER 5-6 SECONDS:
This alarm is viewed when, during the delivery phase, there is a flow meter malfunction for the delivery group, or if the coffee has been
too finely ground. After checking the grinding fineness, if the problem continues, contact an authorised service centre.
ALL LEDS CORRESPONDING TO ALL DOSES ON ALL TOUCHPADS FLASHING:
The automatic filling function for the boiler tank has been operating for more than 4 minutes (6 minutes for the 3 groups version), total
machine block. To return to the standard operating phase, switch the machine off using the main on/of switch.
If this problem is repeated frequently, contact an authorised Assistance centre.
Summary of Contents for T 200
Page 4: ...2 11 03 2014 LSC 044 Rev 00 ...
Page 22: ...20 11 03 2014 LSC 044 Rev 00 ...
Page 23: ......