7
11-03-2014 / LSC 044 / Rev. 00
• The appliance has
class I protection against electric shocks.
• The noise emitted by the appliance during normal operation is less than
70 dB.
• NOTE: Appliance fitted to operate with gas system. The appliance has been fitted by the manufacturer to operate with
LPG under a
maximum supply pressure of 30 mbar. Adaptation to operate with any other type of gas must be carried out by personnel authorised
by the manufacturer.
Attention!
failure to comply with the above regulations could jeopardise the correct operation and safety of the appliance as well as its
useful lifetime.
2.2 INSTALLATION REQUIREMENTS FOR THE USER
The appliance must be placed on a flat and stable surface and a
surface height for the appliance of no less than 1.2 metres from
the ground. check this important requirement, since the manu-
facturer cannot be considered liable for any damage caused by
the instability of the appliance. While preparing the system, take
into account that a hole is needed in the bearing surface in order
to make all electric and water connections through the opening
below where a water softener will need to be fitted, if recom-
mended by the installation engineer.
A hole of
10 x 10 cm is enough in the area (a) as indicated in
pict. 3.
The machine needs a minimum clearance of:
- height
60 cm.
- width
40 cm.
- depth
40 cm.
Y
X
X
A
2
1 3
4
Fig. 3
Legend:
1 single pole switch
with an opening of at
least 3 mm between
contacts.
2 Water supply tap
3 Drain siphon
4 Gas supply tap (if fit-
ted)
X min. 20 cm.
y min. 40 cm.
Z* min. 10 cm.
*) Distance between the
back of the appliance
and the wall.