Attach the fitting (k).
10.8
Secure the fitting with the grub screw (l).
10.9
Turn on the water supply.
10.10
Check the connections for leaks.
11. Installation (FAR Order No. AQRM311)
Warning!
Use the fitting only with the non-return valves and the grit filters specified.
Failure to observe can result in an increased bacterial load in drinking water and
cause a health risk or even risk of death.
☞
Important!
Before installing, flush the pipes in compliance with DIN 1988.
☞
Important!
When installing the distribution pipes, ensure that a gap of 45 mm is maintained. Drill
the boreholes so that they are exactly in line vertically. The correct distances of the
pipes as well as the positions of the boreholes must not be forced with the mixer
body and the cover.
11.1
Drill 14 mm holes into the distribution pipes (b).
11.2
Place the clamper (c) and seals on the pipes, and then screw-fasten from the rear
with the clamp cover (a).
☞
Apply grease to the O-rings on the guide bushing!
11.3
Insert the grit filters (d) and the guide bushings (e) into the clamper (c).
11.4
Slide the fitting (g) on to the guide bushings.
11.5
Secure the fitting with the grub screw (f).
11.6
Turn on the water supply.
11.7
Check the connections for leaks.
12. Installation (FAR Order No. AQRM312)
Warning!
Use the fitting only with the non-return valves and the grit filters specified.
Failure to observe can result in an increased bacterial load in drinking water and
cause a health risk or even risk of death.
☞
Important!
Before installing, flush the pipes in compliance with DIN 1988.
☞
Important!
When installing the distribution pipes, ensure that a gap of 45 mm is maintained. Drill
the boreholes so that they are exactly in line vertically. The correct distances of the
pipes as well as the positions of the boreholes must not be forced with the mixer
body and the cover.