![Frank FOM 1024 MSE-Z Operating Instructions Manual Download Page 52](http://html1.mh-extra.com/html/frank/fom-1024-mse-z/fom-1024-mse-z_operating-instructions-manual_2326765052.webp)
52
6.7
Spraying with cleaning agents/Preserving agents
Set dosing valve to the desired dosing position. Final concentration of the cleaning and
preserving agent in the water jet according to the following table:
Formulation concentration 1 : 10 (1 part cleaning agent, 10 parts water)
Percentage of final concentration of cleaning agent in the water jet
If higher concentrations are required, the formulation of the cleaning agent has to be
increased.The maximum suction height for the cleaning agent is 1 m. The suction baskets
must be located below the cleaning agent level in the tank. The desired cleaning agent A or
B can be selected on the button of the control box at the washing bay.
A T T E N T I O N !
When the cleaning agent tank is empty, shut the corresponding dosing valve. Do not select
the programme with the empty tank, as air will be sucted which can damage the pump.
Dosing valve position
High pressure stage HD
FOM 918
FOM 1024
FOM 1415
1
0,21
-
-
2
0,34
0,04
0,10
3
0,38
0,10
0,16
4
0,42
0,17
0,21
5
0,46
0,20
0,26
6
0,50
0,25
0,27
7
0,53
0,30
0,31
8
0,54
0,33
0,34
9
0,56
0,35
0,38
10
Steam stage D
1
0
-
-
2
0,43
-
-
3
0,58
0,13
0,17
4
0,66
0,26
0,24
5
0,70
0,35
0,37
6
0,76
0,42
0,44
7
0,81
0,56
0,55
8
0,86
0,65
0,58
9
0,91
0,76
0,65
10
0,93
0,86
0,79