3.3.8 Burner nozzle
Contaminated fuel oil can block up the nozzle, can cause burning disturbances and
inadmissible emission values so that the nozzle has to be cleaned by means of a nozzle
filter or must be exchanged, In case exchange of a nozzle is necessary, only the type in
regulation to this machine may be used.
3.3.9 Fuel preheater
The fuel preheater i spart of the blast connection. In case of a defective fuel preheater
detach wire in the socket of the oil firing controller and exchange preheater.
3.3.10 Ignition transformer
The ignition transformer is attached to the burner housing.
For dismanteling:
Detach wire in the socket of the oil firing controller. Remove ignition cable from the ignition
electrodes and screw off ignition transformer.
4. Installation
4.1 Location
The machine must not be installed and operated In fire and explosion hazard
areas.
Frost protection
The machine, the long-distance pipings and the washing bays
have to be installed in such a manner to protect them from frost.
The machine is designed for stationary installation on a solid wall.
The satisfactory solidity of the wall must be checked and approved by an expert
on site. If there is no sufficient solidity of the wall for wall installation, the machine
is to be mounted on a scaffolding. Machines with oil atomizing burners must be
installed in rooms only which comply with the local firing requlations resp. to the
local heating room regulations.
DThe room must have appropriate dimensions and must be equipped in such a manner
that exhaust gas duct, aeration and deaeration are guaranteed and a proper installation is
possible.
The machine and the control cabinet must be installed in such a manner that the operation
and all maintenance works can be carried out properly. It is very important that the rear
heating coil cover is easily accessible and demountable
Take care of:
•
Volume
•
Height
•
Minimum air let corss section 410 cm²