1. Application
The wall-mounted FRANK hot water high pressure cleaner module is used for the
cleaning, degreasing, phosphatising, preservind and desinfection of vehicles, machines,
machine components, containers, etc.
2. Technical data
* measured outside, in a distance of 1m from the machine surface and 1,6 m above ground.
Machine type
FOM 918 MSE-Z
FOM 1024 MSE-Z
FOM 1415 MSE-Z
High-pressure stage HD
Maximum flow rate
14,5 l/min
17,0 l/min
23,0 l/min
Maximum working pressure
180 bar
240 bar
150 bar
Admissible working
temperature
80 °C
90 °C
70 °C
Steam stage D
Maximum flow rate
7,5 l/min
9,0 l/min
10,0 l/min
Maximum working pressure
30 bar
30 bar
30 bar
Working temperature
140 °C
140 °C
140 °C
Supply voltage/frequency
400 V 3 N AC 50 Hz
400 V 3 N AC 50 Hz
400 V 3 N AC 50 Hz
Nominal power
consumption
5,3 kW, 11 A
7,5 kW, 15 A
7,5 kW, 15 A
Heat capacity
65 kW
80 kW
80 kW
( 56000 kcal/h)
(68800 kcal/h)
(68800 kcal/h)
Fuel consumption
6,1 kg/h
7,5 kg/h
7,5 kg/h
(at continuous operation and
max. operating temperature)
(7,3 l/h)
Heizöl EL, DIN 51603
(9,0 l/h)
(9,0 l/h)
Sound level
max. 80,5 dB (A) *
max. 80,5 dB (A) *
max. 80,5 dB (A) *
Dimensions
Module
Length
1000 mm
1000 mm
1000 mm
Width
825 mm
825 mm
825 mm
Height
580 mm
580 mm
580 mm
Master control cabinet
380x380x210 mm
380x380x210 mm
380x380x210 mm
Weight
Without packing
215 kg
225 kg
225 kg
With packing
285 kg
295 kg
295 kg