FRANCO 2408001 Instruction Manual For Use And Maintenance Download Page 4

FRANCO s. r. l.                                                                                                                                         Instruction Manual AP 

 

UNIT OF MEASUREMENT 

The units of measurement used are those of the International System (SI). 
 

1.4 Keeping and updating the instruction manual 

 

The  instruction  manual  must  be  kept  with  care  and  must  accompany  the  machine  in  all  changes  of 
ownership that it may undergo during its life. Parts must not be removed, torn off or arbitrarily modified. 
The manual should be stored in an environment protected from moisture and heat and in the immediate 
vicinity of the machine to which it refers. The manufacturer can provide additional copies of the machine 
instruction manual at the user's request. You can request this by writing to 

[email protected].

 

The  manufacturer  reserves  the  right  to  modify  the  design  and  make  improvements  to  the  machine 
without notifying the customer, and without updating the manual already delivered to the user. However, 
in  the  event  of  changes  to  the  machine  installed  at  the  customer's  premises,  agreed  with  the 
manufacturer and involving the modification of one or more chapters of the instruction manual, it will be 
the manufacturer's responsibility to send the affected users the chapters affected by the change. 
It is the responsibility of the user to replace the old chapters, homepage and table of contents with the 
new ones in all copies owned. 
 
The manufacturer is responsible for the 

original Italian language version

; in case of doubts regarding 

the  translated  versions,  please  refer  to  the  Italian  language  and  contact  the  manufacturer 

(

[email protected]) for verification. 

 

1.5 Addressees 

 

This  manual  is  intended  for  the  installer,  operator  and  qualified  personnel  authorised  to  service  the 
machine. 
OPERATOR: means the person(s) in charge of installing, operating, adjusting, cleaning, repairing and 
moving a machine and performing the simplest maintenance operations; 
QUALIFIED  PERSONNEL/QUALIFIED  WORKMAN:  this  refers  to  those  persons  who  have  attended 
specialisation  courses,  training,  etc.  and  have  experience  in  the  installation,  commissioning  and 
maintenance, repair, transport of the machine. 

 

The machine is intended for industrial use, and therefore professional and not general use, so its use 
must be entrusted to 

qualified persons, 

in particular who  

 

  have reached the age of majority; 

  They are physically and mentally fit to perform work of particular technical difficulty; 

  Have been properly instructed in the use and maintenance of the machine; 

  They were judged by their employer to be fit to perform the task entrusted to them; 

  Be able to understand and interpret the operator's manual and safety instructions; 

  They are familiar with emergency procedures and their implementation; 

  Possess the ability to operate the specific type of equipment; 

  Be familiar with the specific rules of the case; 

  Have understood the operating procedures defined by the machine manufacturer. 

 

The appliance may be used by persons with reduced physical, sensory or mental capabilities, or lack of 
experience or the necessary knowledge, provided that they are supervised or have received instructions 
concerning the safe use of the appliance and understanding of the dangers involved.  
 

1.6 Pictograms 

 

This section explains the meaning of the pictograms indicating the operator's qualification, the state of 
the machine, the hazards and the obligations/prohibitions to be observed. Their use makes it possible 
to quickly and unambiguously provide the information required for the correct use of the machine in safe 
conditions. 

 
 
 
 

Summary of Contents for 2408001

Page 1: ...NCE AP HOT WATER HEATERS T R A N S L AT I O N O F O R I G I N A L I N S T R U C T I O N S E N G L I S H Read this manual carefully before install and operate the machine Manual version 00 2022 Franco...

Page 2: ...1 12 Warranty 9 1 13 Manufacturer s identification data 9 1 14 Declarations 9 1 15 Declaration of conformity 10 2 INSTALLATION 11 2 1 Preliminary Operations 11 2 2 Positioning 11 2 3 Electrical conne...

Page 3: ...could be irreparably damaged o Do not use accessories spare parts and or components not specified supplied by the manufacturer o Avoid touching the device with wet and or damp hands o Do not pull on t...

Page 4: ...nnel authorised to service the machine OPERATOR means the person s in charge of installing operating adjusting cleaning repairing and moving a machine and performing the simplest maintenance operation...

Page 5: ...rating it with protections disabled working on mechanical parts to carry out the necessary adjustments maintenance and repairs Typically he is not qualified to work on electrical systems where voltage...

Page 6: ...e a PROHIBITION OBLIGATION Pictogram Description Dangerous electrical voltage General danger Danger hot surfaces Do not remove safety devices Prohibition of cleaning oiling greasing repairing or adjus...

Page 7: ...ical corrosion and acid and tensile strength The fans used on the AP series are single phase 4 or 6 pole axial fans with condenser with IP54 protection for the AP15 and AP25 versions IP44 The motors h...

Page 8: ...he machine by checking that there are no visibly damaged parts Do not dispose of packaging elements in the environment they should be placed in appropriate collection places AP unit heaters can be rai...

Page 9: ...does not cover all parts damaged by transport bad or incorrect maintenance neglect incapacity for use improper use tampering by unauthorised personnel and in any case by causes beyond Franco s r l s...

Page 10: ...Trade name Space heating or cooling Intended use complies with the following European Directives 2006 42 EC Machinery Directive 2014 35 EU Low Voltage Directive 2014 30 EU Electromagnetic Compatibili...

Page 11: ...rking position with a suitable suspension fixing system the hole spacing is shown in figure 2 2 1 AP15 AP25 AP30 AP35 AP40 AP50 AP60 AP70 AP80 AP100 Fig 2 2 1 Position of holes for suspension staffing...

Page 12: ...hermal system must be adapted to the characteristics of the appliances in use and comply with the regulations in force 3 OPERATION 3 1 Preliminary Operations Before putting the unit heater into operat...

Page 13: ...n the exchanger with the help of a stiff bristled brush rubbing the fins gently taking care not to damage them In the event of unusual noises and vibrations check the tightness of screws and bolts Use...

Page 14: ...to push out the fittings fig 4 3 3 Unscrew the connections with a parrot spanner while holding the fittings on the coil with a 33 on AP30 AP35 AP40 or 41 on AP50 AP60 AP70 AP80 AP100 spanner fig 4 4...

Page 15: ...anel to the air heater s supply outlet see Fig 4 4 1 and tilt the flaps to direct the air flow Wall mounting brackets code 2403300 L shaped brackets are available to facilitate wall mounting Attach th...

Page 16: ...8 85 AP50 29 5 1 1 879 737 430 482 580 148 85 AP60 32 5 1 1 879 737 430 482 580 148 85 AP70 32 5 1 1 879 737 430 482 580 148 85 AP80 39 6 42 1 879 737 430 482 580 148 85 AP100 39 6 42 1 879 737 430 48...

Page 17: ...4 6 500 CORRECTION COEFFICIENT PT kW TWI TWO T 10 C TAI 85 C 75 C 70 C 60 C 60 C 50 C 50 C 40 C 15 C 1 52 1 27 1 10 0 93 10 C 1 43 1 18 1 01 0 84 5 C 1 34 1 09 0 93 0 76 0 C 1 25 1 01 0 84 0 68 5 C 1...

Page 18: ...912 5 1 158 3 5 000 AP100 70 48 60 602 52 2 3 100 0 7 257 4 6 500 CORRECTION COEFFICIENT PT kW TWI TWO T 20 C 90 C 70 C 80 C 60 C 70 C 50 C 60 C 40 C 50 C 30 C TAI AP15 AP25 AP30 AP100 AP15 AP25 AP30...

Page 19: ...9 80 19 34 15 97 5 117 18 1 205 3 5 000 AP100 35 64 23 12 16 94 6 121 24 8 333 4 6 500 CORRECTION COEFFICIENT PT kW TAI AP15 AP25 AP30 AP35 AP40 AP50 AP60 AP70 AP80 AP100 24 C 0 60 0 50 26 C 0 80 0 76...

Page 20: ...1 94 1 94 26 27 335 1 0 27 2 3 500 AP35 2 34 2 34 26 55 403 1 4 52 3 5 000 AP40 2 86 2 86 26 63 493 1 9 85 4 6 500 AP50 3 47 3 47 24 92 598 0 8 54 2 3 500 AP60 4 03 4 03 25 49 694 1 0 105 3 5 000 AP7...

Page 21: ...1 FAN AP 15 25 2 6001600 4 TBEI SCREW M6x16 INOX ISO 7380 3 6001000 6 TE SCREW M4x10 STAINLESS STEEL 4 6003008 4 6 STAINLESS STEEL WASHER 5 2400001 1 STAINLESS STEEL COVER AP 15 25 6 2404001 1 BODY AP...

Page 22: ...CHANGER AP 30 35 40 2401003 1 HEAT EXCHANGER AP 50 60 70 2401004 1 HEAT EXCHANGER AP 80 100 4 2401506 1 COMPLETE COVER AP 30 100 5 6003500 6 SCREW AUTOF TC 6 3x22 UNI 6954 6 8101003 2 NIPPLE 1 AP 30 3...

Page 23: ...nd qualified personnel using suitable personal protective equipment Before carrying out any work disconnect the power supply and cut off the water supply PROBLEM CAUSE SOLUTION The machine does not st...

Page 24: ...n Manual AP 24 FRANCO s r l Headquarters and factory Via Nazionale n 80 12010 CERVASCA CUNEO Italy Tel 39 0171 611663 www francosrl com info francosrl com For enquiries or reports please contact us at...

Reviews: