background image

Montfort Mk2 - Model 1340502

Technical manual "1295" 

3

1.1. Package

• 1 package : stove.

1.2. Optional equipment

• Kit air intake 

1.3. General characteristics

1.4. Description

Multifuel stove, in conformity with 

EN 13240

•  Intermittent-burning heating appliance.

•  Detachable  flue  spigot  for  rear  or  top  chimney 

connection.

• Front loading door fitted with large refractory glass 

panel.

•  Adjustable  air  controls  for  controlling  the  burning 

rate.

• Large ash-pan.
• Air wash system

1.5. Principle of operation

The  “Montfort  MK2”  is  designed  for  operation  with 
closed  door.  Heat  is  mainly  diffused  by  radiation, 
through the window and body of the appliance.
Combustion occurs on the grate, with air in let through 
the top of the combustion chamber.

FUEL : WOOD
Reference 

 ........................................

134 05 02

Nominal heat output ............................. kW  

5

Chimney draft required .......................... Pa   12
Hearth dimensions
- width ............................................... mm   335
- depth ............................................... mm   205
- height .............................................. mm   250
Log dimensions
- lenght maxi ........................................cm 

20

Ash pan capacity ................................litres   2,2
Net weight ............................................ kg   81
Heated Volume .................................... m3   130
Efficiency ...............................................%   78
Co (13% O2) .........................................%  0,13
Mean flue gas temperature .................... °C  296
Dust emission .............................. mg/Nm3 

50

FUEL : ANTHRACITE

Nominal heat output ...................kW ................. 5

Chimney draught required............Pa ................12

Flue gas temperature ..................°C ..............297

Flue gas mass flow .....................g/s ...............6,2

Efficiency .................................... % ................67

Co (13% O2) .............................. % .............0,30

1. Product information

This appliance is meant to burn wood or coal safely

WARNING

Incorrectly installed, this appliance can be dangerous and possibly cause serious accidents.

We recommend that you engage the services of a professional engineer for its installation

and the regular maintenance requirements

Figure 1 - Dimensions in mm

550

450

454

137

409

Ø 100

400

347

Ø 139

Ø 125

240

Summary of Contents for Montfort MK2

Page 1: ...appliance Installation instructions Operating instructions Spare parts Warranty certificate Document n 1295 10 20 03 2012 Technical manual to be saved by the user for future reference Parc d activit s...

Page 2: ...Building Control approval or is installed by a Competent Person registered with a Government approved Competent Persons Scheme HETAS Ltd operate such a Scheme and a listing of their Registered Compete...

Page 3: ...for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of...

Page 4: ...iance with a permanently open air vent in compliance with ventilation requirements stated in Approved Document J Please reference ADJ for further guidance Connection to chimney Stoves may have a choic...

Page 5: ...ove have been carried out correctly and that the chimney has been swept clean is sound and free from any obstructions As part of the stoves commissioning and handover the installer should have shown y...

Page 6: ...gade should be called immediately Do not relight the stove until the chimney and flueway have been cleaned and examined by a professional Permanent air vent The stove requires a permanent and adequate...

Page 7: ...p 8 Cleaning p 8 Maintenance of the chimney p 8 Maintenance of the stove p 8 Recommendations p 9 Trouble shooting p 10 FRANCO BELGE congratulates you on your choice FRANCO BELGE guarantees the quality...

Page 8: ...of the combustion chamber FUEL WOOD Reference 134 05 02 Nominal heat output kW 5 Chimney draft required Pa 12 Hearth dimensions width mm 335 depth mm 205 height mm 250 Log dimensions lenght maxi cm 2...

Page 9: ...asons The installation must be carried out according to the standards and the Building Regulations It is the installer responsability to ensure that the manufacturer s intructions are complied with 2...

Page 10: ...l Building Inspector The flue must be in good condition and must provide sufficient draught The flue must be suitable for the installation of solid fuel burning appliances and comply with Current Buil...

Page 11: ...ls have been removed and are not blocking any of the air passages Check that all removable internal components are correctly installed as they May have moved in transit Note all gaskets glass fiber ro...

Page 12: ...Montfort Mk2 Model 1340502 Technical manual 1295 7 Figure 5 Replacing the parts Figure 5a Figure 5b Figure 5c Figure 5d...

Page 13: ...se of the fume emission has been identified and corrected If necessary seek expert advice Note It is recommended to use a fireguard in the presence of children and also in the presence of old and or i...

Page 14: ...g Figure 6 Slide the secondary air inlet B1 to the right Open the primary air inlet C1 Lay firelighters or rolled up newspapers on the grate with a reasonable quantity if necessary of dry kindling woo...

Page 15: ...ny water splashes or condensation marks these should be cleaned off before they have chance to dry out Ensure that the fuel retainer is installed correctly fig 8 Check that there are no obstructions b...

Page 16: ...uously burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pr...

Page 17: ...e A B C D E F 04 22 262612 Heat shield A B C D E F 01 23 265607 Knob A B C D E F 01 24 270412 Air control flap A B C D E F 01 25 300118 EF Leg A 04 25 300118 77 Leg B 04 25 300118 RJ Leg C 04 25 30011...

Page 18: ...1340502 Technical manual 1295 13 Figure 8 Stove exploded view 36 48 20 30 41 1 24 35 3 50 43 52 9a 42 38 51 28 31 47 12 44 45 19 37 34 3 22 33 26 39 25 15 23 46 40 11 27 10 9b 8 21 21 49 13 4 32 5 5 1...

Page 19: ...upplementary plate A B C D E F 01 43 352168 EF Top plate A 01 43 352168 77 Top plate B 01 43 352168 RJ Top plate C 01 43 352168 RP Top plate D 01 43 352168 RH Top plate E 01 43 352168 MK Top plate F 0...

Page 20: ...Montfort Mk2 Model 1340502 Technical manual 1295 15 Notes...

Page 21: ...ostly vis vis the price of the appliance the decision to replace or repair the appliance will be taken by the vendor Our guarantee is for 2 two years for all appliances with the exception of closed co...

Reviews: