2.1 Warning to the user

All  the  local  and  national  regulations,  and 

in  particular  those  relating  to  national  and 

European  standards,  must  be  observed  when 

installing the appliance.
An  incorrectly  installed  heating  appliance  can 

cause serious accidents

 (chimney fires, burning of 

plastic insulation materials in partition walls, etc.).
This  stove  is  exempted  by  DEFRA  for  burning  wood 

logs  in  UK  Smoke  Control  Areas  (SCA).  DEFRA 

exemption  is  dependent  upon  the  appliance  being 

fitted with a mechanical stop to prevent closure of the 

secondary air control beyond the 25% open position. 

You  should  check  that  this  stop  mechanism  is  fitted 

before  installation  of  the  stove  and  certainly  before 

using the stove in a SCA to burn wood logs. If the stop 

mechanism  is  fitted  then  the  minimum  chimney  flue 

diameter can be 125 mm but if the stop mechanism 

is  not  fitted  then  the  stove  is  not  exempted  and 

the  minimum  chimney  flue  diameter  is  150  mm  in 

accordance with Approved Document J of the building 

regulations.

The insulation of both the appliance and the exhaust 

gas pipe has to be reinforced and done according to 

the Standards and the Bui lding Regulations for safety 

reasons. The installation must be carried out according 

to the standards and the Building Regulations.
It  is  the  installer  responsability  to  ensure  that  the 

manufacturer's intructions are complied with.

2.2. The room

Ventilation

 : To ensure that the appliance operates 

correctly  it  is  vital  that  sufficient  air  is  provided  for 

combustion  purposes.  Check  that  sufficient  air  is 

available  in  the  room  for  combustion.  Il  a  VMC 

(controlled  mechanical  ventilation)  is  present,  the 

room pressure will be low and a non-closing external 

air intake must be installed in addition to the chimney 

itself of a minimum 50 cm2. 

Position of the unit

 : For new installations, select a 

central  position  within  the  house,  to  provide  a  good 

heat distribution around the building.

The heat distribution towards the other rooms will be 

made through the communicating doors.  

These  rooms  must  be  in  negative  pressure  or  must 

include ventilation gratings.

Floor and walls

 : 

Make sure that the floor can support the weight of the

appliance,  it's  flue  and  any  surround.  The  floor  May 

need  to  be  re-inforced  with  e  concrete  screed  to 

distribute  the  weight  load.  The  floor  must  not  be 

made  of  or  covered  with  combustible  materials,  as 

per the Building Regulations. Il combustible material is 

present it will be necessary to install a non-combustible 

covering.

2. Installation instructions

Figure 2 b - Clearances

150

150

150

150

550 mm

525 mm

Figure 2 a - Clearance

Summary of Contents for Montfort MK2

Page 1: ...appliance Installation instructions Operating instructions Spare parts Warranty certificate Document n 1295 10 20 03 2012 Technical manual to be saved by the user for future reference Parc d activit s...

Page 2: ...Building Control approval or is installed by a Competent Person registered with a Government approved Competent Persons Scheme HETAS Ltd operate such a Scheme and a listing of their Registered Compete...

Page 3: ...for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of...

Page 4: ...iance with a permanently open air vent in compliance with ventilation requirements stated in Approved Document J Please reference ADJ for further guidance Connection to chimney Stoves may have a choic...

Page 5: ...ove have been carried out correctly and that the chimney has been swept clean is sound and free from any obstructions As part of the stoves commissioning and handover the installer should have shown y...

Page 6: ...gade should be called immediately Do not relight the stove until the chimney and flueway have been cleaned and examined by a professional Permanent air vent The stove requires a permanent and adequate...

Page 7: ...p 8 Cleaning p 8 Maintenance of the chimney p 8 Maintenance of the stove p 8 Recommendations p 9 Trouble shooting p 10 FRANCO BELGE congratulates you on your choice FRANCO BELGE guarantees the quality...

Page 8: ...of the combustion chamber FUEL WOOD Reference 134 05 02 Nominal heat output kW 5 Chimney draft required Pa 12 Hearth dimensions width mm 335 depth mm 205 height mm 250 Log dimensions lenght maxi cm 2...

Page 9: ...asons The installation must be carried out according to the standards and the Building Regulations It is the installer responsability to ensure that the manufacturer s intructions are complied with 2...

Page 10: ...l Building Inspector The flue must be in good condition and must provide sufficient draught The flue must be suitable for the installation of solid fuel burning appliances and comply with Current Buil...

Page 11: ...ls have been removed and are not blocking any of the air passages Check that all removable internal components are correctly installed as they May have moved in transit Note all gaskets glass fiber ro...

Page 12: ...Montfort Mk2 Model 1340502 Technical manual 1295 7 Figure 5 Replacing the parts Figure 5a Figure 5b Figure 5c Figure 5d...

Page 13: ...se of the fume emission has been identified and corrected If necessary seek expert advice Note It is recommended to use a fireguard in the presence of children and also in the presence of old and or i...

Page 14: ...g Figure 6 Slide the secondary air inlet B1 to the right Open the primary air inlet C1 Lay firelighters or rolled up newspapers on the grate with a reasonable quantity if necessary of dry kindling woo...

Page 15: ...ny water splashes or condensation marks these should be cleaned off before they have chance to dry out Ensure that the fuel retainer is installed correctly fig 8 Check that there are no obstructions b...

Page 16: ...uously burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pr...

Page 17: ...e A B C D E F 04 22 262612 Heat shield A B C D E F 01 23 265607 Knob A B C D E F 01 24 270412 Air control flap A B C D E F 01 25 300118 EF Leg A 04 25 300118 77 Leg B 04 25 300118 RJ Leg C 04 25 30011...

Page 18: ...1340502 Technical manual 1295 13 Figure 8 Stove exploded view 36 48 20 30 41 1 24 35 3 50 43 52 9a 42 38 51 28 31 47 12 44 45 19 37 34 3 22 33 26 39 25 15 23 46 40 11 27 10 9b 8 21 21 49 13 4 32 5 5 1...

Page 19: ...upplementary plate A B C D E F 01 43 352168 EF Top plate A 01 43 352168 77 Top plate B 01 43 352168 RJ Top plate C 01 43 352168 RP Top plate D 01 43 352168 RH Top plate E 01 43 352168 MK Top plate F 0...

Page 20: ...Montfort Mk2 Model 1340502 Technical manual 1295 15 Notes...

Page 21: ...ostly vis vis the price of the appliance the decision to replace or repair the appliance will be taken by the vendor Our guarantee is for 2 two years for all appliances with the exception of closed co...

Reviews: