3. Instructions for user

All  the  local  and  national  regulations,  and 

in  particular  those  relating  to  national  and 

European  standards,  must  be  observed  when 

using the appliance.

Do not run the stove in mild weather with fuel. Under 

certain circumstances such as fog and repeated thaw, 

the  chimney  will  not  draw  sufficiently  and  could 

cause smoke to return to the room which could cause 

asphyxia.  Await  improved  weather  conditions  before 

attempting  to  burn  fuels  again  however  you  can 

continue to use the appliance with Wood.

On  the  first  firing,  a  Small  fire  should  be  lit  and  be 

increased gradually to enable the various components 

to  expand  normally  and  for  the  appliance  to  cure 

correctly.

Note :

 When the fire is lit for the first time, the stove 

may give off fumes from the new paint. This is normal 

but ensure the room is well ventilated during the first 

few hours of operation.

Warning  :

  properly  installed  and  operated  this 

appliance will not emit fumes into the dwelling.

Occasional fumes from de-ashing and re-fuelling may 

occur. Persistent fume emission is dangerous and must

not be tolerated. If fume emission does persist :

Open doors and windows to ventilate room.

Let the fire out and dispose of fuel from the appliance.

Check  for  flue  or  chimney  blockage,  and  clean  if 

required.

Do not attempt to relight the fire until the cause of the

fume  emission  has  been  identified  and  corrected.  If 

necessary seek expert advice.

Note :

 It is recommended to use a fireguard in the 

presence of children, and also in the presence of old 

and/or infirm people.

3.1. Fuel

This appliance is not an incinerator.

Recommended fuel : Wood

• Use hard wood logs, which have been cut for at least 

two years and stored, under shelter.

• Hardwood has a higher calorific value per cu metre 

(oak, ash, maple, birch, elm, beech, etc.).

• Large logs must be split and cut to a usable length, 

before being stored in a sheltered and ventilated place.

We do not recommend the use of Homefire on your 

stove due to the number of glass panels which have 

been effected by this fuel.

We do not recommend the use of Homefire on your 

stove due to the number of glass panels which have 

been effected by this fuel.

Possible fuel : smokeless fuels

• Smokeless fuels, including coolite nuts, phurnacite, 

ancit and extracite.

When using smokeless fuels :

Output : 5 kW

Draught : 12 Pa

Efficiency : 67 %

Co at 13 % of O2 : 0,30 %

Mean flue gas temperature : 297 °C

Those values are obtained at nominal output with a

load of 1,5 kg of phurnacite.

The  manufacturer  will  not  be  responsible  for 

any  damage  caused  to  the  appliance  due  to  the 

incorrect  use  or  installation  of  the  appliance  e.g. 

prohibited  fuel  use  and  any  alterations  made  to 

the appliance which have not been authorised by. 

the manufacturer. 

We recommend that you use 

only  the  manufacturer's  own  brand  spare 

parts.

A

 : Door lock

: Draught control (secondary air inlet)

: Primary air inlet.

D

 : Prehension tool

A

+

C2

B

D

Figure 6 - Operating devices

-

C1

C

Summary of Contents for Montfort MK2

Page 1: ...appliance Installation instructions Operating instructions Spare parts Warranty certificate Document n 1295 10 20 03 2012 Technical manual to be saved by the user for future reference Parc d activit s...

Page 2: ...Building Control approval or is installed by a Competent Person registered with a Government approved Competent Persons Scheme HETAS Ltd operate such a Scheme and a listing of their Registered Compete...

Page 3: ...for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of...

Page 4: ...iance with a permanently open air vent in compliance with ventilation requirements stated in Approved Document J Please reference ADJ for further guidance Connection to chimney Stoves may have a choic...

Page 5: ...ove have been carried out correctly and that the chimney has been swept clean is sound and free from any obstructions As part of the stoves commissioning and handover the installer should have shown y...

Page 6: ...gade should be called immediately Do not relight the stove until the chimney and flueway have been cleaned and examined by a professional Permanent air vent The stove requires a permanent and adequate...

Page 7: ...p 8 Cleaning p 8 Maintenance of the chimney p 8 Maintenance of the stove p 8 Recommendations p 9 Trouble shooting p 10 FRANCO BELGE congratulates you on your choice FRANCO BELGE guarantees the quality...

Page 8: ...of the combustion chamber FUEL WOOD Reference 134 05 02 Nominal heat output kW 5 Chimney draft required Pa 12 Hearth dimensions width mm 335 depth mm 205 height mm 250 Log dimensions lenght maxi cm 2...

Page 9: ...asons The installation must be carried out according to the standards and the Building Regulations It is the installer responsability to ensure that the manufacturer s intructions are complied with 2...

Page 10: ...l Building Inspector The flue must be in good condition and must provide sufficient draught The flue must be suitable for the installation of solid fuel burning appliances and comply with Current Buil...

Page 11: ...ls have been removed and are not blocking any of the air passages Check that all removable internal components are correctly installed as they May have moved in transit Note all gaskets glass fiber ro...

Page 12: ...Montfort Mk2 Model 1340502 Technical manual 1295 7 Figure 5 Replacing the parts Figure 5a Figure 5b Figure 5c Figure 5d...

Page 13: ...se of the fume emission has been identified and corrected If necessary seek expert advice Note It is recommended to use a fireguard in the presence of children and also in the presence of old and or i...

Page 14: ...g Figure 6 Slide the secondary air inlet B1 to the right Open the primary air inlet C1 Lay firelighters or rolled up newspapers on the grate with a reasonable quantity if necessary of dry kindling woo...

Page 15: ...ny water splashes or condensation marks these should be cleaned off before they have chance to dry out Ensure that the fuel retainer is installed correctly fig 8 Check that there are no obstructions b...

Page 16: ...uously burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pr...

Page 17: ...e A B C D E F 04 22 262612 Heat shield A B C D E F 01 23 265607 Knob A B C D E F 01 24 270412 Air control flap A B C D E F 01 25 300118 EF Leg A 04 25 300118 77 Leg B 04 25 300118 RJ Leg C 04 25 30011...

Page 18: ...1340502 Technical manual 1295 13 Figure 8 Stove exploded view 36 48 20 30 41 1 24 35 3 50 43 52 9a 42 38 51 28 31 47 12 44 45 19 37 34 3 22 33 26 39 25 15 23 46 40 11 27 10 9b 8 21 21 49 13 4 32 5 5 1...

Page 19: ...upplementary plate A B C D E F 01 43 352168 EF Top plate A 01 43 352168 77 Top plate B 01 43 352168 RJ Top plate C 01 43 352168 RP Top plate D 01 43 352168 RH Top plate E 01 43 352168 MK Top plate F 0...

Page 20: ...Montfort Mk2 Model 1340502 Technical manual 1295 15 Notes...

Page 21: ...ostly vis vis the price of the appliance the decision to replace or repair the appliance will be taken by the vendor Our guarantee is for 2 two years for all appliances with the exception of closed co...

Reviews: