Commissioning
EMG 1500 Operating Manual
10
Important:
The specified gateway must be located within the subnetwork
concerned. The specified subnet mask must comply with the
IP rules.
4.3.1 Assigning the IP address using „SYSTEM-SW“
It is only possible to assign this address if the program SYSTEM-SW
is installed on the PC.
A further requirement is
also that at least one
project has already been
created with this software.
In this project there is at
least one data collector of
the type EMIS 1500. In
addition, a connection with
this data collector must be
in existence.
An additional bus coupler
can be added by clicking
the right mouse button
with the cursor on the data
collector. A dialog box is
displayed in which the
coupler type “EMG-PN”
must be selected. The
device can then also be
assigned a name and a
descriptive text.
•
Clicking the Configure
button informs the EMIS
1500 how the EMG
1500-PN
is
to
be
addressed.
•
Clicking the IP Settings
button displays the EMG-SW configuration software, enabling the
user to assign the EMG 1500-PN an IP address (see section 4.3,
page 9).