17
U35 FPI Direct Vent Gas Insert
Gas
In
Piezo
Ignitor
Thermocouple
In
Brown
Black
Red
White
To
Thermocouple IN
Pilot
Assembly
Thermostat
(Optional)
(Millivolt)
Remote
Receiver
(Optional)
(Millivolt)
Remote Transmitter
(Optional)
"S.I.T" Valve
ON
OFF
Regency
HI
LO
OFF
ON
P
IL
O
T
Burner
ON
OFF
Ground
Neutral
Live
Black
Black
Red
Minimum Convection
Air Temp. Switch
ON
OFF
Rotary Speed
Control
120V AC
60 Hz
Green
Ground
Fan
Gas
Pilot
Thermopile
Thermocouple
Electrode
Lockwasher
Fan
ground
Power
cord
ground
wire
Star
washer
Nut
Nut
#8 Ground Lug
Star
washer
WIRING DIAGRAM
INSTALLATION
CAUTION: Label all wires prior to
disconnection when servicing con-
trols. Wiring errors can cause im-
proper and dangerous operation.
This heater does not require a 120V A.C.
supply for operation. However, a 120V A.C.
power supply is needed for the fan/blower
operation.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged (ground-
ing) plug for your protection against shock hazard and
should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the
grounding prong from this plug.
Caution: Ensure that
the wires do not touch
any hot surfaces and
are away from sharp
edges.
Use the FPI Remote Control Kit approved for this
unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall to
install the receiver and the receptacle box
(protection from extreme heat is very impor-
tant). Run wires from the fireplace to that
location. Use Thermostat Wire Table.
2) Connect the wires as per the wiring dia-
grams below.
CAUTION
Do not connect the millivolt
remote control wires
to the 120V wires.
3) Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
OPTIONAL REMOTE CONTROL
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired,
follow the wiring diagram below. Note: the
wires are connected to the "TH" on the gas
valve. Use the table below to determine the
maximum wire length. FPI offers an optional
programmable thermostat but any 250-750
millivolt rated non-anticipator type thermostat
that is CSA, ULC or UL approved may be used.
It is recommended that the thermostat
be installed on an interior wall.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.