11
U35 FPI Direct Vent Gas Insert
Diagram 4
Diagram 5
Diagram 3
INSTALLATION
9) Attach the brass trim to the faceplate by
drilling a 1/8" hole through into the faceplate
using the hole in the trim as a guide. Fasten
the trim to the faceplate panels using the
plated screws. Diagram 4.
10) Attach the faceplate panels to the insert
body using the 4 remaining black screws.
Diagram 5.
11) Push the FPI logo plate into the two holes in
the bottom left corner of the faceplate.
Diagram 1
Use the hook to pull the spring out until you can
put the hook into the slot on the bottom door
bracket. Repeat for 2nd spring. See diagram 3.
Diagram 3
Diagram 2
STANDARD
FLUSH DOOR
The standard flush door comes with a
black frame. To install the frame, simply hook
the top door flange onto the top of the unit and
swing the door towards the unit, diagram 1. Be
careful that the
glass gasket does
not roll up; there
must be a gap be-
tween the gasket
and the door lip to
ensure that the
door sits securely
on the unit. Dia-
gram 2.
To remove the flush door, reverse the above
steps.
NOTE: The chain must rest on TOP of the gas
inlet pipe never under it.
OPTIONAL FLUSH
TRIM
Attach 2 round magnets to the back of the top
trim piece and the other 2 to the bottom trim
piece, then attach trim to the top and bottom of
Flush door.
FLUSH LOUVERS
1) The top louver is held in place by friction fit,
if the louver needs to be adjusted; bend the
bracket out as shown in the diagram.
2) Install the Spring Hinges on the left and right
side of the bottom of the Firebox using 2
screws per hinge.
3) Place the Bottom Louver near the hinge. Flip
hinge over the Bottom Louver and secure
using 3 screws.
Bottom Louver
Hinge
Location