8
www.fosterrefrigerator.com
Service Level Parameters
M
nemomic
Description
MDL
Do not adjust
SPL
Minimum limit for SetPoint
setting
SPH
Maximum limit for SetPoint
setting
SP
Setpoint
Temperature value to be maintained in the product
HY0
Thermostat OFF -> ON
differential
In Cooling Mode - ‘MDL’ = ‘HYS’
HY1
Do not adjust
CMD
Compressor start delay ‘run’
mode
The time between mains power being applied and the compressor starting when in ‘run’
mode (i.e. following a mains power cut)
CRT
Compressor rest time
Minimum time compressor is switched off following cycle operation (i.e. pull down, hot
gas defrost)
CT1 Compressor output on time
Followed by ‘CT2’ when probe Ta (T1) is faulty
CT2 Compressor output off time
Followed by ‘CT1’ when probe Ta (T1) is faulty
PB
Do not adjust
IT
Do not adjust
DT
Do not adjust
CT
Do not adjust
AR
Do not adjust
CMS
Do not adjust
CRS
Do not adjust
CRD
Do not adjust
CDS
Do not adjust
CFF
Do not adjust
CSS
Do not adjust
CSO
Do not adjust
CST
Do not adjust
DFM
Defrost start mode
Defrost start mode
‘NON’ - defrost function is disabled - no defrosts will occur
‘TIM’ - Time. Defrosting occurs on a time base determined by ‘DFT’, accumulated only in
run mode
‘FRO’ - Do not use
‘DoD’ - Do not use
‘TAD’ - Do not use
DFT
Time interval between defrosts When this time has elapsed since the previous defrost (in run mode), a new defrost cycle
is initiated
DSP
Do not adjust
DST
Do not adjust
DMI
Do not adjust
DLI
Defrost end temperature
DTO Maximum defrost duration
DTY
Defrost type
‘OFF’ - Off cycle defrost (Compressor and Heater OFF)
‘ELE’ - Electric defrost (Compressor OFF and Heater ON)
‘GAS ‘ - Hot gas defrost (Compressor and Heater ON)
DSY
Defrost start synchronization
‘OFF’ - none. The defrost will occur without delay
‘LO’ - defrost start will be postponed to compressor cut-out (SOD = max delay)
HI’ - defrost start will be postponed to compressor cut-in (SOD = max delay)
SOD
Do not adjust
DPD
Evaporator pump down
At the beginning of defrost, defrost outputs (determined by ‘DTY’) are ‘OFF’ for ‘DPD’
seconds
DRN
Pause after defrost (evaporator
drain down time)
DDM
Defrost display mode.
RT’ - the real / actual temperature
LT’ - the last temperature displayed before defrost initiation
SP’ - the setpoint value
dEF’ - ‘dEF’
Service Level Menu
To access service level menu, press button 3 then press and hold buttons 2 and 4 for 5 seconds and the display will show ‘MDL’. Press button 3 to
display the current value. If it is required to amend the value use buttons 2 and 4 followed by button 3 to save the new value.
Summary of Contents for ECORPO G3 EP1440G
Page 20: ...20 www fosterrefrigerator com Wiring Diagrams EP700H Integral Condensing Unit...
Page 21: ...21 G3 Cabinets Service Manual EP700H Remote Condensing Unit...
Page 22: ...22 www fosterrefrigerator com EP700G Integral Condensing Unit...
Page 23: ...23 G3 Cabinets Service Manual EP700G Remote Condensing Unit...
Page 24: ...24 www fosterrefrigerator com EP700P Integral Condensing Unit...
Page 25: ...25 G3 Cabinets Service Manual EP700P Glass Door Integral Condensing Unit...
Page 26: ...26 www fosterrefrigerator com EP700F Integral Condensing Unit...
Page 27: ...27 G3 Cabinets Service Manual EP700F Remote Condensing Unit...
Page 28: ...28 www fosterrefrigerator com EP700M EP700L Integral Condensing Unit...
Page 29: ...29 G3 Cabinets Service Manual EP700M EP700L Remote Condensing Unit...
Page 30: ...30 www fosterrefrigerator com EP700HH Integral Condensing Unit...
Page 31: ...31 G3 Cabinets Service Manual EP700HH Remote Condensing Unit...
Page 32: ...32 www fosterrefrigerator com EP700HL Integral Condensing Unit...
Page 33: ...33 G3 Cabinets Service Manual EP700HL Remote Condensing Unit...
Page 34: ...34 www fosterrefrigerator com EP700LL Integral Condensing Unit...
Page 35: ...35 G3 Cabinets Service Manual EP700LL Remote Condensing Unit...
Page 36: ...36 www fosterrefrigerator com EP820HU Integral Condensing Unit...
Page 37: ...37 G3 Cabinets Service Manual EP1440H Integral Condensing Unit...
Page 38: ...38 www fosterrefrigerator com EP1440H Remote Condensing Unit...
Page 39: ...39 G3 Cabinets Service Manual EP1440G Integral Condensing Unit...
Page 40: ...40 www fosterrefrigerator com EP1440G Remote Condensing Unit...
Page 41: ...41 G3 Cabinets Service Manual EP1440M EP1440L Integral Condensing Unit...
Page 42: ...42 www fosterrefrigerator com EP1440M EP1440L Remote Condensing Unit...
Page 43: ...43 G3 Cabinets Service Manual...