background image

Installation & Operation Manual

Chef Base  

(R290)

Please read this manual completely  before installing or operating this unit!

Blueair FSE reserves the right to make product modification at any time. 

Specifications and Designs are subject to change without notice.

IMPORTANT SAFETY INSTRUCTION (SAVE THESE INSTRUCTIONS)

Visit our website at 

www.blueairfse.com

BACB36-HC    BACB36M-HC
BACB48-HC    BACB48M-HC
BACB53-HC    BACB53M-HC
BACB72-HC    BACB72M-HC
BACB74-HC    BACB74M-HC
BACB84-HC    BACB84M-HC
BACB86-HC    BACB86M-HC

BACB96 -HC    BACB96M-HC

Summary of Contents for BACB36-HC

Page 1: ...e product modification at any time Specifications and Designs are subject to change without notice IMPORTANT SAFETY INSTRUCTION SAVE THESE INSTRUCTIONS Visit our website at www blueairfse com BACB36 HC BACB36M HC BACB48 HC BACB48M HC BACB53 HC BACB53M HC BACB72 HC BACB72M HC BACB74 HC BACB74M HC BACB84 HC BACB84M HC BACB86 HC BACB86M HC BACB96 HC BACB96M HC ...

Page 2: ...onwide Sevice Network Toll Free 1 866 677 8500 TEL 310 808 0102 FAX 310 808 0242 Visit our website at www blueairfse com Specifications _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 Installation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 Maintenance Cleaning _ _ _ _ _ _ _ _ _ _ 4 Operation _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5 Troubleshooting _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 Installing Casters _ _ _ _ _ _ _ _ _ _...

Page 3: ...15P Amps 3 0 3 0 3 0 3 0 3 0 3 5 3 5 3 5 Range of Temperature 32 F to 41 F Refrigerant R290 3 Models that has M on last digit of the Model name have V shape of Top Specifications and Designs are subject to change without notice The name plate including Serial No is located on the upper left side of the cabinet interior CAUTION Risk of Fire or Explosion Flammable Refrigerant Used Consult instructio...

Page 4: ...asket should be cleaned to avoid maintain proper sealing 1 INDOOR USE ONLY 1 This unit is intended for indoor use only 2 FOR LOCATION 1 Be sure that the location is strong enough to support the total weights of unit and the content 2 Keep the unit away from sunlight and other heat generating equipment 3 The minimum clearance between the back of the unit and wall should be 7 inches at least 3 INSTA...

Page 5: ...et interior 2 The controller has been preset NORMAL position at the factory 3 Set the control knob toward COOL for higher temperature and COLD for lower temperature 4 The thermostat controls compressor s ON OFF by sensing inside temperatures of cabinet 5 The unit is equipped with an off cycle defrost ...

Page 6: ...turn it clockwise to set a desired temperature Performance Issue Move the unit from direct sunlight Move the unit away from heat generating devices Install the unit in a well ventilated area with at least 7 Inches of clearance on all sides Clean the condenser if heavy dust is collected Clear contents from blocking the air duct in the interior Check the temperature controller for incorrect setting ...

Page 7: ...7 1 Remove the outer packing 2 Install the casters in the area 3 Maker sure that castors with brakes should be installed in front ...

Page 8: ...8 ...

Page 9: ...______________________ Extended Warranty Option Additional 1 Year Parts Labor extended Warranty available Please make check payable to TITAN and Return with this registration card 口 Yes I would like the extended warranty 口 No I would not like the extended warranty Signature of Business Owner ______________________________ Date _____________________ Zip ________ __ Customer Name ___________________...

Page 10: ...Blueair FSE LLC 223 W Rosecrans Ave Gardena CA 90248 Toll Free 1 866 677 8500 TEL 310 808 0102 FAX 310 808 0242 Visit our website at www blueairfse com ...