Fortinet FortiController-5913C System Manual Download Page 5

FortiController-5913C Session-Aware Load Balancing Cluster (SLBC) System Guide
10-500-259409-20160210

5

http://docs.fortinet.com/

FortiController-5913C

FortiController-5913C system

The FortiController-5913C is an Advanced Telecommunications Computing Architecture 
(ATCA) compliant session-aware load balancing hub/switch board that distributes IPv4 
TCP and UDP sessions to multiple FortiGate-5000-series boards (called workers) over 
the FortiGate-5144C chassis fabric backplane. The FortiController-5913C includes two 
front panel 100Gbps C

 

formfactor pluggable 2 (CFP2) interfaces (F1 and F2) for 

connecting to 100Gbps networks. The FortiController-5913C forms a session-aware load 
balanced cluster and uses FortiASIC DP processors to load balance millions of sessions 
to the cluster, providing up to 40 Gbps of traffic to each cluster member (each worker). 
Performance of the cluster shows linear improvement if more workers are added. 

Clusters can also be formed with one or two FortiController-5913Cs and up to 12 
workers. All of the workers must be the same model. Currently FortiGate-5001B, 
FortiGate-5001C, FortiGate-5101C, and FortiGate-5001D workers are supported. 
FortiGate-5001C and FortiGate-5001D workers can handle up to 40 Gbps of traffic. 
FortiGate-5001B and FortiGate-5101C workers can handle up to 10

 

Gbps. 

The FortiController-5913C can also provide 40-gigabit fabric and 1-gigabit base 
backplane channel layer-2 switching in a dual star architecture.

You should install the FortiController-5913C in a FortiGate-5144C chassis to meet 
FortiController-5913C power requirements, to have access to a 40G fabric backplane,

 

and to have enough slots for the number of workers that the FortiController-5913C can 
load balance sessions to.

In all ATCA chassis, FortiController-5913Cs are installed in the first and second 
hub/switch slots (usually slots 1 and 2). A single FortiController-5913C should be 
installed in slot 1 (but you can install it in slot 2). If you add a second 
FortiController-5913C it should be installed in slot 2.

See th

FortiGate-5000 Compatability Guide

 for up-to-date information about 

FortiGate-5000 series chassis and other components that are compatible with the 
FortiController-5913C.

Figure 1: FortiController-5913C front panel

Extraction

Lever

Retention

Screw

Extraction

Lever

Retention

Screw

OOS
LED

STA
LED

PWR
LED

F1 and F2

100Gbps Fabric Channel 

CFP2 Network

Interfaces (data)

B1 and B2

10Gbps Base Channel

SFP+ Interfaces

(heartbeat and

management)

MGMT

10/100/1000 Copper

Management Interface

RJ-45

Console

USB

IPM

LED

(board

position)

Summary of Contents for FortiController-5913C

Page 1: ...ortiGate 5000 series documents are available from the FortiGate 5000 page of the Fortinet Technical Documentation web site http docs fortinet com Access to Fortinet customer services such as firmware...

Page 2: ...t is grounded This includes supply connections e g power strips not only direct connections to the branch circuit Mise la terre Assurez vous que tout l quipement est mis la terre Ceci comprend les con...

Page 3: ...own and Removing a FortiController 5913C board 17 Resetting a FortiController 5913C board 19 Troubleshooting 20 FortiController 5913C does not startup 20 FortiController 5913C status LED is flashing d...

Page 4: ...n 28 Customer service and support 28 Fortinet products End User License Agreement 28 Regulatory Notices 30 Federal Communication Commission FCC USA 30 Industry Canada Equipment Standard for Digital Eq...

Page 5: ...FortiGate 5001D workers can handle up to 40 Gbps of traffic FortiGate 5001B and FortiGate 5101C workers can handle up to 10 Gbps The FortiController 5913C can also provide 40 gigabit fabric and 1 gig...

Page 6: ...istribute sessions to workers installed in chassis slots 3 to 14 The speed of these interfaces cannot be changed You may need to use attenuators on these single or split interfaces if their optical po...

Page 7: ...shing Amber Network activity Off No link is established B1 and B2 Green The correct cable is connected to the interface and the connected equipment has power Flashing Green Network activity at the int...

Page 8: ...he same chassis can be added for redundancy or to increase the number of network interfaces You can also add a second chassis for chassis redundancy Table 2 FortiController 5913C connectors Connector...

Page 9: ...ons One FortiController 5913C and up to 12 workers The FortiController 5913C receives all sessions and load balances them to the workers If the FortiController 5913C fails the cluster fails Two FortiC...

Page 10: ...ler 5913C and up to 12 workers in each chassis The FortiController 5913C in one chassis receives all sessions and load balances them to the workers in that chassis If that FortiController 5913C fails...

Page 11: ...m a two chassis SLBC where each chassis would include a FortiController 5913C in slot 1 and optionally a second FortiController 5913C in slot 2 You then install the workers in slots 3 and up in each c...

Page 12: ...Controller 5913C session aware load balancing SALB FortiController 5913C system FortiController 5913C Session Aware Load Balancing Cluster SLBC System Guide 12 10 500 259409 20160210 http docs fortine...

Page 13: ...nstall SR SFP transceivers for normal operation of FortiController 5913C B1 and B2 front panel interfaces The FortiController 5913C ships with two SR SFP transceivers You can also configure the B1 and...

Page 14: ...right bottom of the FortiController 5913C front panel The mounting components on the left top of the front panel are the same but reversed The FortiController 5913C mounting components align the boar...

Page 15: ...ard power on and start up correctly FortiController 5913C boards are hot swappable The procedure for inserting a FortiController 5913C board into a chassis slot is the same whether or not the chassis...

Page 16: ...sides of the chassis slot Closing the handles draws the FortiController 5913C board into place in the chassis slot and into full contact with the chassis backplane The FortiController 5913C front pane...

Page 17: ...ontroller 5913C mounting components described in FortiController 5913C mounting components on page 14 to remove a FortiController 5913C board from an ATCA chassis slot FortiController 5913C boards are...

Page 18: ...s flashing and becomes solid blue 7 Open the handles to their fully open positions Opening the handles turns off the microswitch turns off all LEDs and ejects the board from the chassis slot You need...

Page 19: ...the FortiController 5913C board to use this procedure To complete this procedure you need An ATCA chassis with a FortiController 5913C board installed An electrostatic discharge ESD preventive wrist...

Page 20: ...ortiController 5913C board is receiving power and the handles are fully closed and you have restarted the chassis and the FortiController 5913C still does not start up the problem could be with FortiO...

Page 21: ...hould indicate that the boards are functioning normally This chapter includes the following topics SLBC licensing Connecting to the FortiController 5913C GUI Connecting to the FortiController 5913C CL...

Page 22: ...alancing settings By default you can connect to the FortiController 5913C GUI by browsing to https 192 168 1 99 Connecting to the FortiController 5913C CLI You can connect to the FortiController 5913C...

Page 23: ...ler 5913C board in chassis slot 1 3 Install the workers in chassis slots 3 4 and 5 4 Power on the chassis 5 Check the chassis and board LEDs to verify that all components are operating normally 6 Chec...

Page 24: ...as the FortiController 5913C management IP address 12 Connect FortiController 5913C front panel interface F1 to the Internet and front panel interface F2 to the internal network The workers see these...

Page 25: ...nto the FortiController 5913C GUI going to Load Balance Status and selecting the Config Master icon beside the primary worker which is always the top entry in the Worker Blade list Using the external...

Page 26: ...e workers in the cluster in a single operation from the worker web based manager The firmware running on all of the workers in the cluster is updated simultaneously 1 Log into the worker web based man...

Page 27: ...ssage Running Slot 6 Status Working Function Active Link Base Up Fabric Up Heartbeat Managment Good Data Good Status Message Running Slot 8 Status Working Function Active Link Base Up Fabric Up Heartb...

Page 28: ...ubleshooting how to articles examples FAQs technical notes and more Visit the Fortinet Knowledge Base at http kb fortinet com Comments on Fortinet technical documentation Send information about any er...

Page 29: ...press or implied except to the extent Fortinet enters a binding written contract signed by Fortinet s General Counsel with a purchaser that expressly warrants that the identified product will perform...

Page 30: ...this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Any changes or modifications...

Reviews: