JSC
“Forteza”
“Forteza
Tribo
‐
M”
operation
manual
13
To
prepare
cable
non
‐
sensitive,
proceed
as
follows:
•
slip
a
seal
for
non
‐
sensitive
cable
over
the
cable;
•
slip
an
ebonite
bush
over
the
cable;
•
remove
the
external
insulation
from
non
‐
sensitive
cable
for
a
distance
of
42
to
44
mm;
•
divide
the
braided
shield
into
strands;
•
apply
the
braided
shield
strands
to
the
ebonite
bush;
•
apply
tinned
‐
wire
serving
except
for
35
to
40
‐
mm
wire
end
left
uncovered;
•
remove
the
central
conductor
insulation
except
for
18
to
20
mm
left
at
the
external
insulation
edge;
•
fold
the
skinned
central
conductor
in
two
layers
and
twist
it
so
that
the
length
of
the
skinned
end
comes
to
12
mm;
•
shape
the
central
conductor
in
compliance.
Be
sure
to
get
a
total
length
of
28
mm;
•
make
sure
the
tail
length
is
6
mm,
minimum.
5.5.
Cables
Termination
in
Adapter
(Fig.
8)
5.5.1.
To
terminate
the
cables
in
the
adapter,
proceed
as
follows
(Fig.
8a):
•
pull
the
spliced
ends
of
the
tribocable
and
non
‐
sensitive
cable
through
the
braided
shield
and
adapter
case
holes;
•
connect
the
spliced
ends
of
the
tribocable
and
non
‐
sensitive
cable
to
the
corresponding
contacts
of
the
terminal
block.
Be
sure
to
insulate
bare
portions
of
the
tribocable
and
non
‐
sensitive
cable
central
conductors
from
accidental
contact
with
the
braided
shield;
•
slip
the
braided
shield
over
the
cable
connector
and
the
bush
so
that
the
edges
of
the
braided
shield
and
the
bush
coincide.
In
so
doing,
make
sure
the
tinned
‐
wire
leads
are
arranged
through
the
centre
of
the
braided
shield
contact;
•
crimp
the
braided
shield
contacts
together
with
the
tinned
wire.
Make
sure
the
diameter
is
not
in
excess
of
16
mm;
•
slip
the
adapter
over
the
braided
shield;
•
put
gaskets
into
the
adapter
case;
•
tighten
the
screws
of
two
clamps
so
that
the
adapter
case
fits
tightly
against
the
cables
(make
sure
the
locations
of
clamps
and
gaskets
coincide).
To
prevent
moisture
ingress
into
the
adapter
use
should
be
made
of
neutral
sealant
applied
at
the
points
of
the
adapter
case
and
gaskets
contact.
5.5.2.
To
terminate
the
cables
in
the
extended
adapter
in
equipping
gates
and
wickets
(Fig.
8b),
proceed
according
to
Item
5.5.1
but
be
sure
first
to
slip
a
required
‐
length
spiral
wrap
hose
over
cable
РК
.
Then
slip
a
seal
over
the
spiral
wrap
hose
end.
Completing
the
cable
termination
be
sure
to
put
the
spiral
wrap
hose
end
together
with
the
seal
into
the
case
and
tighten
it
with
the
third
additional
clamp.
Be
sure
to
tighten
only
non
‐
sensitive
cable
seal,
not
the
spiral
wrap
hose
one.
Summary of Contents for TRIBO-M
Page 1: ...TRIBOELECTRIC GUARD ALARM FOR PERIMETER AREAS FORTEZA TRIBO M Operation manual 2010 ...
Page 22: ...JSC Forteza Forteza Tribo M operation manual 22 ...
Page 23: ...JSC Forteza Forteza Tribo M operation manual 23 ...
Page 24: ...JSC Forteza Forteza Tribo M operation manual 24 ...
Page 25: ...JSC Forteza Forteza Tribo M operation manual 25 ...
Page 26: ...JSC Forteza Forteza Tribo M operation manual 26 ...
Page 27: ...JSC Forteza Forteza Tribo M operation manual 27 ...
Page 28: ...JSC Forteza Forteza Tribo M operation manual 28 ...
Page 29: ...JSC Forteza Forteza Tribo M operation manual 29 ...
Page 30: ...JSC Forteza Forteza Tribo M operation manual 30 ...
Page 31: ...JSC Forteza Forteza Tribo M operation manual 31 ...
Page 32: ...JSC Forteza Forteza Tribo M operation manual 32 ...
Page 33: ...JSC Forteza Forteza Tribo M operation manual 33 ...