FORTEZA JSC
FORTEZA FMC 24 (50m, 100m, 200m)
Please visit our internet sites:
1.
DESCRIPTION AND OPERATION
The present description manual and service instruction contains information about the
operation of the local microwave protective detectors series FMC 24 (50m 100m 200m)
below the detector. In this document there is information required for the correct operation
(use, transportation, storage and maintenance) of the detector.
The following abbreviations are used in the present document:
Tx - transmitter
Rx - receiver.
MK - mounting kit;
1.1. Purpose
1.1.1. The purpose of the sensors is to protect the perimeter sectors and to detect an
intruder crossing this sector at his “full height” or “bent”. An alarm is generated by
breaking the individual point relay contacts. Then it is transmitted on the receiver.
1.1.2. The detector is intended for continuous round-the-clock outdoor operation at an
ambient temperature -40ºC…+60
С and relative humidity up to 98% at the temperature
+35
С.
1.1.3. When the sensor operates with the alarm complex, you can control the sensor
with RS-485 interface.
1.2. Specifications
1.2.1. The recommended length (L) of a sector for modifications:
FMC 24 (200m) – 10…200 m
FMC 24 (100m) – 10…100 m
FMC 24 (50m) – 5…50 m
The detection zone height, h:
FMC 24 (200m)
1,8 m* maximum
FMC 24 (100m)
1,6 m* maximum
FMC 24 (50m)
1,4 m* maximum
The detection zone width, b :
FMC 24 (200m)
2,1 m* maximum
FMC 24 (100m)
1,5 m* maximum
FMC 24 (50m)
1,0 m* maximum
* in the middle of a sector at the maximum length
The cross speed:
0,1 up to10 m/sec
The quantity of the frequency channels
4
Supply voltage
9…30 V