Do some check passages in “problem” places of the detection zone: hollows,
hills, near to barriers, buildings, and trees situated in the detection zone. If it is necessary
change the sensor sensitivity.
2.4.3.5.
We offer to set switchers in position – 10%
and cross the detection zone
in different points. In case if the detector is not generated alarm during the investigator
passage, set first switchers to position
and after that to po 10%
.
Notes. If switcher’s is in position + 10% the detector is not generated alarm during
the investigator passage, please use computer to adjust the sensitivity.
2.4.3.6. When the adjustment is over, it is necessary to close Rx and Tx terminal
covers.
2.4.3.7. After the sensor adjustment it is recommended to carry out its trial operation
for 2…3 days to reveal and eliminate possible errors of mounting and adjustment.
2.5. Software installation and detector adjustment with PC
2.5.1. The computer allows checking the signal level, change sensitivity parameters,
detection zone length, giving a signal, setting some parameters inaccessible for Preliminary
adjustment.
2.5.2. Software installation
2.5.2.1.
You can download the latest version of setup software from our website
download menu
or find it on USB FLASH DRIVE which is
included in detector set.
2.5.2.2.
Connect the sensor to PC with RS 485 with USB, power to the sensor. The
computer determines the type of USB device and installs the driver on COM-port. If the
driver is not installed automatically, the computer asks to install the driver. Follow IIIIIII
You can find driver in Forteza FMC SOFT file.