Running the automatic feeder
67
If visible milk deposits are flushed into the mixer jar during the sponge cleaning process, your
cleaning measures are not sufficient. Do the following:
•
Make sure that sufficient cleaning agent is available.
•
Check whether the concentration of the cleaning agent corresponds to the manufacturer's
recommendations.
•
Check whether the detergent pump is working.
•
Clean more frequently.
You manually set heat exchanger cleaning with a sponge as follows:
1. Have the sponge ball, which comes with your automatic feeder, ready.
2. Choose
> Cleaning > Sponge
to go to the
Clean with sponge
submenu.
3. On the automatic feeder, open the metal plug for the sponge cleaning procedure. (See pic-
tures below)
1
2
1 Metal plug
2 Tappet3
4. Push the sponge ball into the opening using the tappet.
5. Close the metal plug again.
6. Confirm the display message
Sponge inserted?
by choosing
.
Water pushes the sponge through the stainless steel coil of the heat exchanger, removing
tough deposits.
7. Remove the sponge ball from the mixer jar. Clean the sponge ball and store it in a dry place.