Fault Diagnostics / Maintenance
Before any maintenance work is carried out, both electrical and air supplies must be locked in the
OFF position. Only a qualified electrical technician may work on any parts carrying mains voltage.
That person is responsible for ensuring that the machine is in a safe condition before allowing
services to be restored.
Replace a damaged or worn seal
Remove the existing seal with a sharp knife. Remove as much of the original sealant as possible. Using
masking tape, make a frame inside where the seal will go (table) or outside (clamp) squeeze some glue
around the area where the seal is to be placed. Do not be too economical with the glue. Bed down a strip of
silicon seal until it is firmly seated in the glue.
Do not attempt to stretch the rubber seal, it will contract back to its original size before the glue is dry. Cut
the ends at 45 degrees. Continue this process for all 4 sides of the seal. Fill up any gaps in the mitred joints
with glue. Place masking tape over the mitred corners to help keep them firmly positioned until the glue is
dry.
Leave overnight, then remove masking tape and trim any excess glue off with a sharp knife.
We supply a kit comprising the necessary seal and glue for the IMD508
Cleaning
Ensure the inside of the machine and the heater tray is cleared of dust, dirt and debris. Do not allow dirt and
loose particles to build up, particularly on the heater tray.
Service Support
If you are unable to cure any problem relating to your machine, or if you wish to order spare parts please
contact us on the numbers and emails shown on the back cover of this manual stating the model
IMD508
,
the serial number (on the specification plate), and a full description of the fault or parts you need.
Summary of Contents for IMD508
Page 36: ...Manual Formech IMD508 36 Electrical Schematic 1 2 ...
Page 37: ...Manual Formech IMD508 37 Electrical Schematic 3 4 ...
Page 38: ...Manual Formech IMD508 38 Electrical Schematic 5 6 ...
Page 39: ...Manual Formech IMD508 39 Electrical Schematic 7 8 ...
Page 40: ...Manual Formech IMD508 40 Electrical Schematic 9 10 ...
Page 41: ...Manual Formech IMD508 41 Electrical Schematic 11 12 ...
Page 42: ...Manual Formech IMD508 42 Electrical Schematic 13 14 ...
Page 43: ...Manual Formech IMD508 43 Electrical Schematic 15 16 ...
Page 44: ...Manual Formech IMD508 44 Electrical Schematic 17 18 ...
Page 45: ...Manual Formech IMD508 45 Electrical Schematic 19 20 ...
Page 46: ...Manual Formech IMD508 46 Electrical Schematic 21 22 ...
Page 47: ...Manual Formech IMD508 47 Electrical Schematic 23 24 ...
Page 48: ...Manual Formech IMD508 48 Electrical Schematic 25 26 ...
Page 49: ...Manual Formech IMD508 49 Electrical Schematic 27 28 ...
Page 50: ...Manual Formech IMD508 50 Electrical Schematic 29 30 ...
Page 51: ...Manual Formech IMD508 51 Electrical Schematic 31 32 ...
Page 52: ...Manual Formech IMD508 52 Electrical Schematic 33 34 ...