41
1
1. Locate the Allen tools supplied with the Cross Perforation kit.
2. Place the cross perforation tool on a table in the orientation shown below.
3. Remove one guide bolt [C] and spring [D]. Only one side needs to be removed.
WARNING!
All blades are very sharp: use extreme caution. Leather gloves must be worn
whenever handling the blades.
Anvil strip removal / replacement
D
C
A
B
Continued on next page...
NOTE:
Each anvil strip can be used
twice. When perforation is no
longer effective the anvil strip
can be rotated 180 degrees to be
reused.
NOTE:
Before replacing anvil strip decrease perforation depth to avoid causing excess strain
on motor and reducing lifespan of anvil strip. adjustment procedure can be found under
'perforation depth adjustment'.
Summary of Contents for Atlas C350
Page 1: ...Atlas C350 Automatic Air Feed Programmable Folder Creaser OPERATOR MANUAL 10 2021...
Page 6: ...Page intentionally blank...
Page 16: ...16 Page intentionally blank...
Page 37: ...37 1 Page intentionally blank...
Page 46: ...46 1 Page intentionally blank...
Page 56: ...56 1 Page intentionally left blank...
Page 57: ...57 1 Page intentionally left blank...
Page 72: ...72 2 Page intentionally blank...
Page 86: ...86 3 Page intentionally blank...
Page 91: ...91 4 C D E F G H I...